Scattered light dust measuring devices
DUSTHUNTER SP100

Probe design with forward scattered light measurement

Your Benefits

  • Particularly well-suited for thick and dual-wall channels
  • Tested for suitability according to EN 15267
  • Low-maintenance thanks to self-monitoring and contamination monitoring
  • Quick installation since no alignment is required

The exact device specifications and performance data of the product may deviate from the information provided here, and depend on the application in which the product is being used and the relevant customer specifications.

Overview

Probe design with forward scattered light measurement

The DUSTHUNTER SP100 is a type-approved measuring device with probe for very low to medium dust concentrations. Installation from one side makes it ideal for thick-walled or double-walled ducts. The measurement is based on the forward scattering of light. An automated check of the zero and reference point as well as a contamination check are on board in the device.

At a glance
  • Installation from one side
  • For very low to medium dust concentrations
  • Automated check of zero and reference point
  • Contamination check
  • Hastelloy measuring probe available for corrosive gases
  • For small to medium duct diameters
  • Device version for explosive zone 2/22 or 1/21

Accessories

Spare parts

Applications

Service & Support

Technical overview

 
  • DUSTHUNTER SP100 system

    DUSTHUNTER SP100 system

    Measured valuesScattered light intensity, dust concentration (after gravimetric comparison measurement)
    Performance-tested measurandsScattered light intensity
    Measurement principlesScattered light forward
    Spectral range
    640 nm ... 660 nm
    Laser, protection class 2, power < 1 mW
    Measuring ranges
    Dust concentration0 ... 5 mg/m³ / 0 ... 500 mg/m³
    Higher measuring ranges on request
    Certified measuring ranges
    Dust concentration0 ... 7.5 mg/m³ / 0 ... 10 mg/m³ / 0 ... 15 mg/m³ / 0 ... 50 mg/m³ / 0 ... 100 mg/m³ / 0 ... 200 mg/m³ / 0 ... 500 mg/m³
    Response time (t90)
    1 s ... 600 s
    Freely adjustable
    Accuracy
    ≤ 2 %
    Of measuring range full scale
    Conformities

    Approved for plants requiring approval

    2001/80/EC (13. BImSchV)

    2000/76/EC (17. BImSchV)

    27. BImSchV

    TA-Luft (Prevention of Air Pollution)

    EN 15267

    EN 14181

    MCERTS

    2010/75/EU

    U.S. EPA PS-11 compliant

    Electrical safetyCE
    Test functions

    Automatic self-test (linearity, contamination, drift, aging)

    Contamination limit values: Warning at 30%; fault at 40%

    Manual linearity test with reference filter

  • DUSTHUNTER SP100 Ex-2K system

    DUSTHUNTER SP100 Ex-2K system

    Measured valuesScattered light intensity, dust concentration (after gravimetric comparison measurement)
    Performance-tested measurandsScattered light intensity
    Measurement principlesScattered light forward
    Spectral range
    640 nm ... 660 nm
    Laser, protection class 2, power < 1 mW
    Measuring ranges
    Dust concentration0 ... 5 mg/m³ / 0 ... 500 mg/m³
    Higher measuring ranges on request
    Certified measuring ranges
    Dust concentration0 ... 7.5 mg/m³ / 0 ... 10 mg/m³ / 0 ... 15 mg/m³ / 0 ... 50 mg/m³ / 0 ... 100 mg/m³ / 0 ... 200 mg/m³ / 0 ... 500 mg/m³
    Response time (t90)
    1 s ... 600 s
    Freely adjustable
    Accuracy
    ≤ 2 %
    Of measuring range full scale
    Conformities

    Approved for plants requiring approval

    2001/80/EC (13. BImSchV)

    2000/76/EC (17. BImSchV)

    2010/75/EU

    27. BImSchV

    TA-Luft (Prevention of Air Pollution)

    EN 15267

    EN 14181

    U.S. EPA PS-11 compliant

    Electrical safetyCE
    Test functions

    Automatic self-test (linearity, contamination, drift, aging)

    Contamination limit values: Warning at 30%; fault at 40%

    Manual linearity test with reference filter

  • DUSTHUNTER SP100 Ex-3K system

    DUSTHUNTER SP100 Ex-3K system

    Measured valuesScattered light intensity, dust concentration (after gravimetric comparison measurement)
    Performance-tested measurandsScattered light intensity
    Measurement principlesScattered light forward
    Spectral range
    640 nm ... 660 nm
    Laser, protection class 2, power < 1 mW
    Measuring ranges
    Dust concentration0 ... 5 mg/m³ / 0 ... 500 mg/m³
    Higher measuring ranges on request
    Certified measuring ranges
    Dust concentration0 ... 7.5 mg/m³ / 0 ... 10 mg/m³ / 0 ... 15 mg/m³ / 0 ... 50 mg/m³ / 0 ... 100 mg/m³ / 0 ... 200 mg/m³ / 0 ... 500 mg/m³
    Response time (t90)
    1 s ... 600 s
    Freely adjustable
    Accuracy
    ≤ 2 %
    Of measuring range full scale
    Conformities

    Approved for plants requiring approval

    2001/80/EC (13. BImSchV)

    2000/76/EC (17. BImSchV)

    27. BImSchV

    TA-Luft (Prevention of Air Pollution)

    EN 15267

    EN 14181

    2010/75/EU

    U.S. EPA PS-11 compliant

    Electrical safetyCE
    Test functions

    Automatic self-test (linearity, contamination, drift, aging)

    Contamination limit values: Warning at 30%; fault at 40%

    Manual linearity test with reference filter

  • DHSP-Txxx sender/receiver unit

    DHSP-Txxx sender/receiver unit

    Process temperature
    Standard version DHSP-T2xx–40 °C ... +220 °C
    High temperature version DHSP-T2xx–40 °C ... +400 °C
    Process pressure
    With MCU-P control unit–50 hPa ... 10 hPa
    With external purge air unit–50 hPa ... 30 hPa
    With instrument air (provided by the customer)–50 hPa ... 100 hPa
    Process gas humidity
    Non-condensing
    Duct diameter
    ≥ 0.25 m
    Ambient temperature
    –40 °C ... +60 °C
    Electrical safetyCE
    Enclosure rating
    IP66
    Dimensions (W x H x D)
    Dimensions may vary. For details, see the dimensional drawings.
    Weight
    Nominal length 435 mm≤ 6.5 kg
    Nominal length 735 mm≤ 7.8 kg
    Nominal length 1,035 mm≤ 9.5 kg
    Nominal length 1,335 mm≤ 11 kg
    Power supply
    Voltage24 V DC
    VoltageSupply via control unit
    Power consumption≤ 4 W
  • DHSP-Txxxx1EX2K sender/receiver unit

    DHSP-Txxxx1EX2K sender/receiver unit

    Process temperature
    DHSP-T2xxx1EX2K standard version–40 °C ... +220 °C
    DHSP-T4xxx1EX2K high-temperature version–40 °C ... +400 °C
    Process pressure
    With instrument air (provided by the customer)0 hPa ... 3,000 hPa
    Absolute pressure
    Process gas humidity
    Non-condensing
    Duct diameter
    ≥ 0.25 m
    Ambient temperature
    –40 °C ... +60 °C
    Ex-approvals
    IECExEx db op is IIC T6 Gb
    Ex tb op is IIIC T85°C Db
    ATEXEx II 2G Ex db op is IIC T6 Gb
    Ex II 2D Ex tb op is IIIC T85°C Db
    Electrical safetyCE, Protection class III
    Enclosure rating
    IP66
    Dimensions (W x H x D)
    Dimensions may vary. For details, see the dimensional drawings.
    Weight
    Nominal length 435 mm≤ 14 kg
    Nominal length 735 mm≤ 15.3 kg
    Power supply
    Voltage24 V DC
    VoltageSupply via control unit
    Power consumption≤ 8 W
  • DHSP-Txxxx1EX3K sender/receiver unit

    DHSP-Txxxx1EX3K sender/receiver unit

    Process temperature
    DHSP-T2xxx1EX3K standard version–40 °C ... +220 °C
    DHSP-T4xxx1EX3K high-temperature version–40 °C ... +400 °C
    Process pressure
    With instrument air (provided by the customer)–100 hPa ... 100 hPa
    Process gas humidity
    Non-condensing
    Duct diameter
    ≥ 0.25 m
    Ambient temperature
    –40 °C ... +60 °C
    Ex-approvals
    ATEXEx II 3G Ex nR op is IIC T6 Gc
    Ex II 3D Ex tc op is IIIC T85°C Dc
    Electrical safetyCE, Protection class III
    Enclosure rating
    IP66
    Dimensions (W x H x D)
    Dimensions may vary. For details, see the dimensional drawings.
    Weight
    Nominal length 435 mm≤ 13.5 kg
    Nominal length 735 mm≤ 14.8 kg
    Power supply
    Voltage24 V DC
    VoltageSupply via control unit
    Power consumption≤ 4 W
  • MCU-N control unit

    MCU-N control unit

    DescriptionUnit to control the system components and to evaluate and output the data provided by them
    Ambient temperature
    –40 °C ... +60 °C
    Electrical safetyCE, Protection class I
    Enclosure rating
    IP66
    Analog outputs1 output:
    0/2/4 ... 20 mA, 750 Ω
    Electrically isolated; two additional outputs if using I/O modules (option)
    Analog inputs2 inputs:
    0 ... 20 mA, 110 Ω
    Not electrically isolated; two additional inputs if using I/O modules (option)
    Digital outputs5 relay contacts:
    48 V, 1 A
    Potential-free; for status signals
    Digital inputs4 potential-free contacts
    Modbus✔ , ✔
    Type of fieldbus integrationTCP (via optional interface module, only one module possible per MCU)
    RTU RS-485 (via optional interface module, only one module possible per MCU)
    PROFIBUS DP
    Type of fieldbus integrationVia optional interface module (only one module possible per MCU)
    Ethernet
    Type of fieldbus integrationVia optional interface module (only one module possible per MCU)
    FunctionConnection to SOPAS ET software or OPC server
    Indication
    LC display
    Status LEDs: “Power,” “Failure,” and “Maintenance request”
    OperationVia LC-display or software SOPAS ET
    Dimensions (W x H x D)
    210 mm x 340 mm x 120 mm (for details see dimensional drawings)
    Weight
    ≤ 3.7 kg
    Power supply
    Voltage90 V AC ... 250 V AC
    VoltageVersion with 24 V DC available as an option
    Frequency47 ... 63 Hz
    Power consumption≤ 50 VA
    Options

    Interface module(s)

    I/O module(s)

  • MCU-P control unit

    MCU-P control unit

    DescriptionUnit to control the system components and to evaluate and output the data provided by them. With integrated purge air unit.
    Gas flow rate
    ≤ 20 m³/h
    Ambient temperature
    –40 °C ... +45 °C
    Intake temperatures for purge air
    Electrical safetyCE, Protection class I
    Enclosure rating
    IP66
    Analog outputs1 output:
    0/2/4 ... 20 mA, 750 Ω
    Electrically isolated; two additional outputs if using I/O modules (option)
    Analog inputs2 inputs:
    0 ... 20 mA, 110 Ω
    Not electrically isolated; two additional inputs if using I/O modules (option)
    Digital outputs5 relay contacts:
    48 V, 1 A
    Potential-free; for status signals
    Digital inputs4 potential-free contacts
    Modbus✔ , ✔
    Type of fieldbus integrationTCP (via optional interface module, only one module possible per MCU)
    RTU RS-485 (via optional interface module, only one module possible per MCU)
    PROFIBUS DP
    Type of fieldbus integrationVia optional interface module (only one module possible per MCU)
    Ethernet
    Type of fieldbus integrationVia optional interface module (only one module possible per MCU)
    FunctionConnection to SOPAS ET software or OPC server
    Indication
    LC display
    Status LEDs: “Power,” “Failure,” and “Maintenance request”
    OperationVia LC-display or software SOPAS ET
    Dimensions (W x H x D)
    300 mm x 455 mm x 220 mm (for details see dimensional drawings)
    Weight
    ≤ 13.5 kg
    Power supply
    Voltage90 V AC ... 250 V AC
    VoltageVersion with 24 V DC available as an option
    Frequency47 ... 63 Hz
    Power consumption≤ 70 VA
    Options

    Interface module(s)

    I/O module(s)

  • MCUDH Ex-3K control unit

    MCUDH Ex-3K control unit

    DescriptionUnit to control the system components and to evaluate and output the data provided by them
    Ambient temperature
    With integrated power supply unit–25 °C ... +50 °C
    With external 24 V supply–40 °C ... +60 °C
    Ex-approvals
    ATEXWith integrated power supply unit
    Without integrated power supply unit
    Ex II 3G Ex ec nA nC IIC T4 Gc
    Ex II 3D Ex tc IIIC T85°C Dc
    Ex II 3G Ex ec IIC T4 Gc
    Electrical safetyCE, Protection class I (with integrated power supply unit), Protection class III (without integrated power supply unit)
    Enclosure rating
    IP65
    Analog outputs1 output:
    0/2/4 ... 20 mA, 750 Ω
    Electrically isolated
    Analog inputs2 inputs:
    0 ... 20 mA, 110 Ω
    Not electrically isolated
    Digital outputs5 relay contacts:
    48 V, 1 A
    Potential-free; for status signals
    Digital inputs4 potential-free contacts
    Modbus
    Type of fieldbus integrationRTU RS-485 (via optional interface module, Only one module possible per MCU. Other interfaces are possible outside explosive zones using an external connection module.)
    Indication
    LC display
    Status LEDs: “Operation,” “Failure,” and “Warning”
    OperationVia LC-display or software SOPAS ET
    Dimensions (W x H x D)
    300 mm x 300 mm x 220 mm (for details see dimensional drawings)
    Weight
    ≤ 8.8 kg
    Power supply
    Voltage90 V AC ... 250 V AC
    VoltageType with external 24 V supply optionally available
    Frequency47 ... 63 Hz
    Power consumption≤ 50 VA
  • SLV4-2 purge air unit, 2BH1300, 3-ph

    SLV4-2 purge air unit, 2BH1300, 3-ph

    DescriptionUnit to provide dust-free air for flushing of optical surfaces
    Gas flow rate
    38 m³/h ... 63 m³/h
    At 30 hPa counter pressure, depending on low pressure inside the filter
    Ambient temperature
    –40 °C ... +55 °C
    Electrical safetyCE
    Enclosure rating
    IP54
    Dimensions (W x H x D)
    550 mm x 550 mm x 257 mm (for details see dimensional drawings)
    Weight
    18 kg
    Power supply
    Three-phase currentΔ: 200 ... 240 V AC, 50 Hz, 2,6 A, 400 VA
    Y: 345 ... 415 V AC, 50 Hz, 1,5 A, 400 VA
    Δ: 200 ... 275 V AC, 60 Hz, 2,6 A, 500 VA
    Y: 380 ... 480 V AC, 60 Hz, 1,5 A, 500 VA
    Δ: 270 ... 330 V AC, 50 Hz, 2,0 A, 400 VA
    Y: 465 ... 570 V AC, 50 Hz, 1,16 A, 400 VA
    Δ: 290 ... 360 V AC, 60 Hz, 2,1 A, 500 VA
    Y: 500 ... 600 V AC, 60 Hz, 1,26 A, 500 VA
    Δ: 230 V AC, 50 Hz, 2,7 A, 370 VA
    Δ: 115 V AC, 60 Hz, 3,0 A, 450 VA
    Δ: 220 ... 270 V AC, 50 Hz, 2,5 A, 400 VA
    Y: 380 ... 465 V AC, 50 Hz, 1,45 A, 400 VA
    Δ: 240 ... 290 V AC, 60 Hz, 2,6 A, 500 VA
    Y: 415 ... 500 V AC, 60 Hz, 1,55 A, 500 VA
    Auxiliary gas connections
    Purge air40 mm
    Test functionsPressure switch (switching point –35 hPa)
    Integrated components2-step air filter, type Europiclon, dust capacity 200 g
All technical data can be found accompanying the individual product

Downloads