Safety-rated or not? Understand the key differences and what they mean for your application.
Home SICK Sensor Blog LiDAR vs. Safe LiDAR - what's the difference
LiDAR is widely used in industrial applications. Choosing from the many available technologies and device types can be challenging. One key consideration is whether the application requires standard LiDAR or safety-rated LiDAR. Safety-rated LiDAR devices are often referred to as safety laser scanners. But what makes LiDAR safety-rated? And when do you need a safety-rated device?
What is LiDAR
First, let’s tackle a basic definition. LiDAR is an acronym, standing for LIght Detection And Ranging. It operates using the time-of-flight principle, which is well established in industry. We know the speed of light through our atmosphere so that means we can send a pulse of light, bounce it off a target, and measure the amount of time it takes to come back. By halving the total time and multiplying by the speed of light, we know the distance to the target. This is the core of how LiDAR works.
2D LiDAR means that the sensors utilize a method involving a laser beam being directed across a rotating mirror to scan a 2D area. It is also possible to rotate the complete optic system. For a 3D LiDAR, the device contains of further capabilities to create multiple scanning lines, e.g. by using multiple transceiver units or receiver arrays, resulting in a 3D point cloud of the environment.
Safety laser scanners are safety-related LiDAR devices (typically 2D), that are used in various industries and applications to monitor and ensure the safety of people. These devices use LiDAR technology to “scan” an area and when a person or object is detected, a signal is sent to stop the nearby machine or hazard.
What makes LiDAR safe?
But what makes these devices safe? Well, safety laser scanners are specifically designed with safety in mind. Here are three elements that make LiDAR safe.
1. Meeting Safety Standards
A safety laser scanner is considered safe when it meets certain criteria and adheres to specific standards and regulations, such as ISO 13849 and IEC 61496. These standards outline the requirements for safety-related parts of control systems, including the design and performance of safety laser scanners.
Through these standards, performance levels of the devices are determined. Safety laser scanners are categorized according to performance level, which is determined by the level of safety provided. The performance level is assigned based on factors such as the reliability of the electronics of the scanner, its response time, and the ability to detect even dark objects accurately. Historically this has always been Performance Level d, which is used to mitigate risks that could lead to severe injury.
Another important safety standard is IEC TS 62998-1 which is used for the verification of safety-related sensors with new safety functions which are not described by IEC 61496. This can be lower safety levels, safety-related measurement data or new detection principle like 3D perception of persons.
2. Defined Safety Zones
Safety laser scanners define specific safety zones, called protective fields where human presence is not allowed or where machine operation must be modified to prevent hazards. The scanner should accurately detect and monitor these zones, ensuring that safety measures are triggered if any unauthorized entry or intrusion occurs.
They also have a fast response time, typically in the range of milliseconds. This allows them to quickly detect and respond to any safety breaches or potential hazards in real-time. They can trigger appropriate safety measures, such as stopping or slowing down machinery, activating warning signals, or initiating emergency shutdown procedures.
3. Testing and Validation
Safety laser scanners undergo rigorous testing and validation to ensure safety and performance. This includes tests for factors like fault tolerance, resilience to environmental conditions, and adherence to safety standards. Certified safety laser scanners should have documentation, such as a Declaration of Conformity, indicating that they have undergone the necessary testing and meet the specified safety requirements.
Which Type of LiDAR is Right for Your Application
When selecting LiDAR sensors, it is important to consider safety ratings, especially for applications involving potential risks to humans. Both safe and non-safe LiDAR are valuable for the manufacturing industry, but you may not always need to use safety-rated sensors. And sometimes certain applications may require safety-rated LiDAR that you may not expect. It’s important to stay informed and understand when you should use either type. This is almost always done through risk assessments. SICK offers safety services to conduct comprehensive risk assessments.
Safety-Rated LiDAR
Safety-rated LiDARs, often referred to as safety laser scanners, are used indoors and outdoors in manufacturing. Safe LiDAR is often used in mobile and stationary settings, such as applications where there may be significant human interaction with the machine, device, or robot.
Safety-rated sensors comply with norms and standards set by organizations such as the International Electrotechnical Commission (IEC) and The American National Standard Institute (ANSI). The IEC 61496 standard establishes criteria for Electro-Sensitive Protective Equipment (ESPE) construction and testing. ESPE levels are determined based on the associated machinery or process risk within the industry. Similarly, the Safety Integrity Level 2 (SIL2), or ISO 13849-1 standard, specifies the functional safety of LiDAR sensors. SICK offers numerous safety laser scanner options, but two of them are the microScan3 and the nanoScan3.
The microScan3 is built for the protection of stationary and mobile applications with Performance Level d, from simple to complex. With its innovative safeHDDM™ scanning technology, it is highly resistant to dirt, dust, and ambient light. With the ability to simultaneously monitor up to 8 protective fields, it also performs well in applications requiring simultaneous protection of several hazardous areas.
The nanoScan3 combines a compact design with Performance Level d. Its space-saving design suits in mobile robotics applications, but also in stationary applications where space is limited. It delivers high-precision measurement data and provides resistance to light, dust, or dirt. It also has a high level of flexibility with up to 128 freely configurable fields and monitoring cases.
When risks for injury are less severe the TiM-S with Performance Level b is known to be a versatile sensor, which is even more compact than nanoScan3, making it a good match for confined spaces and autonomous carts.
multiScan100-S marks a technological highlight of today’s safety-rated LiDAR sensors. It is a 3D LiDAR sensor rated with Performance Level b (ISO 13849-1) for its hardware and software capabilities and performance class C (IEC 62998) for its detection capabilities. It is possible to safely monitor a 3D volume with several scan layers and use that data to perform a comprehensive 3D safety rated perception of the environment around the sensor. Due to its 3D perception principle and safe multi-echo capabilities, multiScan100-S offers outstanding robustness and detection ranges even under outdoor conditions. For making these valuable features available to a broader range of demanding applications, SICK offers TÜV-certified Safety Application Notes for supporting the integration of multiScan100-S into system approaches with higher safety requirements up to PL d.
LiDAR
In applications where there is no hazard for humans to be expected, non-safety-rated sensors are used. These are also used indoors and outdoors in manufacturing, and although these sensors possess similar capabilities to safety-rated devices, they do not meet safety standards to qualify them as a safety laser scanner. While not considered safety-rated, that does not make these devices unnecessary or dangerous to use.
LiDAR sensors are commonly employed in conventional industrial control systems. These sensors provide the advantage of non-contact detection of actual values at the output of the work process, utilizing the measurement element. Non-safe LiDAR measures in, 2D, and 3D.
2D LiDAR
2D LiDAR utilizes a method involving a laser beam being directed across a rotating mirror, or the complete optical system is rotated, which may seem simple at first glance but requires attention to detail.
Many scanning sensors are designed as coaxial measuring systems, with the emitted beam at the center of the received beam. In this setup, a rotating mirror is used to deflect the beam. All the exceptional properties of laser measurements, including the ability to scan over a wide range and measure even dark objects, still apply in this scenario.
3D LiDAR
To measure space, 3D LiDAR is utilized. Typically, that means several layers are being measured simultaneously.
The multiScan100 3D LiDAR sensor is an example of multilayer LiDAR technology. The sensor generates a 3D point cloud that can be used to detect people and objects. It detects cliffs and overhanging obstacles. This is how it reliably protects mobile robots from accidents and failures. The multiScan100 reliably detects objects, no matter whether they are standing on the ground or projecting into its field of view. This helps it avoid collisions. The sensor always “knows” where a vehicle is.