Contact
Feedback

Dx50

Measuring distances – reliable, precise and versatile
  • At a glance
    • HDDM™ technology offers best reliability, immunity to ambient light and price/performance ratio
    • Measurement ranges of 10 m or 20 m directly onto the object or even 50 m on reflector
    • Different performance levels depending on product and laser class chosen
    • Different interfaces: switching, analog or serial interface
    • Display with intuitive and consistent operating concept
    • Robust die-cast zinc metal housing
    • Operating temperature from –30 °C to +65 °C
    Your Benefits
    • Wide measurement ranges up to 10, 20 or 50 m in combination with different interfaces allow an easy and fast integration in any production environment
    • Highly reliable and precise measurement helps to increase process quality and stability
    • High measurement or switching frequencies enable a fast material flow
    • Dx50 product family is based on a common platform, offering multiple performance levels, making it easy to accommodate future changes
    • Intuitive setup via display or remote teach reduces installation time and costs
    • Temperature range from –30 °C to +65 °C allows for outdoor use without additional cooling or heating
    • Up to 40 klx ambient light immunity – allows for use in optically challenging environments
    Dx50
    Measuring distances – reliable, precise and versatile

    The Dx50 is a common distance sensor platform, offering multiple performance levels. With measurement ranges of up to 10 m or 20 m on objects or even up to 50 m when measuring on reflector, the Dx50 is suitable for many different applications. Based on a switching, analog or serial interface being available the Dx50 can easily be integrated in any application environment. Also the intuitive operating concept and a visible red laser allow a fast installation of the sensors. Thanks to the innovative HDDM technology the Dx50 provides excellent reliability, immunity to ambient light and precision when being in use. Offering an extremely good price/performance ratio the Dx50 is the right solution in many cases.

    • Technical data overview
      Measuring range

      200 mm ... 20,000 mm, 90 % remission, 18 % remission, 6 % remission

      200 mm ... 50,000 mm, on reflective tape "Diamond Grade"

      Repeatability

      5 mm / 2.5 mm 1) 2) 3)

      3 mm / 2 mm / 1 mm 1) 2) 4)

      3 mm / 2 mm 1) 3)

      0.5 mm / 0.3 mm / 0.25 mm 1) 4) 5)

      Accuracy

      ± 10 mm 6)

      ± 7 mm 6)

      ± 10 mm 7) 6)

      ± 7 mm

      ± 3 mm 8)

      Response time

      20 ms / 30 ms 3) 9)

      15 ms / 30 ms / 80 ms 4) 9)

      10 ms / 50 ms 3)

      20 ms / 100 ms 3)

      15 ms / 30 ms 3) 9)

      10 ms / 40 ms / 160 ms 4) 9)

      Data interface

      RS-422

      SSI

      Analog output1 x 0 V ... 10 V (≥ 5 kΩ)
      1 x 4 mA ... 20 mA (≤ 300 Ω)
      Switching output

      1 x PNP (100 mA) 10) 11)

      1 x NPN (100 mA) 10) 12)

      2 x PNP (100 mA) 10) 11)

      2 x NPN (100 mA) 10) 12)

      2 x / 1 x PNP (100 mA) 10) 11) 13)

      2 x / 1 x NPN (100 mA) 10) 12) 13)

      Ambient temperature

      Operation –30 °C ... +65 °C

      Storage –40 °C ... +75 °C

      Light sourceLaser, red
      Laser class2 (EN 60825-1) / 1 (EN 60825-1)
      • 1) Equivalent to 1 σ.
      • 2) 6 % ... 90 % remission.
      • 3) Dependent on the averaging setting: fast/slow.
      • 4) Dependent on the averaging setting: fast/medium/slow.
      • 5) Typical value.
      • 6) 90 % remission.
      • 7) Related to distance value on the display.
      • 8) 200 mm ... 4,000 mm: ≤ ± 5 mm.
      • 9) Lateral entry of the object into the measuring range.
      • 10) Output Q short-circuit protected.
      • 11) PNP: HIGH = VS - (< 2.5 V) / LOW = 0 V.
      • 12) NPN: HIGH = < 2.5 V / LOW = VS.
      • 13) Dependent on the set function MF: switching output 2 / laser off, external teach.
Please select your products
Show all Hide all
Filter by:
6000.0 mm 50000.0 mm

22 results:

Result 1 - 22 out of 22

1044369
Dx50
Mid range distance sensors
  • Measuring range: 200 mm ... 10,000 mm, 90 % remission, 200 mm ... 6,500 mm, 18 % remission, 200 mm ... 4,000 mm, 6 % remission
  • Response time: 20 ms / 30 ms (Dependent on the averaging setting: fast/slow) (Lateral entry of the object into the measuring range)
  • Laser class: 2 (EN 60825-1) (Wavelength: 658 nm, max. output: 180 mW, pulse duration: 5 ns, duty cycle: 1/200)
  • Multifunctional input (MF): 1 x (Response time ≤ 15ms) (PNP: HIGH = VS / LOW = ≤ 2.5 V)
  • Details
  • Compare now
1047581
Dx50
Mid range distance sensors
  • Measuring range: 200 mm ... 10,000 mm, 90 % remission, 200 mm ... 6,500 mm, 18 % remission, 200 mm ... 4,000 mm, 6 % remission
  • Response time: 20 ms / 30 ms (Dependent on the averaging setting: fast/slow) (Lateral entry of the object into the measuring range)
  • Laser class: 2 (EN 60825-1) (Wavelength: 658 nm, max. output: 180 mW, pulse duration: 5 ns, duty cycle: 1/200)
  • Multifunctional input (MF): 1 x (Response time ≤ 15ms) (PNP: HIGH = VS / LOW = ≤ 2.5 V)
  • Details
  • Compare now
1047396
Dx50
Mid range distance sensors
  • Measuring range: 200 mm ... 10,000 mm, 90 % remission, 200 mm ... 6,500 mm, 18 % remission, 200 mm ... 4,000 mm, 6 % remission
  • Response time: 20 ms / 30 ms (Dependent on the averaging setting: fast/slow) (Lateral entry of the object into the measuring range)
  • Laser class: 2 (EN 60825-1) (Wavelength: 658 nm, max. output: 180 mW, pulse duration: 5 ns, duty cycle: 1/200)
  • Multifunctional input (MF): 1 x (Response time ≤ 15ms) (NPN: HIGH = ≤ 2.5 V / LOW = VS)
  • Details
  • Compare now
1047582
Dx50
Mid range distance sensors
  • Measuring range: 200 mm ... 10,000 mm, 90 % remission, 200 mm ... 6,500 mm, 18 % remission, 200 mm ... 4,000 mm, 6 % remission
  • Response time: 20 ms / 30 ms (Dependent on the averaging setting: fast/slow) (Lateral entry of the object into the measuring range)
  • Laser class: 2 (EN 60825-1) (Wavelength: 658 nm, max. output: 180 mW, pulse duration: 5 ns, duty cycle: 1/200)
  • Multifunctional input (MF): 1 x (Response time ≤ 15ms) (NPN: HIGH = ≤ 2.5 V / LOW = VS)
  • Details
  • Compare now
1047118
Dx50
Mid range distance sensors
  • Measuring range: 200 mm ... 5,000 mm, 18 % remission, 200 mm ... 2,500 mm, 6 % remission, 200 mm ... 10,000 mm, 90 % remission
  • Response time: 20 ms / 30 ms (Dependent on the averaging setting: fast/slow) (Lateral entry of the object into the measuring range)
  • Laser class: 1 (EN 60825-1) (Wavelength: 658 nm, max. output: 120 mW, pulse duration: 2.5 ns, duty cycle: 1/400)
  • Multifunctional input (MF): 1 x (Response time ≤ 15ms) (PNP: HIGH = VS / LOW = ≤ 2.5 V)
  • Details
  • Compare now
1047616
Dx50
Mid range distance sensors
  • Measuring range: 200 mm ... 10,000 mm, 90 % remission, 200 mm ... 5,000 mm, 18 % remission, 200 mm ... 2,500 mm, 6 % remission
  • Response time: 20 ms / 30 ms (Dependent on the averaging setting: fast/slow) (Lateral entry of the object into the measuring range)
  • Laser class: 1 (EN 60825-1) (Wavelength: 658 nm, max. output: 120 mW, pulse duration: 2.5 ns, duty cycle: 1/400)
  • Multifunctional input (MF): 1 x (Response time ≤ 15ms) (PNP: HIGH = VS / LOW = ≤ 2.5 V)
  • Details
  • Compare now
1047397
Dx50
Mid range distance sensors
  • Measuring range: 200 mm ... 5,000 mm, 18 % remission, 200 mm ... 10,000 mm, 90 % remission, 200 mm ... 2,500 mm, 6 % remission
  • Response time: 20 ms / 30 ms (Dependent on the averaging setting: fast/slow) (Lateral entry of the object into the measuring range)
  • Laser class: 1 (EN 60825-1) (Wavelength: 658 nm, max. output: 120 mW, pulse duration: 2.5 ns, duty cycle: 1/400)
  • Multifunctional input (MF): 1 x (Response time ≤ 15ms) (NPN: HIGH = ≤ 2.5 V / LOW = VS)
  • Details
  • Compare now
1047617
Dx50
Mid range distance sensors
  • Measuring range: 200 mm ... 5,000 mm, 18 % remission, 200 mm ... 10,000 mm, 90 % remission, 200 mm ... 2,500 mm, 6 % remission
  • Response time: 20 ms / 30 ms (Dependent on the averaging setting: fast/slow) (Lateral entry of the object into the measuring range)
  • Laser class: 1 (EN 60825-1) (Wavelength: 658 nm, max. output: 120 mW, pulse duration: 2.5 ns, duty cycle: 1/400)
  • Multifunctional input (MF): 1 x (Response time ≤ 15ms) (NPN: HIGH = ≤ 2.5 V / LOW = VS)
  • Details
  • Compare now
1047398
Dx50
Mid range distance sensors
  • Measuring range: 200 mm ... 20,000 mm, 90 % remission, 200 mm ... 8,500 mm, 18 % remission, 200 mm ... 5,000 mm, 6 % remission
  • Response time: 15 ms / 30 ms / 80 ms (Dependent on the averaging setting: fast/medium/slow) (Lateral entry of the object into the measuring range)
  • Laser class: 2 (EN 60825-1) (Wavelength: 658 nm, max. output: 180 mW, pulse duration: 5 ns, duty cycle: 1/200)
  • Multifunctional input (MF): 1 x (Response time ≤ 15ms) (NPN: HIGH = ≤ 2.5 V / LOW = VS)
  • Details
  • Compare now
1047399
Dx50
Mid range distance sensors
  • Measuring range: 200 mm ... 13,000 mm, 90 % remission, 200 mm ... 5,800 mm, 18 % remission, 200 mm ... 3,400 mm, 6 % remission
  • Response time: 15 ms / 30 ms / 80 ms (Dependent on the averaging setting: fast/medium/slow) (Lateral entry of the object into the measuring range)
  • Laser class: 1 (EN 60825-1) (Wavelength: 658 nm, max. output: 120 mW, pulse duration: 2.5 ns, duty cycle: 1/400)
  • Multifunctional input (MF): 1 x (Response time ≤ 15ms) (PNP: HIGH = VS / LOW = ≤ 2.5 V)
  • Details
  • Compare now
1047400
Dx50
Mid range distance sensors
  • Measuring range: 200 mm ... 13,000 mm, 90 % remission, 200 mm ... 5,800 mm, 18 % remission, 200 mm ... 3,400 mm, 6 % remission
  • Response time: 15 ms / 30 ms / 80 ms (Dependent on the averaging setting: fast/medium/slow) (Lateral entry of the object into the measuring range)
  • Laser class: 1 (EN 60825-1) (Wavelength: 658 nm, max. output: 120 mW, pulse duration: 2.5 ns, duty cycle: 1/400)
  • Multifunctional input (MF): 1 x (Response time ≤ 15ms) (NPN: HIGH = ≤ 2.5 V / LOW = VS)
  • Details
  • Compare now
1047402
Dx50
Mid range distance sensors
  • Measuring range: 200 mm ... 10,000 mm, 90 % remission, 200 mm ... 6,000 mm, 18 % remission, 200 mm ... 4,000 mm, 6 % remission
  • Response time: 10 ms / 50 ms (Dependent on the averaging setting: fast/slow)
  • Laser class: 2 (EN 60825-1) (Wavelength: 658 nm, max. output: 180 mW, pulse duration: 5 ns, duty cycle: 1/200)
  • Multifunctional input (MF): 1 x (Response time ≤ 60 ms) (PNP: HIGH = VS / LOW = ≤ 2.5 V)
  • Details
  • Compare now
1047404
Dx50
Mid range distance sensors
  • Measuring range: 200 mm ... 10,000 mm, 90 % remission, 200 mm ... 6,000 mm, 18 % remission, 200 mm ... 4,000 mm, 6 % remission
  • Response time: 10 ms / 50 ms (Dependent on the averaging setting: fast/slow)
  • Laser class: 2 (EN 60825-1) (Wavelength: 658 nm, max. output: 180 mW, pulse duration: 5 ns, duty cycle: 1/200)
  • Multifunctional input (MF): 1 x (Response time ≤ 60 ms) (NPN: HIGH = ≤ 2.5 V / LOW = VS)
  • Details
  • Compare now
1047406
Dx50
Mid range distance sensors
  • Measuring range: 200 mm ... 6,000 mm, 18 % remission, 200 mm ... 4,000 mm, 6 % remission, 200 mm ... 10,000 mm, 90 % remission
  • Response time: 20 ms / 100 ms (Dependent on the averaging setting: fast/slow)
  • Laser class: 1 (EN 60825-1) (Wavelength: 658 nm, max. output: 120 mW, pulse duration: 2.5 ns, duty cycle: 1/400)
  • Multifunctional input (MF): 1 x (Response time ≤ 60 ms) (NPN: HIGH = ≤ 2.5 V / LOW = VS)
  • Details
  • Compare now
1047405
Dx50
Mid range distance sensors
  • Measuring range: 200 mm ... 10,000 mm, 90 % remission, 200 mm ... 6,000 mm, 18 % remission, 200 mm ... 4,000 mm, 6 % remission
  • Response time: 20 ms / 100 ms (Dependent on the averaging setting: fast/slow)
  • Laser class: 1 (EN 60825-1) (Wavelength: 658 nm, max. output: 120 mW, pulse duration: 2.5 ns, duty cycle: 1/400)
  • Multifunctional input (MF): 1 x (Response time ≤ 60 ms) (PNP: HIGH = VS / LOW = ≤ 2.5 V)
  • Details
  • Compare now
1047361
Dx50
Mid range distance sensors
  • Measuring range: 200 mm ... 50,000 mm, on reflective tape Diamond Grade
  • Response time: 15 ms / 30 ms (Dependent on the averaging setting: fast/slow) (Lateral entry of the object into the measuring range)
  • Laser class: 1 (EN 60825-1) (Wavelength: 658 nm, max. output: 120 mW, pulse duration: 2.5 ns, duty cycle: 1/400)
  • Multifunctional input (MF): 1 x (Response time ≤ 15ms) (PNP: HIGH = VS / LOW = ≤ 2.5 V)
  • Details
  • Compare now
1047401
Dx50
Mid range distance sensors
  • Measuring range: 200 mm ... 50,000 mm, on reflective tape Diamond Grade
  • Response time: 15 ms / 30 ms (Dependent on the averaging setting: fast/slow) (Lateral entry of the object into the measuring range)
  • Laser class: 1 (EN 60825-1) (Wavelength: 658 nm, max. output: 120 mW, pulse duration: 2.5 ns, duty cycle: 1/400)
  • Multifunctional input (MF): 1 x (Response time ≤ 15ms) (NPN: HIGH = ≤ 2.5 V / LOW = VS)
  • Details
  • Compare now
1048419
Dx50
Mid range distance sensors
  • Measuring range: 200 mm ... 50,000 mm, on reflective tape Diamond Grade
  • Response time: 10 ms / 40 ms / 160 ms (Dependent on the averaging setting: fast/medium/slow) (Lateral entry of the object into the measuring range)
  • Laser class: 1 (EN 60825-1) (Wavelength: 658 nm, max. output: 80 mW, pulse duration: 2.5 ns, duty cycle: 1/240)
  • Multifunctional input (MF): - / 1 x (Dependent on the set function MF: switching output 2 / laser off, external teach) (Response time ≤ 60 ms) (NPN: HIGH = ≤ 2.5 V / LOW = VS)
  • Details
  • Compare now
1058987
Dx50
Mid range distance sensors
  • Measuring range: 200 mm ... 50,000 mm, on reflective tape Diamond Grade
  • Response time: 10 ms / 40 ms / 160 ms (Dependent on the averaging setting: fast/medium/slow) (Lateral entry of the object into the measuring range)
  • Laser class: 1 (EN 60825-1) (Wavelength: 658 nm, max. output: 80 mW, pulse duration: 2.5 ns, duty cycle: 1/240)
  • Multifunctional input (MF): - / 1 x (Dependent on the set function MF: switching output 2 / laser off, external teach) (Response time ≤ 60 ms) (NPN: HIGH = ≤ 2.5 V / LOW = VS)
  • Details
  • Compare now
1048418
Dx50
Mid range distance sensors
  • Measuring range: 200 mm ... 50,000 mm, on reflective tape Diamond Grade
  • Response time: 10 ms / 40 ms / 160 ms (Dependent on the averaging setting: fast/medium/slow) (Lateral entry of the object into the measuring range)
  • Laser class: 1 (EN 60825-1) (Wavelength: 658 nm, max. output: 80 mW, pulse duration: 2.5 ns, duty cycle: 1/240)
  • Multifunctional input (MF): - / 1 x (Dependent on the set function MF: switching output 2 / laser off, external teach) (Response time ≤ 60 ms) (PNP: HIGH = VS / LOW = ≤ 2.5 V)
  • Details
  • Compare now
1058986
Dx50
Mid range distance sensors
  • Measuring range: 200 mm ... 50,000 mm, on reflective tape Diamond Grade
  • Response time: 10 ms / 40 ms / 160 ms (Dependent on the averaging setting: fast/medium/slow) (Lateral entry of the object into the measuring range)
  • Laser class: 1 (EN 60825-1) (Wavelength: 658 nm, max. output: 80 mW, pulse duration: 2.5 ns, duty cycle: 1/240)
  • Multifunctional input (MF): - / 1 x (Dependent on the set function MF: switching output 2 / laser off, external teach) (Response time ≤ 60 ms) (PNP: HIGH = VS / LOW = ≤ 2.5 V)
  • Details
  • Compare now
1047314
Dx50
Mid range distance sensors
  • Measuring range: 200 mm ... 20,000 mm, 90 % remission, 200 mm ... 8,500 mm, 18 % remission, 200 mm ... 5,000 mm, 6 % remission
  • Response time: 15 ms / 30 ms / 80 ms (Dependent on the averaging setting: fast/medium/slow) (Lateral entry of the object into the measuring range)
  • Laser class: 2 (EN 60825-1) (Wavelength: 658 nm, max. output: 180 mW, pulse duration: 5 ns, duty cycle: 1/200)
  • Multifunctional input (MF): 1 x (Response time ≤ 15ms) (PNP: HIGH = VS / LOW = ≤ 2.5 V)
  • Details
  • Compare now

Result 1 - 22 out of 22

TOP