Flexi Loop
Cost-saving and safe series connection with diagnostic function
Please select your products
11 results:
- Flexi Loop component: Node for safety sensors (OSSD)
- Use of Flexi Loop node: For safety sensor with dual-channel OSSD outputs, With standard input, With standard output
- Connection type safety device: Female connector M12, 8-pin
- Flexi Loop component: Node for safety sensors (OSSD)
- Use of Flexi Loop node: For safety sensor with dual-channel OSSD outputs, With standard input
- Connection type safety device: Female connector M12, 5-pin
- Flexi Loop component: Node for safety switch (EMSS)
- Use of Flexi Loop node: For dual-channel equivalent electro-mechanical safety switch (EMSS)
- Connection type safety device: Female connector M12, 5-pin
- Flexi Loop component: Node for safety switch (EMSS)
- Use of Flexi Loop node: For dual-channel equivalent electro-mechanical safety switch (EMSS), With standard input, With standard output
- Connection type safety device: Female connector M12, 8-pin
- Flexi Loop component: Module for energy supply
- Description: The power supply module is used to connect a power supply with 24 V DC, for the electrical isolation and for overcurrent shutdown.
- Flexi Loop component: Y-adapter
- Description: The Flexi Loop Y-adapter (EMMS) splits the 8-pin connection of the FLN-EMSS1100108 in two 5-pin connections: One for dual-channel equivalent electro-mechanical safety switches and one for non-safe I/O signals.
- Flexi Loop component: Y-adapter
- Description: The Flexi Loop Y-adapter (OSSD) splits the 8-pin connection of the FLN-OSSD1100108 in two 5-pin connections: One for safety sensors with dual-channel OSSD outputs and one for non-safe I/O signals.
- Flexi Loop component: Module to terminate series connection
- Description: The terminator is used to terminate the safe series connection at the last Flexi Loop node.
- Flexi Loop component: Module for connection to Flexi Classic
- Description: Flaxi Loop master node to connect a Flexi Loop cascade to Flexi Classic. System diagnostics during operation and during commisioning without busmaster.
- Flexi Loop component: Module for connection to Flexi Classic
- Description: Flaxi Loop master node to connect a Flexi Loop cascade to Flexi Classic. System diagnostics during operation and during commisioning without busmaster.
- Additional interfaces: IO-Link
- Flexi Loop component: Module for field diagnostics
- Description: The diagnostics module is used as a commissioning aid and to display the Flexi Loop states during operation.