Contact
Feedback

Long range distance sensors
Dx1000

Great performance at great distance

Your Benefits

  • Reliable distance measurement indoors and outdoors enables high system throughput
  • Multi-echo technology can suppress undesirable reflections – enabling use in a wider range of applications
  • Comprehensive options for adjustments enable perfect adaptation to the individual measuring task
  • Fast, safe commissioning using a graphical touch display, convenient SOPAS ET user interface and red alignment laser
  • A small number of device variants (standardization) accommodating a wide range of requirements keeps costs down
  • Laser class 1 and therefore eye-safe

Product selection

Show all Hide all
Filter by:
155.0 m 1500.0 m

2 results:

Result 1 - 2 out of 2

View:

1075438
Dx1000
Long range distance sensors
  • Target: Reflector
  • Measuring range: 0.2 m ... 1,500 m, on reflective tape Diamond Grade
  • Repeatability: ≥ 1 mm, See repeatability characteristic lines
  • Communication interface: Ethernet, SSI, Serial
  • Analog output: 4 mA ... 20 mA, scalable
  • Accuracy: ± 10 mm 5 m ... 50 m, ± 20 mm 0.2 m ... 2 m, ± 20 mm 50 m ... 100 m, ± 24 mm 300 m, ± 48 mm 1.500 m
  • Laser class: 1 (IEC 60825-1:2014, EN 60825-1:2014) even with simultaneous operation of measurement and alignment laser
Details
  • Compare now
1075436
Dx1000
Long range distance sensors
  • Target: Natural objects
  • Measuring range: 0.2 m ... 460 m, 90 % remission, 0.2 m ... 155 m, 6 % remission
  • Repeatability: ≥ 1 mm, See repeatability characteristic lines
  • Communication interface: Ethernet, Serial, SSI
  • Analog output: 4 mA ... 20 mA, scalable
  • Accuracy: ± 20 mm 50 m ... 100 m, ± 10 mm 0.2 m ... 50 m, ± 24 mm 100 m ... 200 m
  • Laser class: 1 (IEC 60825-1:2014, EN 60825-1:2014) even with simultaneous operation of measurement and alignment laser
Details
  • Compare now

Result 1 - 2 out of 2

Overview

Great performance at great distance

For reliable distance measurement, both indoors and outdoors: The Dx1000 long range distance sensor with infrared laser is ideal for use on cranes, for detecting vehicles in traffic applications, and for measuring hot steel slabs in a steel mill. The Dx1000 features exceptional versatility in any application – HDDM+ (High Definition Distance Measurement with multi-echo technology) enables distance measurements with high measurement accuracy, even in the presence of ambient light, rain, snow, and fog. It excels at axial object tracking and quickly detecting the edges of objects moved in from the side. The device does all this at measurement cycle times of down to one millisecond, making it ideal for use in control loops.

At a glance
  • Long range distance sensor with infrared laser featuring HDDM+ technology
  • Measures natural objects (DT1000) or reflectors (DL1000)
  • Dust-proof and waterproof housing (IP 65 and IP 67) made of highly corrosion-resistant aluminum alloy
  • Configurable digital inputs and outputs, analog output, RS-422/SSI
  • Measures hot surfaces (DT1000)

Applications

Technical overview

 
  • Technical data overview
    Measuring range

    0.2 m ... 1,500 m, on reflective tape "Diamond Grade" 1) 2) 3)

    0.2 m ... 460 m, 6 % remission, 90 % remission 1) 2) 4)

    Repeatability≥ 1 mm, See repeatability characteristic lines
    Accuracy

    ± 20 mm 0.2 m ... 2 m 5)

    ± 10 mm 5 m ... 50 m 5)

    ± 20 mm 50 m ... 100 m 5)

    ± 24 mm 300 m 5) 6)

    ± 48 mm 1.500 m 5)

    ± 10 mm 0.2 m ... 50 m 5)

    ± 24 mm 100 m ... 200 m 5)

    TargetReflector / natural objects
    Ethernet✔ , TCP/IP
    Serial✔ , RS-422
    SSI
    Measurement cycle time1 ms, 4 ms, 16 ms, 64 ms, 128 ms
    Output time≥ 1 ms 7)
    Ambient temperature operation

    –40 °C ... +55 °C 8)

    –40 °C ... +95 °C, operation with cooling case

    Ambient storage temperature–40 °C ... +75 °C
    • 1) With max. ambient light 100 kLux sunlight.
    • 2) See measuring range diagram.
    • 3) Dependent on reflector size and measuring cycle time.
    • 4) Dependent on remission and measuring cycle time.
    • 5) At T = +23 °C and after warm-up time > about 15 min.
    • 6) Add ± 2 mm per 100 m (20 ppm).
    • 7) Depending on interface used.
    • 8) At a temperature of –40 °C, a warm-up time of typ. 20 minutes is required (when supply voltage Vs = 24 V).
All technical data can be found accompanying the individual product

Downloads

TOP