- Home
- Product portfolio
- Automation light grids
- Measuring automation light grids
- MLG-2 WebChecker
- MLG05W-0G00G12501
Measuring automation light grids
MLG-2 WebChecker
-
Technical details
-
Downloads
-
Accessories
-
Videos
-
Service and Support
-
Customs data
-
- Features
Device version Web guiding Sensor principle Sender/receiver Minimum object length 4 mm 1) Beam separation 5 mm Resolution 0.1 mm Cycle time 32 µs per beam Repeatability 6 µm 2) Accuracy ± 0.3 mm 3) Type of synchronization Cable Number of beams 480 Total measuring field width 2,395 mm Measuring field width detailed Measuring field width (connection side) 2,395 mm Blind zone (medium range) 0 mm Measuring field width (head side) 0 mm Software features (default) Q1/C Alarm, general Q2 Standard teach-in Q3 Edge position 1 QA Edge position 1, rising Application Standard mode Included with delivery 1 × sender
1 × receiver
4/6 x QuickFix brackets (6 x QuickFix brackets for monitoring heights above 2 m)
1 × Quick Start Guide
- 1) See graphic: product definition.
- 2) 1 sigma, 0% object transmission (sensor internal value).
- 3) For opaque objects and exact alignment of sender/receiver.
- Mechanics/electronics
Light source LED, Infrared light Wave length 850 nm Supply voltage Vs DC 19.2 V ... 28.8 V 1) Power consumption sender 79 mA 2) Power consumption receiver 216 mA 2) Ripple < 5 Vpp Output current Imax. 100 mA Output load, capacitive 100 nF Output load, Inductive 1 H Initialization time < 1 s Switching output Push-pull: PNP/NPN Dimensions (W x H x D) 34 mm x 2,479.4 mm x 30.6 mm Connection type Male connector M12, 5-pin, 0.22 m
Male connector M12, 8-pin, 0.27 m
M12 female connector, 4-pin, D-coded, 0.19 m
Housing material Aluminum Indication LED Enclosure rating IP65, IP67
3)Circuit protection UV connections, reverse polarity protected
Output Q short-circuit protected
Interference pulse suppression
Protection class III Weight 5.059 kg Front screen PMMA Option None UL File No. NRKH.E181493 - 1) Without load.
- 2) , Without load with 24 V.
- 3) Operating in outdoor condition only with a external protection housing.
- Performance
Maximum range 3.5 m 1) Minimum range ≥ 0.2 m Operating range 2.5 m Response time 95.8 ms 2) - 1) No reserve for environmental issue and deterioration of the diode.
- 2) With resistive load.
- Communication interface
IO-Link ✔ , IO-Link V1.1 Data transmission rate 230,4 kbit/s (COM3) Maximum cable length 20 m Cycle time 14 ms VendorID 26 DeviceID HEX 80022F DeviceID DEC 8389167 Process data length 32 Byte (TYPE_2_V) 1) Analog ✔ , Current Inputs/outputs 1 x analog + 3 x Q (IO-Link) Analog output QA1 Number 1 Type Current output Current 4 mA ... 20 mA Digital output Q1 ... Q3 Number 3 Digital input Q2, Q3 Number 2 - 1) With an IO-Link master with V1.0, fall back to interleaved mode (consisting of TYPE_1_1 (ProcessData) and TYPE_1_2 (On-request Data)).
- Ambient data
Shock resistance Continuous shocks 10 g, 16 ms, 1000 shocks
Single shocks 15 g, 11 ms 3 per axle
Vibration resistance Sinusoidal oscillation 10-150 Hz 5 g Ambient light immunity 100,000 lx Ambient operating temperature –30 °C ... +55 °C Ambient temperature, storage –40 °C ... +70 °C
- Smart Task
Smart Task name Base logics
- Classifications
ECl@ss 5.0 27270910 ECl@ss 5.1.4 27270910 ECl@ss 6.0 27270910 ECl@ss 6.2 27270910 ECl@ss 7.0 27270910 ECl@ss 8.0 27270910 ECl@ss 8.1 27270910 ECl@ss 9.0 27270910 ECl@ss 10.0 27270910 ECl@ss 11.0 27270910 ECl@ss 12.0 27270910 ETIM 5.0 EC002549 ETIM 6.0 EC002549 ETIM 7.0 EC002549 ETIM 8.0 EC002549 UNSPSC 16.0901 39121528
-
-
-