- Home
- Product portfolio
- Photoelectric sensors
- Photoelectric sensors
- W12-3
- WTB12-3N1111
- Home
- Product portfolio
- Photoelectric sensors
- Photoelectric sensors
- W12-3
- WTB12-3N1111
Small photoelectric sensors
W12-3
WTB12-3N1111
1041429
Items included:
BEF-KH-W12 (2)
-
Technical details
-
Downloads
-
Accessories
-
Applications
-
Videos
-
Items supplied
-
Service and Support
-
Customs data
-
- Features
Device type Photoelectric sensors Sensor/ detection principle Photoelectric proximity sensor, Background suppression Dimensions (W x H x D) 15.6 mm x 48.5 mm x 42 mm Housing design (light emission) Rectangular Sensing range max. 20 mm ... 600 mm 1) Sensing range 20 mm ... 600 mm Type of light Infrared light Light source LED 2) Light spot size (distance) 15 mm x 15 mm (200 mm) Wave length 850 nm Adjustment Potentiometer, 5 turns - 1) Object with 90 % reflectance (referred to standard white, DIN 5033).
- 2) Average service life: 100,000 h at TU = +25 °C.
- Mechanics/electronics
Supply voltage 10 V DC ... 30 V DC 1) Ripple < 5 Vpp 2) Current consumption 55 mA 3) Switching output NPN Output function Complementary Switching mode Light/dark switching Signal voltage NPN HIGH/LOW Approx. VS / < 2.5 V Output current Imax. ≤ 100 mA Response time ≤ 330 µs 4) Switching frequency 1,500 Hz 5) Connection type Cable, 4-wire, 2 m 6) Cable material PVC Conductor cross-section 0.25 mm² Circuit protection A 7)
C 8)
D 9)
Protection class III Weight 200 g Housing material Metal Optics material Plastic, PMMA Enclosure rating IP66
IP67
IP69K
Items supplied 2 x clamps BEF-KH-W12, incl. screws Ambient operating temperature –40 °C ... +60 °C Ambient temperature, storage –40 °C ... +75 °C UL File No. NRKH.E181493 & NRKH7.E181493 - 1) Limit values when operated in short-circuit protected network: max. 8 A.
- 2) May not exceed or fall below Uv tolerances.
- 3) Without load.
- 4) Signal transit time with resistive load.
- 5) With light/dark ratio 1:1.
- 6) Do not bend below 0 °C.
- 7) A = VS connections reverse-polarity protected.
- 8) C = interference suppression.
- 9) D = outputs overcurrent and short-circuit protected.
- Safety-related parameters
MTTFD 533 years DCavg 0 % TM (mission time) 20 years
- Classifications
ECl@ss 5.0 27270904 ECl@ss 5.1.4 27270904 ECl@ss 6.0 27270904 ECl@ss 6.2 27270904 ECl@ss 7.0 27270904 ECl@ss 8.0 27270904 ECl@ss 8.1 27270904 ECl@ss 9.0 27270904 ECl@ss 10.0 27270904 ECl@ss 11.0 27270904 ETIM 5.0 EC002719 ETIM 6.0 EC002719 ETIM 7.0 EC002719 ETIM 8.0 EC002719 UNSPSC 16.0901 39121528
-
-
-
-
-