Scattered light dust measuring devices
Combiprobe CP100
Combined measurement of dust, volume flow, pressure, and temperature
Your Benefits
- Easy to install complete solution for detecting dust emission and the emission-related benchmarks of volume flow, pressure and temperature
- Low operating costs due to the measuring devices' long maintenance intervals
- Durable and reliable components
- Scattered light dust measuring device and volume flow measuring device that have been performance-tested according to EN 15267
The exact device specifications and performance data of the product may deviate from the information provided here, and depend on the application in which the product is being used and the relevant customer specifications.
Overview
Combined measurement of dust, volume flow, pressure, and temperature
The Combiprobe CP100 is the combination of a DUSTHUNTER SP100 scattered light dust measuring device and a FLOWSIC100 PR volume flow measuring device on a flange plate. The combined probe also features a pressure transmitter and a resistance thermometer. The Combiprobe CP100 only requires a single mounting opening in the funnel in order to measure the dust concentration, volume flow, pressure and temperature. This means that there is considerably less outlay on installation than if the individual components were to be installed separately.
At a glance
- No need for mechanical adjustment
- Self-testing with the automatic control cycle
- Simple configuration and operation with easy-to-use software
- For gas temperatures up to 200 °C
- For funnels with an internal diameter of 0.7 m and above
Combiprobe CP100 system
Combiprobe CP100 system
Measured values | Dust concentration (after gravimetric comparison measurement), gas velocity, gas pressure, gas temperature |
Measuring ranges | | Dust concentration | 0 ... 5 mg/m³ / 0 ... 200 mg/m³ | Gas velocity | 0 ... ± 40 m/s / 0 | Absolute gas pressure | 800 ... 1,200 hPa | Gas temperature | –50 ... +400 °C |
|
Response time (t90) | | DUSTHUNTER SP100 | 1 s ... 600 s Freely adjustable | FLOWSIC100 PR | 1 s ... 300 s Freely adjustable |
|
Uncertainty of measurement | | Dust concentration | ± 2 % Of measuring range full scale | Gas velocity | ± 0.1 m/s | Gas pressure | ± 1 % | Gas temperature | ± 0.5 % |
|
Process temperature | | | –20 °C ... +200 °C |
|
Process pressure | | | –70 hPa ... 10 hPa |
|
Process gas humidity | | | Non-condensing |
|
|
Ambient temperature | | | –20 °C ... +60 °C | Intake temperatures for purge air | –20 °C ... +45 °C |
|
Electrical safety | CE |
Enclosure rating | | DUSTHUNTER SP100 | IP66 | FLOWSIC100 PR | IP65 | Pressure sensor, temperature sensor | IP54 |
|
Dimensions (W x H x D) | | | 375 mm x 947 m x 1,318 mm (for details see dimensional drawings) |
|
Weight | | DUSTHUNTER SP100 | 7.8 kg | FLOWSIC100 PR | 7.2 kg | Pressure sensor | 0.2 kg | Temperature sensor | 1.3 kg |
|
Power supply | | Voltage | DUSTHUNTER SP100, FLOWSIC100 PR 24 V DC | | Pressure sensor, temperature sensor 10 V DC ... 30 V DC | Power consumption | DUSTHUNTER SP100, FLOWSIC100 PR: ≤ 70 W | | Pressure sensor, temperature sensor: ≤ 1 W |
|
All technical data can be found accompanying the individual product