Technical details
-
Downloads
-
Accessories
-
Videos
-
Service and Support
-
Customs data
-
- Features
Sensor/ detection principle Photoelectric retro-reflective sensor, autocollimation Dimensions (W x H x D) 15.25 mm x 63.2 mm x 22.15 mm Housing design Hygiene Housing design (light emission) Rectangular Sensing range max. 0 m ... 5 m 1) Sensing range 0 m ... 3 m 1) Type of light Visible red light Light source PinPoint LED 2) Light spot size (distance) Ø 45 mm (1.5 m) Wave length 650 nm Adjustment Single teach-in button AutoAdapt ✔ Special applications Hygienic and washdown zones, Detecting transparent objects - 1) Reflector PL80A.
- 2) Average service life: 100,000 h at TU = +25 °C.
- Mechanics/electronics
Supply voltage 10 V DC ... 30 V DC 1) Ripple < 5 Vpp 2) Current consumption 30 mA 3) Switching output PNP Switching mode Light/dark switching Output current Imax. ≤ 100 mA Response time < 0.5 ms 4) Switching frequency 1,000 Hz 5) Attenuation along light beam > 8 % Connection type Male connector M8, 4-pin 6) Mechanical connection D12 adapter shaft Circuit protection A, B, C 7) 8) 9) Protection class III Weight 140 g Polarisation filter ✔ Housing material Stainless steel, Stainless steel V4A (1.4404, 316L) Optics material Plastic, PMMA Enclosure rating IP66
IP67
IP68
IP69K
Special feature Detecting transparent objects, D12 adapter shaft Ambient operating temperature –30 °C ... +70 °C 10)
–30 °C ... +60 °C
Ambient temperature, storage –30 °C ... +75 °C UL File No. FDA, UL No. NRKH.E181493 & cUL No. NRKH7.E181493 - 1) Limit values, reverse-polarity protected, operation in short-circuit protected network: max. 8 A.
- 2) May not exceed or fall below Uv tolerances.
- 3) Without load.
- 4) Signal transit time with resistive load.
- 5) With light/dark ratio 1:1.
- 6) Max. tightening torque: 0.6 Nm.
- 7) A = VS connections reverse-polarity protected.
- 8) B = inputs and output reverse-polarity protected.
- 9) C = interference suppression.
- 10) At UV ≤ 24 V and IA < 30 mA.
- Safety-related parameters
MTTFD 1,222 years DCavg 0 %
- Communication interface
Communication interface IO-Link V1.1 Communication Interface detail COM2 (38,4 kBaud) Cycle time 2.3 ms Process data length 16 Bit Process data structure Bit 0 = switching signal QL1
Bit 1 = switching signal QL2
Bit 2 ... 15 = empty
VendorID 26 DeviceID HEX 0x8001CE DeviceID DEC 8389070
- Smart Task
Smart Task name Base logics Logic function Direct
AND
OR
WINDOW
Hysteresis
Timer function Deactivated
On delay
Off delay
ON and OFF delay
Impulse (one shot)
Inverter Yes Switching frequency SIO Direct: 1000 Hz
SIO Logic: 1000 Hz
IOL: 900 Hz
Response time SIO Direct: 300 µs ... 450 µs 1)
SIO Logic: 500 µs ... 600 µs 2)
IOL: 500 µs ... 900 µs 3)
Repeatability SIO Direct: 150 µs 1)
SIO Logic: 150 µs 2)
IOL: 400 µs 3)
Switching signal Switching signal QL1 Switching output Switching signal QL2 Switching output - 1) SIO Direct: sensor operation in standard I/O mode without IO-Link communication and without using internal sensor logic or time parameters (set to "direct"/"deactivated").
- 2) SIO Logic: Sensor operation in standard I/O mode without IO-Link communication. Sensor-internal logic or timing parameters plus Automation Functions used.
- 3) IOL: Sensor operation with full IO-Link communication and usage of logic, timing and Automation Function parameters.
- Classifications
ECl@ss 5.0 27270902 ECl@ss 5.1.4 27270902 ECl@ss 6.0 27270902 ECl@ss 6.2 27270902 ECl@ss 7.0 27270902 ECl@ss 8.0 27270902 ECl@ss 8.1 27270902 ECl@ss 9.0 27270902 ECl@ss 10.0 27270902 ECl@ss 11.0 27270902 ETIM 5.0 EC002717 ETIM 6.0 EC002717 ETIM 7.0 EC002717 ETIM 8.0 EC002717 UNSPSC 16.0901 39121528
-
-
-