Measured values | Scattered light intensity, dust concentration (after gravimetric comparison measurement) |
Performance-tested measurands | Dust concentration |
Measurement principles | Scattered light forward |
Spectral range | | | 640 nm ... 660 nm Laser, protection class 2, power < 1 mW |
|
Measuring ranges | | Dust concentration | 0 ... 5 mg/m³ / 0 ... 500 mg/m³ | | Measuring ranges freely selectable | | Higher measuring ranges on request |
|
Certified measuring ranges | | Dust concentration | 0 ... 7.5 mg/m³ / 0 ... 10 mg/m³ / 0 ... 15 mg/m³ / 0 ... 50 mg/m³ / 0 ... 100 mg/m³ / 0 ... 500 mg/m³ |
|
Response time (t90) | | | 0.1 s ... 600 s Freely adjustable |
|
Accuracy | | | ± 2 % Of measuring range full scale |
|
Process temperature | | PVDF gas removal probe | ≤ +120 °C | Hastelloy gas removal probe | ≤ +220 °C Versions for higher temperatures on request |
|
Process pressure | | With SLV7 2BH1100 purge air unit | –20 hPa ... 20 hPa Other pressure ranges on request |
|
Process gas velocity | | | 5 m/s ... 30 m/s |
|
Process gas humidity | | | Max. 40 g/m³ liquid water without water vapour |
|
Ambient temperature | | | –20 °C ... +50 °C | Intake temperatures for purge air | –20 °C ... +45 °C |
|
Conformities | Approved for plants requiring approval 2001/80/EC (13. BImSchV) 2000/76/EC (17. BImSchV) 27. BImSchV TA-Luft (Prevention of Air Pollution) EN 15267 EN 14181 U.S. EPA PS-11 compliant When options are used, agreement with local authorities may be required |
Electrical safety | CE |
Enclosure rating | | Measuring and control unit | IP54 | Electronics enclosure | IP65 |
|
Analog outputs | 3 outputs: 0/2/4 ... 20 mA, + 750 Ω Electrically isolated |
Analog inputs | 6 inputs: 0 ... 20 mA Not electrically isolated |
Digital outputs | 5 relay outputs (change-over contacts), potential-free: 48 V, 1 A |
Digital inputs | 8 inputs |
Modbus | ✔ , ✔ | Type of fieldbus integration | TCP (via optional interface module, only one module possible per MCU) | | RTU RS-485 (via optional interface module, only one module possible per MCU) |
|
PROFIBUS DP | ✔ | Type of fieldbus integration | Via optional interface module (only one module possible per MCU) |
|
Ethernet | ✔ | Type of fieldbus integration | Via optional interface module (only one module possible per MCU) | Function | Connection to SOPAS ET software or OPC server |
|
Serial | ✔ | Type of fieldbus integration | RS-232 | Function | Proprietary service interface |
|
Indication | | | LC display and status LEDs on control and remote unit |
|
Input | Functional keys |
Operation | Menu-driven operation via control unit or software SOPAS ET |
Dimensions (W x H x D) | | FWE200DH measuring and control unit | 813 mm x 722 mm x 286 mm (for details see dimensional drawings) |
|
Weight | | FWE200DH measuring and control unit | 65 kg | Sampling probe | ≤ 15 kg |
|
Material in contact with media | PVDF, Hastelloy |
Power supply | | Voltage | 115 V AC | | 230 V AC | Frequency | 50 Hz / 60 Hz | Power consumption | FWE200DH measuring and control unit: 800 VA ... 1,700 VA | | Air heater: ≤ 1,000 VA | | Sample gas line, heated: ≤ 300 VA |
|
Test functions | Automated self-test (zero point, contamination, drift) Contamination limit values: Warning at 30%; fault at 40% Manual linearity test with reference filter |
Options | FWE200DH mounting rack Air backwash Water backwash Sample gas line, heated Air heater |