Miniature photoelectric sensors
W4S-3 Inox Hygiene
WTB4S-3P1262H
1117988
-
Technical details
-
Downloads
-
Accessories
-
Applications
-
Videos
-
Service and Support
-
Customs data
-
- Features
Functional principle Photoelectric proximity sensor Functional principle detail Background suppression Dimensions (W x H x D) 15.25 mm x 63.2 mm x 22.15 mm Housing design Hygiene Housing design (light emission) Rectangular Sensing range max. 4 mm ... 500 mm 1) Sensing range 10 mm ... 350 mm 1) Type of light Visible red light Light source PinPoint LED 2) Light spot size (distance) Ø 6.5 mm (150 mm) Wave length 650 nm Adjustment Single teach-in button Special applications Hygienic and washdown zones - 1) Object with 90% remission (based on standard white, DIN 5033).
- 2) Average service life: 100,000 h at TU = +25 °C.
- Mechanics/electronics
Supply voltage 10 V DC ... 30 V DC 1) Ripple < 5 Vpp 2) Current consumption 30 mA 3) Switching output PNP Output function Complementary Switching mode Light/dark switching Output current Imax. ≤ 100 mA Response time < 0.5 ms 4) Switching frequency 1,000 Hz 5) Connection type Cable, 4-wire, 5 m 6) Mechanical connection M12 adapter thread Cable material PVC Conductor cross section 0.14 mm² Circuit protection A, B, C 7) 8) 9) Protection class III Weight 80 g Housing material Stainless steel, Stainless steel V4A (1.4404, 316L) Optics material Plastic, PMMA Enclosure rating IP66
IP67
IP68
IP69K
Ambient operating temperature –30 °C ... +70 °C 10)
–30 °C ... +60 °C
Ambient temperature, storage –30 °C ... +75 °C UL File No. FDA, UL No. NRKH.E181493 & cUL No. NRKH7.E181493 - 1) Limit values, reverse-polarity protected, operation in short-circuit protected network: max. 8 A.
- 2) May not exceed or fall below Uv tolerances.
- 3) Without load.
- 4) Signal transit time with resistive load.
- 5) With light/dark ratio 1:1.
- 6) Do not bend below 0 °C.
- 7) A = VS connections reverse-polarity protected.
- 8) B = inputs and output reverse-polarity protected.
- 9) C = interference suppression.
- 10) At UV ≤ 24 V and IA < 30 mA.
- Safety-related parameters
MTTFD 1,186 years DCavg 0 % TM (mission time) 20 years
- Classifications
eCl@ss 5.0 27270904 eCl@ss 5.1.4 27270904 eCl@ss 6.0 27270904 eCl@ss 6.2 27270904 eCl@ss 7.0 27270904 eCl@ss 8.0 27270904 eCl@ss 8.1 27270904 eCl@ss 9.0 27270904 eCl@ss 10.0 27270904 eCl@ss 11.0 27270904 eCl@ss 12.0 27270903 ETIM 5.0 EC002719 ETIM 6.0 EC002719 ETIM 7.0 EC002719 ETIM 8.0 EC002719 UNSPSC 16.0901 39121528
-
-
-
-