Contact
Feedback

CEMS solutions

Tailored for measuring emissions

SICK's CEMS solutions are analyzer solutions that have been specifically designed for measuring emissions at power plants, industrial facilities, or on ships. CEMS solutions can be used to measure pollutants and reference quantities and to perform data processing on the results in accordance with the relevant national or international legislation.

Filter by:

16 results:

Result 1 - 16 out of 16

View: View Gallery View List
Product family MARSIC
Safely on the right course
  • Rugged design and high level of measurement accuracy
  • Up to four measurement points with one analyzer
  • DNV GL type approval in accordance with MARPOL Annex VI, NOx Technical Code 2008, MEPC.184(59) and MEPC.198(62)
  • Measuring ranges adapted to low and high concentrations of SO2 and NOx
  • Up to 9 measuring components simultaneously: SO2, CO2, CO, NO, NO2, NH3, CH4, H2O, and O2
Product family MEAC300
Clear and cost-efficient emissions data management
  • Bus-capable data acquisition from measuring devices and plants
  • Evaluation conforming to the Industrial Emissions Directive, EN 14181 QAL2, and optionally QAL3 (CUSUM)
  • Secure storage with automated backup
  • Ergonomic display for constant monitoring of evaluation rules and device statuses
  • Fast data transmission to the plant control in a 5 s cycle
Product family MEAC
Tested and reliable emission data management
  • Evaluations according to 1, 2, 13, 17, 27, 30, 31 BImSchV and TA Luft
  • Analog and digital data collection saved at 5 s/1 min intervals with auto-backup
  • Distributed visualization, operation in the network and automatic e-mail alarms
  • Flexible data presentation also in process images
  • Analog and digital data to the customer system at 5 s/1 min intervals
  • Recording of QAL3 cycles
Product family MCS100FT
Everything under control with advanced, proven technology
  • Lowest approved HF measuring range: 0 ... 3 mg/m³
  • Automatic spectrum adjustment via AutoVAL for reliable measuring values
  • Operation via touchscreen
  • Sample gas transport by an ejector without moving parts
  • Approved according to EN 15267
  • Remote control and diagnosis via software SOPAS ET
  • Automatic adjustment of analyzer
  • Automatic backflushing and filter cleaning of sampling unit
Product family MCS100E HW
Emission and raw gas monitoring with hot measuring technology
  • Extractive measurement of up to 8 IR-active gas components
  • Additional oxygen and total hydrocarbon analyzer as option
  • Gas lines heated throughout
  • Sample gas infeed on gas sampling probe or analyzer
  • Back-purging of gas sampling probe for filter cleaning
  • Rapid measured gas exchange to minimize adsorption and desorption processes
  • Automated sample point switching
Product family MCS100E CD
Emission monitoring of very small measuring ranges
  • Extractive measurement of up to 8 IR-active gas components
  • Additional oxygen sensor as an option
  • Integrated gas cooler
  • Sample gas infeed on gas sampling probe or analyzer
  • Back-purging of gas sampling probe for filter cleaning
  • Rapid measured gas exchange to minimize adsorption and desorption processes
  • Automated sample point switching
Product family MCS100E PD
Emission monitoring of very small measuring ranges – including for HCI
  • Extractive measurement of up to 8 IR-active gas components
  • Additional oxygen sensor as an option
  • Integrated permeation dryer
  • Sample gas infeed on gas sampling probe or analyzer
  • Back-purging of gas sampling probe for filter cleaning
  • Rapid measured gas exchange to minimize adsorption and desorption processes
  • Automated sample point switching
Product family GHG-Control
Measuring rather than calculating greenhouse gases
  • In-situ solution for measuring CO2 and N2O emissions
  • Direct measurement even with changing fuels and mixed fuels
  • Measurement without converting from the dry to damp status
  • Transfer of the greenhouse gas loads directly to the control unit
Product family MCS100E HW-C
A raw gas and emissions monitoring system solution
  • Measures up to 8 IR-active gas compounds
  • Gas paths completely heated to prevent corrosion and measurement error produced by condensation
  • Optional zirconium dioxide sensor for O2 measurement
  • Supports calibration of the full system or direct calibration of the analyzer
  • Multi-stage filtration allows safe sampling
  • Automatic zero and span point calibration, and internal calibration filter allows for calibration without test gas
  • Regular back-purging
  • Incorporates temperature and flow control and automatic sampling cut-off if malfunction occurs
  • Automatic purging protects the instrument in case of malfunction
Product family SMC9021F
Online monitoring of volatile organic compound (VOC) emissions
  • Touch-key operation with multi-level password protection
  • Built-in ejector to reduce component wear
  • A pressure module controls airflow into the analysis unit
  • A catalytic device may be internally fitted to purify the gas entering the analyzer
  • Sample gas inlet protected by filter
  • Multiple gas sampling
  • Long maintenance interval of up to 3 months
Product family MCS100FT-C
The all-purpose champion of meeting environmental emissions monitoring needs
  • Touch-screen operation with multiple levels of password protection
  • Ethernet interface for remote diagnostics and operation
  • Gas paths completely heated to prevent corrosion and measurement error produced by condensation
  • Built-in ejector reduces component wear
  • Optional zirconium dioxide sensor for O2 measurement
  • Utilizes Fourier infrared technology for rapid measurement of multiple gas components
  • Supports calibration of the full system or direct calibration of the analyzer
  • Multi-stage filtration allows safe sampling
  • Automatic zeroing, span calibration, and regular back-purging
  • Includes temperature and flow control and automatic sampling cut-off if malfunction occurs
  • Automatic purging protects the instrument in case of malfunction
  • The interferometer can be unaffected by vibrations
Product family SMC9021
A continuous emission monitoring system
  • The heated sampling probe prevents the flue gas from cooling during the sampling process
  • The sampling probe has back-purge functionality for longer maintenance intervals
  • Supports PLC controlled automatic back-purge, drainage, and calibration to ensure long-term up-time
  • Alarm parameters may be set for temperature, flow rate, and humidity for easy operation of the monitoring system
  • Multiple configurations available (S700 series)
  • Additional measurement capabilities available (oxygen content, dust content, flow rate measurement, etc.)
Product family SMC209C
SMC209 C, the extractive flue gas humidity analyzer
  • Utilizes capacitance measurement principle
  • Auxiliary electrical heating can heat the measuring system
Product family SMC222
A Pitot tube flow velocity measuring device
  • Provides users with a standard 4 ... 20 mA output proportional to the flow rate
Product family SMC900
Data monitoring and control system for continuous emissions monitoring systems
  • The system has passed the inspection of the Instrument Testing Center of China's Ministry of Environmental Protection
  • Supports multiple log-in privileges to maintain confidentiality
  • Can generate reports according to user-specified formats
Product family Combiprobe CP100
Combined measurement of dust, volume flow, pressure, and temperature
  • No need for mechanical adjustment
  • Self-testing with the automatic control cycle
  • Simple configuration and operation with easy-to-use software
  • For gas temperatures up to 200 °C
  • For funnels with an internal diameter of 0.7 m and above

Result 1 - 16 out of 16