- Home
- Product portfolio
- Fluid sensors
- Level sensors
- LFP Inox
- LFP1000-G1NMB
- Home
- Product portfolio
- Fluid sensors
- Level sensors
- LFP Inox
- LFP1000-G1NMB
Level sensors
LFP Inox / TDR sensor
LFP1000-G1NMB
1052075
-
Technical details
-
Downloads
-
Accessories
-
Videos
-
Service and Support
-
Customs data
-
- Features
Medium Fluids Measurement Switch, Continuous Design Standard Probe length 1,000 mm Process pressure –1 bar ... 16 bar Process temperature –20 °C ... +150 °C UL approval ✔ RoHS certificate ✔ IO-Link ✔ EHEDG approval ✔
- Performance
Accuracy of sensor element ± 5 mm Reproducibility ≤ 2 mm Resolution < 2 mm Response time < 400 ms 1) Dielectricity constant ≥ 5 for rod probe
≥ 1.8 with coaxial tube
Conductivity No limitation Deactivated area at process connection 25 mm 2) Deactivated area at end of probe ≥ 10 mm 3) MTTF 194.3 years (EN ISO 13849-1) - 1) Dependent on measuring mode (high speed < 400 ms, high accuracy < 2,800 ms).
- 2) With parameterized container with water under reference conditions, otherwise 40 mm.
- 3) With water under reference conditions.
- Electronics
Supply voltage 12 V DC ... 30 V DC 1) Power consumption ≤ 75 mA at 24 V DC without output load Initialization time ≤ 2 s Protection class III Connection type Round connector M12 x 1, 5-pin Output signal 1 x PNP + 1 x PNP/NPN + 4 mA ... 20 mA / 0 V ... 10 V Output load 4 mA ... 20 mA < 500 Ohm at Uv > 13,5 V, 4 mA ... 20 mA < 400 Ohm at Uv > 12 V, 0 V ... 10 V > 750 Ohm at Uv 14 ≥ V Hysteresis Min. 2 mm, free adjustable Signal voltage HIGH Vs - 2 V Signal voltage LOW ≤ 2 V Output current < 100 mA Inductive load < 1 H Capacitive load < 100 nF Enclosure rating IP67: EN 60529, IP69K: ISO 20653 Temperature drift < 0.1 mm/K Lower signal level 3.8 mA ... 4 mA, 0 V Upper signal level 20 mA ... 20.5 mA, 10.5 V EMC EN 61326-2-3, 2014/30/EU - 1) All connections are polarity protected. All outputs are overload and short-circuit protected.
- Mechanics
Wetted parts 316L (Ra ≤ 0,8 µm), PEEK Process connection G ¾ A Housing material 303 Housing design With viewing window made from PMMA (acrylic glass) Max. probe load ≤ 6 Nm
- Ambient data
Ambient operating temperature –20 °C ... +60 °C Ambient temperature, storage –40 °C ... +80 °C Outdoor use Only with weather hood
- Classifications
eCl@ss 5.0 27200513 eCl@ss 5.1.4 27200513 eCl@ss 6.0 27200513 eCl@ss 6.2 27200513 eCl@ss 7.0 27200513 eCl@ss 8.0 27200513 eCl@ss 8.1 27200513 eCl@ss 9.0 27200513 eCl@ss 10.0 27200513 eCl@ss 11.0 27200513 eCl@ss 12.0 27200513 ETIM 5.0 EC001447 ETIM 6.0 EC001447 ETIM 7.0 EC001447 ETIM 8.0 EC001447 UNSPSC 16.0901 41113710
-
-
-