Small photoelectric sensors
W12-2 Laser
WS/WE12L-2P410
1018256
Items included:
BEF-KH-W12 (2)
-
Technical details
-
Downloads
-
Accessories
-
Videos
-
Items supplied
-
Service and Support
-
Customs data
-
- Features
Sensor/ detection principle Through-beam photoelectric sensor Dimensions (W x H x D) 15 mm x 49 mm x 41.5 mm Housing design (light emission) Rectangular Sensing range max. 0 m ... 10 m Type of light Visible red light Light source Laser 1) 2) Light spot size (distance) Ø 1 mm (1 m) Wave length 650 nm Laser class 2 (EN 60825-1:2014, IEC 60825-1:2007) 3) Adjustment Potentiometer Special applications Detecting small objects, Detection of objects moving at high speeds - 1) Average service life: 50,000 h at TU = +25 °C.
- 2) Parallel light beam.
- 3) Pulse length 4 µs, max. pulse power < 5,0 mW.
- Mechanics/electronics
Supply voltage 10 V DC ... 30 V DC 1) Ripple < 5 Vpp 2) Power consumption, sender ≤ 45 mA 3) Power consumption, receiver ≤ 15 mA 3) Switching output PNP Switching mode selector Selectable via L/D control cable Signal voltage PNP HIGH/LOW Uv - < 2.9 V, Uv V / 0 V <= 1.5 V Signal voltage NPN HIGH/LOW Uv - < 2.9 V, Uv V / 0 V <= 1.5 V Output current Imax. ≤ 100 mA Response time ≤ 200 µs 4) Switching frequency 2,500 Hz 5) Connection type Male connector M12, 4-pin Circuit protection A 6)
C 7)
D 8)
Protection class III Weight 260 g Housing material Metal Optics material Plastic, PMMA Enclosure rating IP67
IP69K
Items supplied 2 x clamps BEF-KH-W12, incl. screws Ambient operating temperature –10 °C ... +50 °C Ambient temperature, storage –25 °C ... +75 °C UL File No. NRKH.E181493 & NRKH7.E181493 Part number of individual components 2021726 WE12L-2P430 2022025 WS12L-2D410 - 1) Limit values when operated in short-circuit protected network: max. 8 A.
- 2) May not exceed or fall below Uv tolerances.
- 3) Without load.
- 4) Signal transit time with resistive load.
- 5) With light/dark ratio 1:1.
- 6) A = VS connections reverse-polarity protected.
- 7) C = interference suppression.
- 8) D = outputs overcurrent and short-circuit protected.
- Safety-related parameters
MTTFD 283 years DCavg 0%
- Classifications
ECl@ss 5.0 27270901 ECl@ss 5.1.4 27270901 ECl@ss 6.0 27270901 ECl@ss 6.2 27270901 ECl@ss 7.0 27270901 ECl@ss 8.0 27270901 ECl@ss 8.1 27270901 ECl@ss 9.0 27270901 ECl@ss 10.0 27270901 ECl@ss 11.0 27270901 ETIM 5.0 EC002716 ETIM 6.0 EC002716 ETIM 7.0 EC002716 UNSPSC 16.0901 39121528
-
-
-
-