Your Benefits
- Easy installation, commissioning, and operation
- Measurement independent of gas velocity, humidity and particle charge
- Approved according to EN 15267
- Low maintenance due to self-monitoring



The DUSTHUNTER SB100 is a type-approved measuring device for dust at very low to medium concentrations in challenging applications, e. g., in hot or corrosive gases. The measurement is based on the backward scattering of light. Installation is from one side only. Two different penetration depths are possible. Automated compensation of background radiation, therefore no light absorber required. An automated check of the zero and reference point as well as a contamination check are on board in the device.
Please note: The exact device specifications and performance data of the product may deviate from the information provided here, and depend on the application in which the product is being used and the relevant customer specifications.
Measured values | Scattered light intensity, dust concentration (after gravimetric comparison measurement) | ||||||
Performance-tested measurands | Scattered light intensity | ||||||
Measurement principles | Scattered light backward | ||||||
| |||||||
| |||||||
| |||||||
| |||||||
| |||||||
Conformities | Approved for plants requiring approval 2001/80/EC (13. BImSchV) 2000/76/EC (17. BImSchV) 27. BImSchV TA-Luft (Prevention of Air Pollution) EN 15267 EN 14181 MCERTS 2010/75/EU | ||||||
Electrical safety | CE | ||||||
Test functions | Automatic self-test (linearity, contamination, drift, aging) Contamination limit values: warning at 20%, fault at 30% Manual linearity test with reference filter |
| |||||||||
| |||||||||
| |||||||||
| |||||||||
| |||||||||
Electrical safety | CE | ||||||||
| |||||||||
| |||||||||
| |||||||||
|
Description | Unit to control the system components and to evaluate and output the data provided by them | ||||||||||
| |||||||||||
Electrical safety | CE | ||||||||||
| |||||||||||
Analog outputs | 3 outputs: 0/2/4 ... 20 mA, 750 Ω Electrically isolated; two additional outputs if using I/O modules (option) | ||||||||||
Analog inputs | 2 inputs: 0 ... 20 mA Not electrically isolated; two additional inputs if using I/O modules (option) | ||||||||||
Digital outputs | 5 relay contacts: 48 V, 1 A Potential-free; for status signals | ||||||||||
Digital inputs | 4 potential-free contacts | ||||||||||
| |||||||||||
| |||||||||||
| |||||||||||
| |||||||||||
Operation | Via LC-display or software SOPAS ET | ||||||||||
| |||||||||||
| |||||||||||
| |||||||||||
Options | Interface module(s) I/O module(s) |
Description | Unit to control the system components and to evaluate and output the data provided by them. With integrated purge air unit. | ||||||||||
| |||||||||||
| |||||||||||
Electrical safety | CE | ||||||||||
| |||||||||||
Analog outputs | 3 outputs: 0/2/4 ... 20 mA, 750 Ω Electrically isolated; two additional outputs if using I/O modules (option) | ||||||||||
Analog inputs | 2 inputs: 0 ... 20 mA Not electrically isolated; two additional inputs if using I/O modules (option) | ||||||||||
Digital outputs | 5 relay contacts: 48 V, 1 A Potential-free; for status signals | ||||||||||
Digital inputs | 4 potential-free contacts | ||||||||||
| |||||||||||
| |||||||||||
| |||||||||||
| |||||||||||
Operation | Via LC-display or software SOPAS ET | ||||||||||
| |||||||||||
| |||||||||||
| |||||||||||
Options | Interface module(s) I/O module(s) |
Description | Unit to provide dust-free air for flushing of optical surfaces | ||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||
Electrical safety | CE | ||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||
Test functions | Pressure switch (switching point –35 hPa) | ||||||||||||||||||||||||||||||
Integrated components | 2-step air filter, type Europiclon, dust capacity 200 g |