- Features
Device version Web guiding Sensor principle Sender/receiver Minimum object length 4 mm 1) Beam separation 5 mm Resolution 0.1 mm Cycle time 32 µs per beam Repeatability 6 µm 2) Accuracy ± 0.3 mm 3) Type of synchronization Cable Number of beams 300 Total measuring field width 1,645 mm Measuring field width detailed Measuring field width (connection side) 745 mm Blind zone (medium range) 155 mm Measuring field width (head side) 745 mm Software features (default) Q1 Alarm, general Application Standard mode Included with delivery 1 × sender (in IP69K protective pipes)
1 × receiver (in IP69K protective pipes)
1 x Fieldbus module
1 x IP69K mounting instructions
1 × Quick Start Guide
- 1) See graphic: product definition.
- 2) 1 sigma, 0% object transmission (sensor internal value).
- 3) For opaque objects and exact alignment of sender/receiver.
- Mechanics/electronics
Light source LED, Infrared light Wave length 850 nm Supply voltage Vs DC 19.2 V ... 28.8 V 1) Power consumption sender 70 mA 2) Power consumption receiver 180 mA 2) Fieldbus module current consumption 115 mA Ripple < 5 Vpp Output current Imax. 100 mA Output load, capacitive 100 nF Output load, Inductive 1 H Initialization time < 1 s Switching output Push-pull: PNP/NPN Dimensions (W x H x D) 50 mm x 1,880.1 mm x 50 mm Connection type Male connector M12, 5-pin, 1.4 m
Connector M12, 12-pin, 1.4 m
Housing material Aluminum (light grid)
PMMA Plexiglas XT Food Contact DoC (protective pipe)
Polypropylene, stainless steel 1.4404 (cable)
VA 1.4305 (pressure compensation element)
Stainless steel 1.4404 (end caps)
Stainless steel V4A 1.4404 DIN EN 1672-2 (cable gland)
Indication LED Enclosure rating IP69K
3)Circuit protection UV connections, reverse polarity protected
Output Q short-circuit protected
Interference pulse suppression
Protection class III Weight 3.559 kg Option Protective housing IP69K UL File No. NRKH.E181493 - 1) Without load.
- 2) , Without load with 24 V.
- 3) Operating in outdoor condition only with a external protection housing.
- Performance
Maximum range 3.5 m 1) Minimum range ≥ 0.2 m Operating range 2.5 m Response time 60.3 ms 2) - 1) No reserve for environmental issue and deterioration of the diode.
- 2) With resistive load.
- Communication interface
PROFINET ✔ Digital output Q1 Number 1
- Ambient data
Shock resistance Continuous shocks 10 g, 16 ms, 1000 shocks
Single shocks 15 g, 11 ms 3 per axle
Vibration resistance Sinusoidal oscillation 10-150 Hz 5 g Ambient light immunity 100,000 lx Ambient operating temperature –20 °C ... +55 °C Ambient temperature, storage –40 °C ... +70 °C
- Classifications
eCl@ss 5.0 27270910 eCl@ss 5.1.4 27270910 eCl@ss 6.0 27270910 eCl@ss 6.2 27270910 eCl@ss 7.0 27270910 eCl@ss 8.0 27270910 eCl@ss 8.1 27270910 eCl@ss 9.0 27270910 eCl@ss 10.0 27270910 eCl@ss 11.0 27270910 eCl@ss 12.0 27270910 ETIM 5.0 EC002549 ETIM 6.0 EC002549 ETIM 7.0 EC002549 ETIM 8.0 EC002549 UNSPSC 16.0901 39121528
-
-
-