Contact
Feedback

You searched for "hygienic level sensors"

39 results:

Result 1 - 24 out of 39

Exact level measurement in heavily foaming media - no problem for the LFP Inox level sensor. The measuring principle of guided radar provides for utmost reliability; the hygiene-level design of the... Read on
Pieces of plastic in chocolate bars, bacterial contamination of cream cheese, falsely declared ingredients in pasta-based ready meals – a food product may be recalled for any number of reasons. As... Read on
Not all publicity is good publicity – particularly the publicity found on www.lebensmittelwarnung.de. The website of the federal states and the Federal Office of Consumer Protection and Food Safety... Read on
The clean solution
  • Level measurement in hygienic applications
  • Rod probe can be cut to length manually up to 4,000 mm long with Ra ≤ 0.8 µm
  • Process temperature up to 180 °C, process pressure up to 16 bar
  • CIP/SIP-resistant
  • High enclosure rating: IP 67 and IP 69, autoclavable
  • Interchangeable hygienic process connections
  • 3 in 1: combines display, analog output, and binary output
  • Remote amplifier with process connection
  • IO-Link 1.1
Compare now
Select
Hygiene-compliant sensor solutions for a wide variety of requirements
The new fluid sensors from SICK, such as the DOSIC® flow sensor, offer calibration-free measurements no matter which medium they are used in, ensuring a high level of flexibility. Plants do not have... Read on
Selecting the right method and appropriate device for the flow measurement generally involves a time-consuming and resource-intensive consideration of the advantages and disadvantages of the different... Read on
The intelligent limit switch for all kinds of liquids
  • Commissioning without container filling or medium calibration
  • Immune to deposit formation
  • Process temperature up to 150 °C
  • Two electrical output versions and IO-Link available
  • Pipe extension up to 1,200 mm
  • Hygienic designs with polished surface, CIP- and SIP-capable
  • Housing made of 316L stainless steel
  • Very high repeatability
Compare now
Select
Flexible and straightforward point level measurement - the economic solution
  • Capacitive level switch based on electrical impedance spectroscopy
  • Plug and play: preset to watery media
  • Process temperature: −20 °C ... +100 °C (+135 °C for 1 h)
  • Process pressure: −1 bar ... 25 bar
  • Two digital PNP outputs
  • Enclosure ratings IP66, IP67 and IP69
  • Ideal for hygienic applications (easy to clean, EHEDG, 3A, EG1935/2004, FDA, CIP- and SIP-capable, hygienic adapter available)
Compare now
Select
Flexible and robust – Tuning Forks for all kinds of liquids
  • Choice of various housing materials and electrical output signals
  • Commissioning without filling
  • Process temperature up to 250 °C
  • Immune to deposit formation
  • Very high repeatability
  • Hygienic designs according to EHEDG and FDA, compatible for CIP and SIP
  • ATEX approval available
  • Tube extension up to 6 m in length

Compare now
Select

Type: IO-Link function block

Name: Function Block Factory

Software category: Function block

Size: 1.00 KB

Product family: L25, L26, Function Block Factory, OD1000, ...

Details
Open
SICK presents new digital solutions portfolio for accessing sensor data via AppSpace and IntegrationSpace MINNEAPOLIS, MINN., JUNE 2020 – Sensor technology, SensorApps, and the Cloud –... Read on
Photoelectric proximity sensors from various product families, fiber-optic sensors, inductive proximity sensors, laser sensors, and safety locking devices - SICK sensor technology plays a crucial role... Read on
Now in the leaders yellow jersey: Presenting the new RE1 and RE2 safety switches, SICK complements its portfolio with two product families that open up a great variety of possibilities in conjunction with... Read on
Transparent plastic packaging, bottles made of glass or PET, ampoules, pipettes, flat, tubular, and hollow glass, films for securing loads on pallets: In many manufacturing processes, automators must cope... Read on
IO-Link is the world’s first standardized IO technology (IEC 61131-9) for communicating with sensors and actuators.

Part number: 8020881

Title: Non-risk declaration

Release date: Feb 10, 2017

Size: 358.00 KB

Download

Type: Product segment overview

Part number: 8018140

Title: FLUID SENSORS Overview of the Products

Release date: Mar 1, 2020

Size: 2.31 MB

Details

Download

Type: Operating instructions

Part number: 8012595

Title: LFV 200 Hygienic version

Release date: Jul 29, 2013

Size: 1.00 MB

Download

Type: Special information

Part number: 8020518

Title: SMART SENSORS SUPPLIERS OF INFORMATION FOR INDUSTRY 4.0

Release date: Sep 27, 2019

Size: 2.44 MB

Details

Download
The L29 single-beam photoelectric safety switch, developed especially for the packaging manufacturer MULTIVAC, stops dangerous movements safely if someone reaches into the forming station in a thermoforming... Read on
Reliable function under the toughest conditions - that is the promise from the heavy-duty sensors from SICK. Different product families are available depending on the individual application requirements;... Read on
What use are hygienic sensors if their mounting components provide a breeding ground for germs? None whatsoever! That's why SICK has designed the mounting system in line with hygienic design. No build-up... Read on

Result 1 - 24 out of 39

TOP