Contact
Feedback

Lector63x

Intelligent. Flexible. Intuitive.
  • At a glance
    • Code reader with 2-megapixel sensor
    • Flexible optics and filter design
    • Integrated, replaceable high-power illumination
    • Intuitive user interface, with flexible result string with code analysis options
    • Function buttons, aiming laser, acoustic feedback signal, and green feedback LED
    • microSD memory card
    Your Benefits
    • High-resolution sensor and intelligent processing ensure outstanding reading performance, even under difficult reading conditions
    • Flexible optical design and high-power illumination enable small codes to be read at high speeds or in applications with a large reading distance
    • Fast, straightforward commissioning thanks to the intuitive user interface, function button for rapid device setup, integrated illumination and aiming laser
    • Direct results monitoring thanks to acoustic signal and colored feedback spot on the object
    • Few machine downtimes in the event of faults on the production line, thanks to straightforward cloning function using microSD memory card
    Lector63x
    Intelligent. Flexible. Intuitive.

    The Lector63x is a flexible image-based code reader. With its high image resolution, compact housing and exchangeable optical design it is well equipped for a variety of needs. It can easily be used for small codes, in high production speeds or for long-range identification. The Lector63x is easy to handle: quick optical exchange, intuitive user interface, aiming laser, beeper, LED feedback and MicroSD card – simplifying setup, operation and maintenance!

    • Technical data overview
      FocusAdjustable focus
      Scanning frequency≤ 50 Hz, With resolution of 1.3 megapixels, at 1.9 megapixels resolution
      Code resolution≥ 0.1 mm 1)
      Reading distance50 mm ... 2,200 mm
      Serial (RS-232, RS-422)
      USB✔ , USB 2.0
      Ethernet✔ , TCP/IP, FTP (image transmission), EtherNet/IP™, PROFINET (optional over external fieldbus module CDF600-2)
      CAN bus✔ , CSN (SICK CAN Sensor Network)
      PROFIBUS DP✔ , Optional over external fieldbus module (CDF600-2)
      DeviceNet™
      Weight430 g ... 590 g
      • 1) Depends on lens used, for details see field of view diagram.
Please select your products
Show all Hide all
Filter by:

17 results:

Result 1 - 17 out of 17

1075881
Lector63x
2D vision
  • Sensor resolution: 1,600 px x 1,200 px
  • Lens: Exchangeable (C-mount), to be ordered separately as an accessory
  • Reading distance: 50 mm ... 2,200 mm (depends on lens used, for details see field of view diagram)
  • Code resolution: ≥ 0.1 mm (depends on lens used, for details see field of view diagram)
  • Details
  • Compare now
1067380
Lector63x
2D vision
  • Sensor resolution: 1,600 px x 1,200 px
  • Lens: Exchangeable (S-mount), to be ordered separately as accessory
  • Reading distance: 50 mm ... 2,200 mm (depends on lens used, for details see field of view diagram)
  • Code resolution: ≥ 0.1 mm (depends on lens used, for details see field of view diagram)
  • Details
  • Compare now
1074079
Lector63x
2D vision
  • Sensor resolution: 1,600 px x 1,200 px
  • Lens: C-mount, focal length 12 mm, aperture 8
  • Reading distance: 50 mm ... 2,200 mm (depends on lens used, for details see field of view diagram)
  • Code resolution: ≥ 0.1 mm (depends on lens used, for details see field of view diagram)
  • Details
  • Compare now
1074080
Lector63x
2D vision
  • Sensor resolution: 1,600 px x 1,200 px
  • Lens: C-mount, focal length 16 mm, aperture 8
  • Reading distance: 50 mm ... 2,200 mm (depends on lens used, for details see field of view diagram)
  • Code resolution: ≥ 0.1 mm (depends on lens used, for details see field of view diagram)
  • Details
  • Compare now
1074081
Lector63x
2D vision
  • Sensor resolution: 1,600 px x 1,200 px
  • Lens: C-mount, focal length 25 mm, aperture 8
  • Reading distance: 50 mm ... 2,200 mm (depends on lens used, for details see field of view diagram)
  • Code resolution: ≥ 0.1 mm (depends on lens used, for details see field of view diagram)
  • Details
  • Compare now
1074299
Lector63x
2D vision
  • Sensor resolution: 1,600 px x 1,200 px
  • Lens: S-mount, focal length 9.6 mm, aperture 8
  • Reading distance: 50 mm ... 2,200 mm (depends on lens used, for details see field of view diagram)
  • Code resolution: ≥ 0.1 mm (depends on lens used, for details see field of view diagram)
  • Details
  • Compare now
1074301
Lector63x
2D vision
  • Sensor resolution: 1,600 px x 1,200 px
  • Lens: S-mount, focal length 25 mm, aperture 8
  • Reading distance: 50 mm ... 2,200 mm (depends on lens used, for details see field of view diagram)
  • Code resolution: ≥ 0.1 mm (depends on lens used, for details see field of view diagram)
  • Details
  • Compare now
1078472
Lector63x
2D vision
  • Sensor resolution: 1,280 px x 1,024 px
  • Lens: Exchangeable (S-mount), to be ordered separately as accessory
  • Reading distance: 50 mm ... 2,200 mm (depends on lens used, for details see field of view diagram)
  • Code resolution: ≥ 0.1 mm (depends on lens used, for details see field of view diagram)
  • Details
  • Compare now
1078473
Lector63x
2D vision
  • Sensor resolution: 1,280 px x 1,024 px
  • Lens: Exchangeable (C-mount), to be ordered separately as an accessory
  • Reading distance: 50 mm ... 2,200 mm (depends on lens used, for details see field of view diagram)
  • Code resolution: ≥ 0.1 mm (depends on lens used, for details see field of view diagram)
  • Details
  • Compare now
1080075
Lector63x
2D vision
  • Sensor resolution: 1,280 px x 1,024 px
  • Lens: C-mount, focal length 12 mm, aperture 8
  • Reading distance: 50 mm ... 2,200 mm (depends on lens used, for details see field of view diagram)
  • Code resolution: ≥ 0.1 mm (depends on lens used, for details see field of view diagram)
  • Details
  • Compare now
1080076
Lector63x
2D vision
  • Sensor resolution: 1,280 px x 1,024 px
  • Lens: C-mount, focal length 16 mm, aperture 8
  • Reading distance: 50 mm ... 2,200 mm (depends on lens used, for details see field of view diagram)
  • Code resolution: ≥ 0.1 mm (depends on lens used, for details see field of view diagram)
  • Details
  • Compare now
1080077
Lector63x
2D vision
  • Sensor resolution: 1,280 px x 1,024 px
  • Lens: C-mount, focal length 25 mm, aperture 8
  • Reading distance: 50 mm ... 2,200 mm (depends on lens used, for details see field of view diagram)
  • Code resolution: ≥ 0.1 mm (depends on lens used, for details see field of view diagram)
  • Details
  • Compare now
1082394
Lector63x
2D vision
  • Sensor resolution: 1,280 px x 1,024 px
  • Lens: Exchangeable (C-mount), to be ordered separately as an accessory
  • Reading distance: 50 mm ... 2,200 mm (depends on lens used, for details see field of view diagram)
  • Code resolution: ≥ 0.1 mm (depends on lens used, for details see field of view diagram)
  • Details
  • Compare now
1082396
Lector63x
2D vision
  • Sensor resolution: 1,600 px x 1,200 px
  • Lens: Exchangeable (C-mount), to be ordered separately as an accessory
  • Reading distance: 50 mm ... 2,200 mm (depends on lens used, for details see field of view diagram)
  • Code resolution: ≥ 0.1 mm (depends on lens used, for details see field of view diagram)
  • Details
  • Compare now
1074300
Lector63x
2D vision
  • Sensor resolution: 1,600 px x 1,200 px
  • Lens: S-mount, focal length 17.5 mm, aperture 8
  • Reading distance: 50 mm ... 2,200 mm (depends on lens used, for details see field of view diagram)
  • Code resolution: ≥ 0.1 mm (depends on lens used, for details see field of view diagram)
  • Details
  • Compare now
1082395
Lector63x
2D vision
  • Sensor resolution: 1,280 px x 1,024 px
  • Lens: Exchangeable (S-mount), to be ordered separately as accessory
  • Reading distance: 50 mm ... 2,200 mm (depends on lens used, for details see field of view diagram)
  • Code resolution: ≥ 0.1 mm (depends on lens used, for details see field of view diagram)
  • Details
  • Compare now
1082397
Lector63x
2D vision
  • Sensor resolution: 1,600 px x 1,200 px
  • Lens: Exchangeable (S-mount), to be ordered separately as accessory
  • Reading distance: 50 mm ... 2,200 mm (depends on lens used, for details see field of view diagram)
  • Code resolution: ≥ 0.1 mm (depends on lens used, for details see field of view diagram)
  • Details
  • Compare now

Result 1 - 17 out of 17

4Dpro - The flexibility you need 

  • Standardized connectivity
  • Common user interface
  • Common set of accessories
Learn more
TOP