Scattered light dust measuring devices
DUSTHUNTER SB30

Your Benefits

  • Easy installation, commissioning, and operation
  • Tried-and-tested measurement, not dependent on gas velocity, humidity, or particle load
  • Cost-effective thanks to easy mounting on just one side; no alignment necessary
  • Very low-maintenance thanks to self-monitoring
  • Demand-controlled maintenance notifications

The exact device specifications and performance data of the product may deviate from the information provided here, and depend on the application in which the product is being used and the relevant customer specifications.

Overview

The DUSTHUNTER SB30 is a measuring device, designed to detect very low to moderate dust concentrations, such as in hot or volatile gases. Measurement is based on the tried-and-tested measurement principle of backward light scattering. Installation is easy and is only carried out on one side of the channel. Two different penetration depths are possible for adapting the measuring device to various channel diameters.

At a glance
  • For low to medium dust content
  • Easy one-sided installation
  • Automatic check of zero and reference point
  • For medium to large duct diameters

Accessories

Spare parts

Applications

Service & Support

Technical overview

 
  • DUSTHUNTER SB30 system

    DUSTHUNTER SB30 system

    Measured valuesScattered light intensity, dust concentration (after gravimetric comparison measurement)
    Measurement principlesScattered light backward
    Spectral range
    640 nm ... 660 nm
    Laser, protection class 2, power < 1 mW
    Measuring ranges
    Scattered light intensity0 ... 7.5 SI / 0 ... 3,000 SI
    Two freely configurable measuring ranges via SOPAS ET
    Nine preset measuring ranges (0 ... 7.5/15/45/75/150/225/375/1,000/3,000 SI)
    Response time (t90)
    1 s ... 600 s
    Freely adjustable via SOPAS ET software
    Accuracy
    ± 2 %
    Of measuring range full scale
    Repeatability
    Zero point0.1 %
    Conformities

    TUEV type-examination

    China's EPA compliant

    Electrical safetyCE
    Test functions

    Automatic self-test (linearity, drift, aging)

    Manual linearity test with reference filter

    Options

    MCU control unit

    External purge air unit

  • DHSB-T30 sender/receiver unit

    DHSB-T30 sender/receiver unit

    DescriptionAnalyzer unit of the measuring system
    Process temperature
    –40 °C ... +600 °C
    Process pressure
    With MCU-P control unit–50 hPa ... 2 hPa
    With external purge air unit–50 hPa ... 30 hPa
    Duct diameter
    ≥ 0.5 m
    Ambient temperature
    –40 °C ... +60 °C
    Electrical safetyCE
    Enclosure rating
    IP66
    Analog outputs1 output:
    4 ... 20 mA, 750 Ω
    Electrically isolated
    Digital outputs3 NO:
    48 V, 1 A
    Potential-free; for status signals
    Digital inputs4 potential-free contacts:
    For external maintenance switch, automatic self test, linearity measurement, calibration curve switching, or filter monitoring
    Modbus
    Type of fieldbus integrationRTU RS-485
    Serial
    Type of fieldbus integrationRS-485
    FunctionFor operation via a service adapter and SOPAS ET or via the MCU option
    Dimensions (W x H x D)
    265 mm x 265 mm x 295 mm (for details see dimensional drawings)
    Weight
    7 kg
    Power supply
    Voltage24 V DC
    VoltageSupply via MCU control unit or an external power supply
    Power consumption≤ 4 W
  • MCU-N control unit

    MCU-N control unit

    DescriptionUnit to control the system components and to evaluate and output the data provided by them
    Ambient temperature
    –40 °C ... +60 °C
    Electrical safetyCE
    Enclosure rating
    IP66
    Analog outputs1 output:
    0/2/4 ... 20 mA, 750 Ω
    Electrically isolated; two additional outputs if using I/O modules (option)
    Analog inputs2 inputs:
    0 ... 20 mA
    Not electrically isolated; two additional inputs if using I/O modules (option)
    Digital outputs5 relay contacts:
    48 V, 1 A
    Potential-free; for status signals
    Digital inputs4 potential-free contacts
    Modbus✔ , ✔
    Type of fieldbus integrationTCP (via optional interface module, only one module possible per MCU)
    RS-485 (via optional interface module, only one module possible per MCU)
    PROFIBUS DP
    Type of fieldbus integrationVia optional interface module (only one module possible per MCU)
    Ethernet
    Type of fieldbus integrationVia optional interface module (only one module possible per MCU)
    FunctionConnection to SOPAS ET software or OPC server
    Indication
    LC display (option)
    Status LEDs: “Power,” “Failure,” and “Maintenance request”
    OperationVia LC-display (option) or software SOPAS ET
    Dimensions (W x H x D)
    210 mm x 340 mm x 120 mm (for details see dimensional drawings)
    Weight
    ≤ 3.7 kg
    Power supply
    Voltage90 V AC ... 250 V AC
    VoltageVersion with 24 V DC available as an option
    Frequency47 ... 63 Hz
    Power consumption≤ 15 VA
    Options

    Interface module(s)

    I/O module(s)

  • MCU-P control unit

    MCU-P control unit

    DescriptionUnit to control the system components and to evaluate and output the data provided by them. With integrated purge air unit.
    Gas flow rate
    ≤ 20 m³/h
    Ambient temperature
    –40 °C ... +45 °C
    Intake temperatures for purge air
    Electrical safetyCE
    Enclosure rating
    IP66
    Analog outputs1 output:
    0/2/4 ... 20 mA, 750 Ω
    Electrically isolated; two additional outputs if using I/O modules (option)
    Analog inputs2 inputs:
    0 ... 20 mA
    Not electrically isolated; two additional inputs if using I/O modules (option)
    Digital outputs5 relay contacts:
    48 V, 1 A
    Potential-free; for status signals
    Digital inputs4 potential-free contacts
    Modbus✔ , ✔
    Type of fieldbus integrationTCP (via optional interface module, only one module possible per MCU)
    RS-485 (via optional interface module, only one module possible per MCU)
    PROFIBUS DP
    Type of fieldbus integrationVia optional interface module (only one module possible per MCU)
    Ethernet
    Type of fieldbus integrationVia optional interface module (only one module possible per MCU)
    FunctionConnection to SOPAS ET software or OPC server
    Indication
    LC display (option)
    Status LEDs: “Power,” “Failure,” and “Maintenance request”
    OperationVia LC-display (option) or software SOPAS ET
    Dimensions (W x H x D)
    300 mm x 455 mm x 220 mm (for details see dimensional drawings)
    Weight
    ≤ 13.5 kg
    Power supply
    Voltage90 V AC ... 250 V AC
    VoltageVersion with 24 V DC available as an option
    Frequency47 ... 63 Hz
    Power consumption≤ 70 VA
    Options

    Interface module(s)

    I/O module(s)

  • SLV4-2 purge air unit, 2BH1300, 3-ph

    SLV4-2 purge air unit, 2BH1300, 3-ph

    DescriptionUnit to provide dust-free air for flushing of optical surfaces
    Gas flow rate
    38 m³/h ... 63 m³/h
    At 30 hPa counter pressure, depending on low pressure inside the filter
    Ambient temperature
    –40 °C ... +55 °C
    Electrical safetyCE
    Enclosure rating
    IP54
    Dimensions (W x H x D)
    550 mm x 550 mm x 257 mm (for details see dimensional drawings)
    Weight
    18 kg
    Power supply
    Three-phase currentΔ: 200 ... 240 V AC, 50 Hz, 2,6 A, 400 VA
    Y: 345 ... 415 V AC, 50 Hz, 1,5 A, 400 VA
    Δ: 200 ... 275 V AC, 60 Hz, 2,6 A, 500 VA
    Y: 380 ... 480 V AC, 60 Hz, 1,5 A, 500 VA
    Δ: 270 ... 330 V AC, 50 Hz, 2,0 A, 400 VA
    Y: 465 ... 570 V AC, 50 Hz, 1,16 A, 400 VA
    Δ: 290 ... 360 V AC, 60 Hz, 2,1 A, 500 VA
    Y: 500 ... 600 V AC, 60 Hz, 1,26 A, 500 VA
    Δ: 230 V AC, 50 Hz, 2,7 A, 370 VA
    Δ: 115 V AC, 60 Hz, 3,0 A, 450 VA
    Δ: 220 ... 270 V AC, 50 Hz, 2,5 A, 400 VA
    Y: 380 ... 465 V AC, 50 Hz, 1,45 A, 400 VA
    Δ: 240 ... 290 V AC, 60 Hz, 2,6 A, 500 VA
    Y: 415 ... 500 V AC, 60 Hz, 1,55 A, 500 VA
    Auxiliary gas connections
    Purge air40 mm
    Test functionsPressure switch (switching point –35 hPa)
    Integrated components2-step air filter, type Europiclon, dust capacity 200 g
All technical data can be found accompanying the individual product