MultiTask photoelectric sensors
PowerProx
WTT2SL-2P1192
1081626
-
Technical details
-
Downloads
-
Accessories
-
Applications
-
Videos
-
Service and Support
-
Customs data
-
- Features
Functional principle Photoelectric proximity sensor Functional principle detail Background suppression Dimensions (W x H x D) 7.7 mm x 27.5 mm x 13.5 mm Housing design (light emission) Rectangular Sensing range max. 50 mm ... 800 mm 1) Sensing range 50 mm ... 800 mm 1) Type of light Infrared light Light source Laser 2) Light spot size (distance) Ø 10 mm (300 mm) Wave length 940 nm Laser class 1 Adjustment Single teach-in button 3) Special applications Detecting small objects - 1) Object with 6 ... 90 % remission (based on standard white to DIN 5033).
- 2) Average service life: 50,000 h at TU = +25 °C.
- 3) Teach-Offset 15 mm.
- Mechanics/electronics
Supply voltage 10 V DC ... 30 V DC 1) Ripple < 5 Vpp 2) Current consumption 20 mA 3) Switching output PNP 4) Switching mode Light/dark switching Output current Imax. ≤ 50 mA Response time Typ. 90 ms 5) Switching frequency 5 Hz 6) Analog output - Connection type Cable, 4-wire, 2 m 7) Cable material PVC Cable diameter Ø 3 mm Circuit protection A 8)
B 9)
D 10)
Protection class III Housing material Plastic, MABS
ABS
Optics material Plastic, PMMA Enclosure rating IP67 Ambient operating temperature –25 °C ... +50 °C Ambient temperature, storage –40 °C ... +75 °C UL File No. E181493 - 1) Limit values. Operated in short-circuit protected network: max. 8 A.
- 2) May not exceed or fall below Uv tolerances.
- 3) Without load.
- 4) Off-state current IR ≤ 0,6 mA.
- 5) Jitter +- 20 ms.
- 6) With light/dark ratio 1:1.
- 7) Do not bend below 0 °C.
- 8) A = VS connections reverse-polarity protected.
- 9) B = output reverse-polarity protected.
- 10) D = outputs overcurrent and short-circuit protected.
- Safety-related parameters
MTTFD 925 years DCavg 0 %
- Classifications
eCl@ss 5.0 27270904 eCl@ss 5.1.4 27270904 eCl@ss 6.0 27270904 eCl@ss 6.2 27270904 eCl@ss 7.0 27270904 eCl@ss 8.0 27270904 eCl@ss 8.1 27270904 eCl@ss 9.0 27270904 eCl@ss 10.0 27270904 eCl@ss 11.0 27270904 eCl@ss 12.0 27270903 ETIM 5.0 EC002719 ETIM 6.0 EC002719 ETIM 7.0 EC002719 ETIM 8.0 EC002719 UNSPSC 16.0901 39121528
-
-
-
-