- Home
- Product portfolio
- Inductive proximity sensors
- Inductive proximity sensors
- IMC
- IMC18-12NPPVC0SA00
- Home
- Product portfolio
- Inductive proximity sensors
- Inductive proximity sensors
- IMC
- IMC18-12NPPVC0SA00
Inductive proximity sensors
IMC
IMC18-12NPPVC0SA00
1079295
Items included:
BEF-MU-M18N (1)
-
Technical details
-
Downloads
-
Accessories
-
Videos
-
Items supplied
-
Service and Support
-
Customs data
-
- Features
Housing Cylindrical thread design Thread size M18 x 1 Diameter Ø 18 mm Sensing range Sn 0 mm ... 12 mm 1) Safe sensing range Sa 9.72 mm Number of switching points Up to 4 adjustable switching points or windows Switching modes Single point, Window mode, Two point mode, Visual adjustment indicator Switching frequency Qint.1 / Qint.2 on Pin2 250 Hz Installation type Non-flush Connection type Male connector M12, 4-pin 2) Switching output PNP Output Q/C Switching output or IO-Link mode Output MFC Switching output or input Output function NC / NO Output characteristic Programmable Electrical wiring DC 4-wire Enclosure rating IP68 3)
IP69K 4)
Special features Smart Task, Resistant against coolant lubricants, IO-Link Special applications Zones with coolants and lubricants, Difficult application conditions Special characteristic Resistant against coolant lubricants Pin 2 configuration External input, Teach-in, switching signal Items supplied Mounting nut, V2A stainless steel, with locking teeth (2x) - 1) Adjustable.
- 2) With gold plated contact pins.
- 3) According to EN 60529.
- 4) According to ISO 20653:2013-03.
- Mechanics/electronics
Supply voltage 10 V DC ... 30 V DC 1) Ripple ≤ 10 % Voltage drop ≤ 2 V 2) Hysteresis Programmable 3) Reproducibility ≤ 5 % 4) 5) Temperature drift (of Sr) ± 10 % EMC According to EN 60947-5-2 Continuous current Ia ≤ 200 mA 6) Short-circuit protection ✔ Reverse polarity protection ✔ Power-up pulse protection ✔ Shock and vibration resistance 100 g / 2 ms / 500 cycles; 150 g / 1 Mio cycles; 10 Hz ... 55 Hz / 1 mm; 55 Hz ... 500 Hz / 60 g Ambient operating temperature –40 °C ... +75 °C Housing material Stainless steel V2A, DIN 1.4305 / AISI 303 Sensing face material Plastic, LCP Housing length 65 mm Thread length 39 mm Tightening torque, max. Typ. 90 Nm 7) UL File No. E181493 Teach-in accuracy +/- 3% of Sr Resolution, typical (range) 40 μm (0 mm ... 8 mm)
75 μm (8 mm ... 10 mm)
150 μm (10 mm ... 12 mm)
Resolution, maximum (area) 75 μm (8 mm ... 10 mm)
150 μm (10 mm ... 12 mm)
300 μm (10 mm ... 12 mm)
- 1) IO-Link mode: 18 VDC ... 30 VDC.
- 2) At Ia max.
- 3) To comply with EN 60947-5-2, a hysteresis of approx. 10% must be set.
- 4) Ub and Ta constant.
- 5) Of Sr.
- 6) 200 mA total for both switching outputs.
- 7) Valid if toothed side of nut is used.
- Safety-related parameters
MTTFD 688 years DCavg 0 % TM (mission time) 20 years
- Communication interface
Communication interface IO-Link V1.1 Communication Interface detail COM2 (38,4 kBaud) Cycle time 5 ms Process data length 32 Bit Process data structure Bit 0 = switching signal QL1
Bit 1 = switching signal QL2
Bit 2 = switching signal QInt3
Bit 3 = switching signal QInt4
Bit 16 ... 31 = distance value
Factory setting Switching Point 1: reference value 1
Output: normally open
Pin 2 configuration: input
- Reference values
Note Reference value in Digits for switching point in mm stored in the sensor Reference value 1 12 mm Reference value 2 10 mm Reference value 3 8 mm Reference value 4 5 mm
- Reduction factors
Stainless steel (V2A, 304) Approx. 0.7 Aluminum (Al) Approx. 0.4 Copper (Cu) Approx. 0.4 Brass (Br) Approx. 0.4
- Installation note
Remark Associated graphic see "Installation" A 18 mm B 45 mm C 18 mm D 36 mm E 12 mm F 96 mm
- Smart Task
Smart Task name Base logics Logic function AND
OR
XOR
Hysteresis
Timer function On delay
Off delay
ON and OFF delay
Impulse (one shot)
Inverter Adjustable Switching frequency SIO Direct: 250 Hz 1)
SIO Logic: 250 Hz 2)
IOL: 250 Hz 3)
Switching signal Switching signal QL1 Switching output Switching signal QL2 Switching output - 1) SIO Direct: sensor operation in standard I/O mode without IO-Link communication and without using internal sensor logic or time parameters (set to "direct"/"deactivated").
- 2) SIO Logic: Sensor operation in standard I/O mode without IO-Link communication. Sensor-internal logic or timing parameters plus Automation Functions used.
- 3) IOL: Sensor operation with full IO-Link communication and usage of logic, timing and Automation Function parameters.
- Classifications
eCl@ss 5.0 27270101 eCl@ss 5.1.4 27270101 eCl@ss 6.0 27270101 eCl@ss 6.2 27270101 eCl@ss 7.0 27270101 eCl@ss 8.0 27270101 eCl@ss 8.1 27270101 eCl@ss 9.0 27270101 eCl@ss 10.0 27270101 eCl@ss 11.0 27270101 eCl@ss 12.0 27274001 ETIM 5.0 EC002714 ETIM 6.0 EC002714 ETIM 7.0 EC002714 ETIM 8.0 EC002714 UNSPSC 16.0901 39122230
-
-
-
-