In-situ gas analyzers
ZIRKOR302

Your Benefits

  • Automated testing and adjustment with ambient air
  • No expensive test gases required
  • Reignition into the measurement gas not possible because the sensor is located outside the measurement gas
  • Process monitoring even at high temperatures
  • Quick measurement directly in the process for timely control

The exact device specifications and performance data of the product may deviate from the information provided here, and depend on the application in which the product is being used and the relevant customer specifications.

Overview

The ZIRKOR302 in-situ gas analyzer from SICK can be relied upon to measure oxygen quickly even at increased temperatures. Thanks to the flow sensor measurement principle, it does not require expensive test gases – ambient air is sufficient. The analyzer is not an ignition source in the measurement gas due to its safety-related construction. The optional evaluation unit allows you to operate up to three analyzers.

At a glance
  • Innovative flow sensor measurement principle
  • Fixed physical zero point and linear measurement signal
  • All parts in contact with gas are heated
  • Version for high temperatures available
  • Short response time
  • Operation of up to three analyzers via one evaluation unit

Accessories

Spare parts

Applications

Service & Support

Technical overview

 
  • ZIRKOR302 E analyzer unit

    ZIRKOR302 E analyzer unit

    DescriptionAnalyzer with ejector operating with compressed air
    Measured valuesO2
    Performance-tested measurandsO2
    Measurement principlesZirconium dioxide current sensor
    Gas flow rate
    0.5 l/h
    Measuring ranges
    O20 ... 10 Vol.-% / 0 ... 25 Vol.-%
    Certified measuring ranges
    O20 ... 21 Vol.-%
    Response time (t90)
    ≤ 20 s
    With standard gas sampling device, length = 1 m
    Zero point drift
    ≤ 0.2 Vol.-%: within the maintenance interval
    Reference point drift
    ≤ 0.2 Vol.-%: within the maintenance interval
    Process temperature
    Stainless steel probe0 °C ... +700 °C
    Inconel probe0 °C ... +950 °C
    Ceramics probe0 °C ... +1,400 °C
    Process pressure
    700 hPa ... 1,100 hPa
    Process gas humidity
    Non-condensing
    Ambient temperature
    –20 °C ... +55 °C
    Storage temperature
    –40 °C ... +85 °C
    Conformities

    Approved for plants requiring approval

    2001/80/EC (13. BImSchV)

    2000/76/EC (17. BImSchV)

    27. BImSchV

    EN 14181

    Electrical safetyCE
    Enclosure rating
    IP65 / NEMA 4x
    Analog outputs1 output:
    0/4 ... 20 mA, 800 Ω
    0 ... 10 V
    Potential-free; extendible by an additional I/O module
    Digital outputs4 relay contacts:
    48 V AC, 1 A, 30 W / 48 V DC, 1 A, 60 W
    Option
    Digital inputs4 inputs:
    + 24 V
    Option
    Indication
    LC display
    Input

    Functional keys

    Arrow keys

    OperationMenu-driven operation via LC-display and membrane keyboard
    Dimensions (W x H x D)
    See dimensional drawings
    Weight
    27 kg
    With standard gas sampling device, length = 1 m
    With heating for gas sampling device, additional4 kg ... 6 kg
    Material in contact with mediaStainless steel 1.4571
    Power supply
    Voltage115 V AC, ± 10 %
    230 V AC, ± 10 %
    Frequency48 ... 62 Hz
    Power consumption≤ 250 VA
    Auxiliaries
    Compressed air4 ... 6 bar; particle size max. 1 µm; oil content max. 0.1 mg/m³; pressure dew point max. –30 °C
    Corrective functionsAutomatic testing and adjustment with ambient air
    Integrated componentsSample gas pump
  • ZIRKOR302 P analyzer unit

    ZIRKOR302 P analyzer unit

    DescriptionAnalyzer with integrated sample gas pump
    Measured valuesO2
    Performance-tested measurandsO2
    Measurement principlesZirconium dioxide current sensor
    Gas flow rate
    0.5 l/h
    Measuring ranges
    O20 ... 10 Vol.-% / 0 ... 25 Vol.-%
    Certified measuring ranges
    O20 ... 21 Vol.-%
    Response time (t90)
    ≤ 20 s
    With standard gas sampling device, length = 1 m
    Zero point drift
    ≤ 0.2 Vol.-%: within the maintenance interval
    Reference point drift
    ≤ 0.2 Vol.-%: within the maintenance interval
    Process temperature
    Stainless steel probe0 °C ... +700 °C
    Inconel probe0 °C ... +950 °C
    Ceramics probe0 °C ... +1,400 °C
    Process pressure
    700 hPa ... 1,100 hPa
    Process gas humidity
    Non-condensing
    Ambient temperature
    –20 °C ... +55 °C
    Storage temperature
    –40 °C ... +85 °C
    Conformities

    Approved for plants requiring approval

    2001/80/EC (13. BImSchV)

    2000/76/EC (17. BImSchV)

    27. BImSchV

    EN 14181

    Electrical safetyCE
    Enclosure rating
    IP65 / NEMA 4x
    Analog outputs1 output:
    0/4 ... 20 mA, 800 Ω
    0 ... 10 V
    Potential-free; extendible by an additional I/O module
    Digital outputs4 relay contacts:
    48 V AC, 1 A, 30 W / 48 V DC, 1 A, 60 W
    Option
    Digital inputs4 inputs:
    + 24 V
    Option
    Indication
    LC display
    Input

    Functional keys

    Arrow keys

    OperationMenu-driven operation via LC-display and membrane keyboard
    Dimensions (W x H x D)
    See dimensional drawings
    Weight
    27 kg
    With standard gas sampling device, length = 1 m
    With heating for gas sampling device, additional4 kg ... 6 kg
    Material in contact with mediaStainless steel 1.4571
    Power supply
    Voltage115 V AC, ± 10 %
    230 V AC, ± 10 %
    Frequency48 ... 62 Hz
    Power consumption≤ 250 VA
    Corrective functionsAutomatic testing and adjustment with ambient air
    Integrated componentsSample gas pump
  • ZIRKOR302 control unit; sheet metal housing

    ZIRKOR302 control unit; sheet metal housing

    DescriptionThe control unit serves as the human machine interface and is responsible for data processing and output as well as control and monitoring functions.
    Enclosure rating
    IP65 / NEMA 4x
    Analog outputs3 outputs:
    0/4 ... 20 mA, 500 Ω
    Electrically isolated; one measured value output per connected analyzer
    Digital outputs3 relay contacts:
    48 V AC, 1 A, 60 W / 48 V DC, 1 A, 30 W
    Digital inputs3 inputs:
    24 V
    Preset for failure, maintenance and functional control
    Serial
    Type of fieldbus integrationRS-232
    FunctionConnection to SOPAS ET software
    CAN bus
    FunctionInternal system bus
    Indication
    LC display
    Status LEDs: “Power,” “Failure,” and “Maintenance request”
    Input

    Arrow keys

    Functional keys

    OperationMenu-driven operation via LC-display and membrane keyboard
    ModelSteel sheet enclosure
    Dimensions (W x H x D)
    200 mm x 346 mm x 97.5 mm
    Weight
    4 kg
    Power supply
    Voltage115 V AC, ± 10 %
    230 V AC, ± 10 %
    Frequency50 Hz / 60 Hz
    Power consumption≤ 50 VA
    Recommended pre-fuse10 A
  • ZIRKOR302 control unit; cast metal housing

    ZIRKOR302 control unit; cast metal housing

    DescriptionThe control unit serves as the human machine interface and is responsible for data processing and output as well as control and monitoring functions.
    Enclosure rating
    IP67 / NEMA 4x
    Analog outputs3 outputs:
    0/4 ... 20 mA, 500 Ω
    Electrically isolated; one measured value output per connected analyzer
    Digital outputs3 relay contacts:
    48 V AC, 1 A, 60 W / 48 V DC, 1 A, 30 W
    Preset for failure, maintenance and functional control
    Digital inputs3 inputs:
    24 V
    Serial
    Type of fieldbus integrationRS-232
    FunctionConnection to SOPAS ET software
    CAN bus
    FunctionInternal system bus
    Indication
    LC display
    Status LEDs: “Power,” “Failure,” and “Maintenance request”
    Input

    Arrow keys

    Functional keys

    OperationMenu-driven operation via LC-display and membrane keyboard
    ModelCast metal enclosure
    Dimensions (W x H x D)
    289 mm x 370 mm x 138 mm
    Weight
    4 kg
    Power supply
    Voltage115 V AC, ± 10 %
    230 V AC, ± 10 %
    Frequency50 Hz / 60 Hz
    Power consumption≤ 50 VA
    Recommended pre-fuse10 A
All technical data can be found accompanying the individual product

Downloads