Contact
Feedback

FLOWSIC100 Flare

Reliable gas flow measurement in flare gas applications

  • At a glance
    • High-resolution measurement and short response time
    • Innovative sensor design for very high gas velocities
    • Optimum signal transmission even under atmospheric pressure
    • Remote installation of the control unit up to 1,000 m away
    • Single and multiple path meter configuration, optional probe type
    • Field repeatable check procedure of factory zero flow test
    • Check cycle for automatic self-diagnosis / signal optimization
    Your Benefits
    • Reliable process control by accurate measurement near to zero flow readings
    • High measurement availability also under emergency plant operation conditions with high gas velocities up to 120 m/s
    • Cost saving by remote installation of control unit in safe area
    • System solution to serve three different flare measurements with a single control unit
    • Cost saving by minimized installation using single probe version FLOWSIC100 EX-PR
    • Securing optimal meter performance by continuous monitoring of meter function and extended field diagnostic capabilities
    FLOWSIC100 Flare
    Reliable gas flow measurement in flare gas applications

    The FLOWSIC100 Flare product family is characterized by a unique flow-optimized sensor design. This innovative design reduces flow noise and signal drift at very high gas velocities to a minimum. Modern signal processing and highly efficient transducers result in high time resolution of the signal and, therefore, accurate measurement, even at very low gas flow rates.

    The standard configuration of the system consists of two sender/receiver units or a measuring probe and the MCUP control unit. The MCUP is used for signal input and output, to calculate reference values (standardization), molecular weight, and mass flow, and for the acquisition of gas volume. It also serves as a user-friendly LCD interface.

    • Technical data overview
      Measured valuesGas velocity, gas temperature, gas volume and mass, Mass flow rate, molecular weight, volumetric flow, a. c., volumetric flow s. c., sound velocity
      Hazardous area

      1G

      2G

      3G

      Class I Division 1

      Class I Division 2

      Ga

      Gb

      Gc

      Measuring rangesMeasuring ranges depend on nominal pipe size and gas composition
      Gas temperature

      Standard: –70 °C ... +180 °C

      High-temperature Zone 1: –70 °C ... +280 °C

      High-temperature Zone 2: –70 °C ... +260 °C

      Low temperature: –196 °C ... +100 °C
      Not for FLOWSIC100 EX/EX-RE Zone 1 and Class I, Division 1

      Operating pressure

      –0.5 bar (g) ... 16 bar (g)

      FLOWSIC100 EX-S 90°: –0.5 bar (g) ... 19 bar (g)

      Nominal pipe size4 ″ ... 72 ″
      Depending on gas composition and device version
      Enclosure rating

      FLSE100 sender/receiver unit (ATEX zone 1): IP65, IP67

      FLSE100 sender/receiver unit (ATEX zone 2): IP65

      FLSE100 sender/receiver unit (CSA class I): depending on device version

      MCUP control unit: IP66

      MCUP control unit (19-inch version): IP20

      MCUP control unit (Ex zone 1): IP66

      MCUP control unit (Ex zone 2/Division 2): Enclosure type 4, IP66

      USB
      FunctionConnection to SOPAS ET software
      Serial
      Type of fieldbus integration

      RS-232

      RS-485

      Function

      Connection to SOPAS ET software

      Internal system bus

      Ethernet
      Type of fieldbus integrationVia optional interface module
      Modbus
      Type of fieldbus integration

      ASCII RS-485 (via optional interface module)

      RTU RS-485 (via optional interface module)

      TCP (via optional interface module)

      HART
      Type of fieldbus integrationVia optional interface module
      PROFIBUS DP
      Type of fieldbus integrationVia optional interface module
      Foundation Fieldbus
      Type of fieldbus integrationVia optional interface module
The exact device specifications and performance data of the product may deviate from the information provided here, and depend on the application in which the product is being used and the relevant customer specifications.
In accordance with Article 2 (4), this product does not fall within the scope of RoHS directive 2011/65/EU and is also not designed for use in products which fall within the scope of this directive. You can find additional information in the product information.