Contact
Feedback

DOSIC®

The compact stainless-steel sensor for flexible flow measurement

  • At a glance
    • Flow measurement for water and oil-based liquids
    • Seal-free stainless-steel 316L sensor with Ra ≤ 0.8
    • Straight, self-draining measuring tube
    • Compact design with short installation lengths
    • Configurable digital outputs
    • Temperature measurement
    • IP 67/69 enclosure rating, CIP/SIP-compatible, IO-Link version 1.1
    Your Benefits
    • Flexible measurement system for all industries and liquids
    • Versatile use for conductive and non-conductive liquids and temperature measurement
    • Short installation lengths and a compact design enable installation in applications with limited space
    • Food-safe thanks to rust-free stainless steel and hygienic design
    • Quick installation without medium calibration
    • User-friendly application thanks to rotatable housing and display
    • Straight measuring tube reduces pressure loss, thus reducing energy costs
    DOSIC®
    The compact stainless-steel sensor for flexible flow measurement

    The non-contact DOSIC® flowmeter detects the flow volume of conductive and non-conductive liquids based on ultrasonic technology. With its measurement channel and stainless-steel housing, the ultrasonic flowmeter is suitable for measuring tasks in hygienic environments. The compact and rugged design offers a wide variety of application possibilities, including in those where space restrictions or aggressive media play a role. Installation is quick and easy, and does not require medium calibration. The seal-free, self-draining measuring tube enhances process reliability. Up to two configurable digital and analog outputs as well as the IO-Link interface ensure the right initial situation. The DOSIC® is EHEDG-certified and FDA-compliant.

    • Technical data overview
      Measurement principleUltrasonic sensor
      MediumConductive and non-conductive liquids
      Output signal

      1 x analog output: 4 mA ... 20 mA, 2 x digital input or output (configurable) 1) 2)

      2 x analog output: 4 mA ... 20 mA, 2 x digital input or output (configurable) 1) 2)

      Nominal width measuring tubeDN 15 / DN 25
      Maximum adjustable measuring range0 l/min ... 250 l/min
      • 1) Digital output configuration: PNP/NPN/push-pull/open collector.
      • 2) Selectable analog output: flow/temperature.
Please select your products
Show all Hide all
Filter by:

16 results:

Result 1 - 16 out of 16

1072035
DOSIC®
Flow sensors
  • Nominal width measuring tube: DN 15
  • Maximum flow: 80 l/min
  • Wetted parts: Stainless steel 1.4404 (Ra ≤ 0,8 µm)
  • Process connection: Clamp (DIN 32676) DN 15
  • Output signal: 1 x analog output: 4 mA ... 20 mA, 2 x digital input or output (configurable)
  • Process temperature: 0 °C ... +95 °C, up to 143°C for 60 minutes for SIP process (temperature measurement only)
  • Process pressure: –0.5 bar ... 16 bar
  • Accuracy of sensor element: ± 1 % (From measured value)
  • Details
  • Compare now
1082020
DOSIC®
Flow sensors
  • Nominal width measuring tube: DN 15
  • Maximum flow: 80 l/min
  • Wetted parts: Stainless steel 1.4404 (Ra ≤ 0,8 µm)
  • Process connection: DIN 11851 DN 15
  • Output signal: 1 x analog output: 4 mA ... 20 mA, 2 x digital input or output (configurable)
  • Process temperature: 0 °C ... +95 °C, up to 143°C for 60 minutes for SIP process (temperature measurement only)
  • Process pressure: –0.5 bar ... 16 bar
  • Accuracy of sensor element: ± 1 % (From measured value)
  • Details
  • Compare now
1082021
DOSIC®
Flow sensors
  • Nominal width measuring tube: DN 15
  • Maximum flow: 80 l/min
  • Wetted parts: Stainless steel 1.4404 (Ra ≤ 0,8 µm)
  • Process connection: G ¾
  • Output signal: 1 x analog output: 4 mA ... 20 mA, 2 x digital input or output (configurable)
  • Process temperature: 0 °C ... +95 °C, up to 143°C for 60 minutes for SIP process (temperature measurement only)
  • Process pressure: –0.5 bar ... 16 bar
  • Accuracy of sensor element: ± 1 % (From measured value)
  • Details
  • Compare now
1082022
DOSIC®
Flow sensors
  • Nominal width measuring tube: DN 15
  • Maximum flow: 80 l/min
  • Wetted parts: Stainless steel 1.4404 (Ra ≤ 0,8 µm)
  • Process connection: ¾ NPT
  • Output signal: 1 x analog output: 4 mA ... 20 mA, 2 x digital input or output (configurable)
  • Process temperature: 0 °C ... +95 °C, up to 143°C for 60 minutes for SIP process (temperature measurement only)
  • Process pressure: –0.5 bar ... 16 bar
  • Accuracy of sensor element: ± 1 % (From measured value)
  • Details
  • Compare now
1082023
DOSIC®
Flow sensors
  • Nominal width measuring tube: DN 15
  • Maximum flow: 80 l/min
  • Wetted parts: Stainless steel 1.4404 (Ra ≤ 0,8 µm)
  • Process connection: Clamp (DIN 32676) DN 15
  • Output signal: 2 x analog output: 4 mA ... 20 mA, 2 x digital input or output (configurable)
  • Process temperature: 0 °C ... +95 °C, up to 143°C for 60 minutes for SIP process (temperature measurement only)
  • Process pressure: –0.5 bar ... 16 bar
  • Accuracy of sensor element: ± 1 % (From measured value)
  • Details
  • Compare now
1082024
DOSIC®
Flow sensors
  • Nominal width measuring tube: DN 15
  • Maximum flow: 80 l/min
  • Wetted parts: Stainless steel 1.4404 (Ra ≤ 0,8 µm)
  • Process connection: G ¾
  • Output signal: 2 x analog output: 4 mA ... 20 mA, 2 x digital input or output (configurable)
  • Process temperature: 0 °C ... +95 °C, up to 143°C for 60 minutes for SIP process (temperature measurement only)
  • Process pressure: –0.5 bar ... 16 bar
  • Accuracy of sensor element: ± 1 % (From measured value)
  • Details
  • Compare now
1082025
DOSIC®
Flow sensors
  • Nominal width measuring tube: DN 15
  • Maximum flow: 80 l/min
  • Wetted parts: Stainless steel 1.4404 (Ra ≤ 0,8 µm)
  • Process connection: DIN 11851 DN 15
  • Output signal: 2 x analog output: 4 mA ... 20 mA, 2 x digital input or output (configurable)
  • Process temperature: 0 °C ... +95 °C, up to 143°C for 60 minutes for SIP process (temperature measurement only)
  • Process pressure: –0.5 bar ... 16 bar
  • Accuracy of sensor element: ± 1 % (From measured value)
  • Details
  • Compare now
1082026
DOSIC®
Flow sensors
  • Nominal width measuring tube: DN 15
  • Maximum flow: 80 l/min
  • Wetted parts: Stainless steel 1.4404 (Ra ≤ 0,8 µm)
  • Process connection: ¾ NPT
  • Output signal: 2 x analog output: 4 mA ... 20 mA, 2 x digital input or output (configurable)
  • Process temperature: 0 °C ... +95 °C, up to 143°C for 60 minutes for SIP process (temperature measurement only)
  • Process pressure: –0.5 bar ... 16 bar
  • Accuracy of sensor element: ± 1 % (From measured value)
  • Details
  • Compare now
1082027
DOSIC®
Flow sensors
  • Nominal width measuring tube: DN 25
  • Maximum flow: 250 l/min
  • Wetted parts: Stainless steel 1.4404 (Ra ≤ 0,8 µm)
  • Process connection: Clamp (DIN 32676) DN 25
  • Output signal: 1 x analog output: 4 mA ... 20 mA, 2 x digital input or output (configurable)
  • Process temperature: 0 °C ... +95 °C, up to 143°C for 60 minutes for SIP process (temperature measurement only)
  • Process pressure: –0.5 bar ... 16 bar
  • Accuracy of sensor element: ± 1 % (From measured value)
  • Details
  • Compare now
1082028
DOSIC®
Flow sensors
  • Nominal width measuring tube: DN 25
  • Maximum flow: 250 l/min
  • Wetted parts: Stainless steel 1.4404 (Ra ≤ 0,8 µm)
  • Process connection: G 1 ¼
  • Output signal: 1 x analog output: 4 mA ... 20 mA, 2 x digital input or output (configurable)
  • Process temperature: 0 °C ... +95 °C, up to 143°C for 60 minutes for SIP process (temperature measurement only)
  • Process pressure: –0.5 bar ... 16 bar
  • Accuracy of sensor element: ± 1 % (From measured value)
  • Details
  • Compare now
1082029
DOSIC®
Flow sensors
  • Nominal width measuring tube: DN 25
  • Maximum flow: 250 l/min
  • Wetted parts: Stainless steel 1.4404 (Ra ≤ 0,8 µm)
  • Process connection: DIN 11851 DN 25
  • Output signal: 1 x analog output: 4 mA ... 20 mA, 2 x digital input or output (configurable)
  • Process temperature: 0 °C ... +95 °C, up to 143°C for 60 minutes for SIP process (temperature measurement only)
  • Process pressure: –0.5 bar ... 16 bar
  • Accuracy of sensor element: ± 1 % (From measured value)
  • Details
  • Compare now
1082030
DOSIC®
Flow sensors
  • Nominal width measuring tube: DN 25
  • Maximum flow: 250 l/min
  • Wetted parts: Stainless steel 1.4404 (Ra ≤ 0,8 µm)
  • Process connection: 1 ¼ NPT
  • Output signal: 1 x analog output: 4 mA ... 20 mA, 2 x digital input or output (configurable)
  • Process temperature: 0 °C ... +95 °C, up to 143°C for 60 minutes for SIP process (temperature measurement only)
  • Process pressure: –0.5 bar ... 16 bar
  • Accuracy of sensor element: ± 1 % (From measured value)
  • Details
  • Compare now
1082031
DOSIC®
Flow sensors
  • Nominal width measuring tube: DN 25
  • Maximum flow: 250 l/min
  • Wetted parts: Stainless steel 1.4404 (Ra ≤ 0,8 µm)
  • Process connection: Clamp (DIN 32676) DN 25
  • Output signal: 2 x analog output: 4 mA ... 20 mA, 2 x digital input or output (configurable)
  • Process temperature: 0 °C ... +95 °C, up to 143°C for 60 minutes for SIP process (temperature measurement only)
  • Process pressure: –0.5 bar ... 16 bar
  • Accuracy of sensor element: ± 1 % (From measured value)
  • Details
  • Compare now
1082033
DOSIC®
Flow sensors
  • Nominal width measuring tube: DN 25
  • Maximum flow: 250 l/min
  • Wetted parts: Stainless steel 1.4404 (Ra ≤ 0,8 µm)
  • Process connection: G 1 ¼
  • Output signal: 2 x analog output: 4 mA ... 20 mA, 2 x digital input or output (configurable)
  • Process temperature: 0 °C ... +95 °C, up to 143°C for 60 minutes for SIP process (temperature measurement only)
  • Process pressure: –0.5 bar ... 16 bar
  • Accuracy of sensor element: ± 1 % (From measured value)
  • Details
  • Compare now
1082034
DOSIC®
Flow sensors
  • Nominal width measuring tube: DN 25
  • Maximum flow: 250 l/min
  • Wetted parts: Stainless steel 1.4404 (Ra ≤ 0,8 µm)
  • Process connection: DIN 11851 DN 25
  • Output signal: 2 x analog output: 4 mA ... 20 mA, 2 x digital input or output (configurable)
  • Process temperature: 0 °C ... +95 °C, up to 143°C for 60 minutes for SIP process (temperature measurement only)
  • Process pressure: –0.5 bar ... 16 bar
  • Accuracy of sensor element: ± 1 % (From measured value)
  • Details
  • Compare now
1082035
DOSIC®
Flow sensors
  • Nominal width measuring tube: DN 25
  • Maximum flow: 250 l/min
  • Wetted parts: Stainless steel 1.4404 (Ra ≤ 0,8 µm)
  • Process connection: 1 ¼ NPT
  • Output signal: 2 x analog output: 4 mA ... 20 mA, 2 x digital input or output (configurable)
  • Process temperature: 0 °C ... +95 °C, up to 143°C for 60 minutes for SIP process (temperature measurement only)
  • Process pressure: –0.5 bar ... 16 bar
  • Accuracy of sensor element: ± 1 % (From measured value)
  • Details
  • Compare now

Result 1 - 16 out of 16

TOP