Scattered light dust measuring devices
DUSTHUNTER SB30
Your Benefits
- Easy installation, commissioning, and operation
- Tried-and-tested measurement, not dependent on gas velocity, humidity, or particle load
- Cost-effective thanks to easy mounting on just one side; no alignment necessary
- Very low-maintenance thanks to self-monitoring
- Demand-controlled maintenance notifications

Overview
The DUSTHUNTER SB30 is a measuring device, designed to detect very low to moderate dust concentrations, such as in hot or volatile gases. Measurement is based on the tried-and-tested measurement principle of backward light scattering. Installation is easy and is only carried out on one side of the channel. Two different penetration depths are possible for adapting the measuring device to various channel diameters.
- For low to medium dust content
- Easy one-sided installation
- Automatic check of zero and reference point
- For medium to large duct diameters
Accessories
spareparts
Applications
Service & Support
Technical overview
Please note: The exact device specifications and performance data of the product may deviate from the information provided here, and depend on the application in which the product is being used and the relevant customer specifications.
- DUSTHUNTER SB30 system
DUSTHUNTER SB30 system
Measured values Scattered light intensity, dust concentration (after gravimetric comparison measurement) Measurement principles Scattered light backward Spectral range 640 nm ... 660 nm
Laser, protection class 2, power < 1 mWMeasuring ranges Scattered light intensity 0 ... 30 SI / 0 ... 3,000 SI Measuring ranges freely selectable; three measuring ranges pre-configured (0 ... 30/500/3.000 SI) Response time (t90) 1 s ... 600 s
Freely adjustable via SOPAS ET softwareAccuracy ± 2 %
Of measuring range full scaleProcess temperature –40 °C ... +600 °C Process pressure With MCU-P control unit –50 hPa ... 2 hPa With external purge air unit –50 hPa ... 30 hPa Duct diameter ≥ 500 mm Conformities TUEV type-examination
China's EPA compliant
Electrical safety CE Analog outputs 1 output:
0/2/4 ... 20 mA, 750 ΩTest functions Automatic self-test (linearity, drift, aging)
Manual linearity test with reference filter
Options MCU control unit
SCU control unit
External purge air unit
- DHSB-T30 sender/receiver unit
DHSB-T30 sender/receiver unit
Description Analyzer unit of the measuring system Ambient temperature –40 °C ... +60 °C Electrical safety CE Enclosure rating IP66 Analog outputs 1 output:
0/4 ... 20 mA, + 750 Ω
Electrically isolatedDigital outputs 3 relay contacts:
+ 48 V, 1 A
For status signalsDigital inputs 2 potential-free contacts:
For external maintenance switch, automatic self-test or linearity measurementCommunication interface Serial
CAN bus
Type of fieldbus integration RS-485 Function For connection of a MCU control unit or as service interface For connection of a SCU control unit Number 1 Dimensions (W x H x D) 265 mm x 265 mm x 295 mm (for details see dimensional drawings) Weight 7 kg Power supply Voltage 24 V Voltage Supply via MCU control unit or an external power supply Power consumption ≤ 4 W
- MCU-N control unit
MCU-N control unit
Description Unit to control the system components and to evaluate and output the data provided by them Ambient temperature –40 °C ... +60 °C Electrical safety CE Enclosure rating IP66 Analog outputs 1 output:
0/2/4 ... 20 mA, + 750 Ω
Electrically isolated; two additional outputs if using I/O modules (option)Analog inputs 2 inputs:
0 ... 20 mA
Not electrically isolated; two additional inputs if using I/O modules (option)Digital outputs 5 relay contacts:
+ 48 V, 1 A
Potential-free; for status signalsDigital inputs 4 potential-free contacts Communication interface Modbus
PROFIBUS DP
Ethernet
Type of fieldbus integration TCP (via optional interface module, only one module possible per MCU) RS-485 (via optional interface module, only one module possible per MCU) Via optional interface module (only one module possible per MCU) Function Connection to SOPAS ET software or OPC server Number 1 Indication LC display (option) Status LEDs: “Power,” “Failure,” and “Maintenance request” Operation Via LC-display (option) or software SOPAS ET Dimensions (W x H x D) 210 mm x 340 mm x 120 mm (for details see dimensional drawings) Weight ≤ 3.7 kg Power supply Voltage 90 ... 250 V Voltage Version with 24 V DC available as an option Frequency 47 ... 63 Hz Power consumption ≤ 15 W Options Interface module(s)
I/O module(s)
- MCU-P control unit
MCU-P control unit
Description Unit to control the system components and to evaluate and output the data provided by them. With integrated purge air unit. Gas flow rate ≤ 20 m³/h Ambient temperature –40 °C ... +45 °C
Intake temperatures for purge airElectrical safety CE Enclosure rating IP66 Analog outputs 1 output:
0/2/4 ... 20 mA, + 750 Ω
Electrically isolated; two additional outputs if using I/O modules (option)Analog inputs 2 inputs:
0 ... 20 mA
Not electrically isolated; two additional inputs if using I/O modules (option)Digital outputs 5 relay contacts:
+ 48 V, 1 A
Potential-free; for status signalsDigital inputs 4 potential-free contacts Communication interface Modbus
PROFIBUS DP
Ethernet
Type of fieldbus integration TCP (via optional interface module, only one module possible per MCU) RS-485 (via optional interface module, only one module possible per MCU) Via optional interface module (only one module possible per MCU) Function Connection to SOPAS ET software or OPC server Number 1 Indication LC display (option) Status LEDs: “Power,” “Failure,” and “Maintenance request” Operation Via LC-display (option) or software SOPAS ET Dimensions (W x H x D) 300 mm x 455 mm x 220 mm (for details see dimensional drawings) Weight ≤ 13.5 kg Power supply Voltage 90 ... 250 V Voltage Version with 24 V DC available as an option Frequency 47 ... 63 Hz Power consumption ≤ 70 W Options Interface module(s)
I/O module(s)
- SLV4-2 purge air unit, 2BH1300, 3-ph
SLV4-2 purge air unit, 2BH1300, 3-ph
Description Unit to provide dust-free air for flushing of optical surfaces Gas flow rate 38 m³/h ... 63 m³/h
At 30 hPa counter pressure, depending on low pressure inside the filterAmbient temperature –40 °C ... +55 °C Electrical safety CE Enclosure rating IP54 Dimensions (W x H x D) 550 mm x 550 mm x 257 mm (for details see dimensional drawings) Weight 18 kg Power supply Three-phase current Δ: 200 ... 240 V, 50 Hz, 2,6 A, 400 W Y: 345 ... 415 V, 50 Hz, 1,5 A, 400 W Δ: 200 ... 275 V, 60 Hz, 2,6 A, 500 W Y: 380 ... 480 V, 60 Hz, 1,5 A, 500 W Δ: 270 ... 330 V, 50 Hz, 2,0 A, 400 W Y: 465 ... 570 V, 50 Hz, 1,16 A, 400 W Δ: 290 ... 360 V, 60 Hz, 2,1 A, 500 W Y: 500 ... 600 V, 60 Hz, 1,26 A, 500 W Δ: 230 V, 50 Hz, 2,7 A, 370 W Δ: 115 V, 60 Hz, 3,0 A, 450 W Δ: 220 ... 270 V, 50 Hz, 2,5 A, 400 W Y: 380 ... 465 V, 50 Hz, 1,45 A, 400 W Δ: 240 ... 290 V, 60 Hz, 2,6 A, 500 W Y: 415 ... 500 V, 60 Hz, 1,55 A, 500 W Auxiliary gas connections Purge air 40 mm Test functions Pressure switch (switching point –35 hPa) Integrated components 2-step air filter, type Europiclon, dust capacity 200 g