Contact
Feedback

VICOTEC410

For ventilation control in road tunnels
  • At a glance
    • Automatic adjustment function (AutoAdjust)
    • Contamination check
    • Menu-driven operation via evaluation unit
    Your Benefits
    • Direct measurement, nearly without time lag
    • Low operating and maintenance costs (especially for VICOTEC411)
    • Flexible system integration with analog outputs or PROFIBUS
    VICOTEC410
    For ventilation control in road tunnels

    The VICOTEC410 product family of compact analyzers detect measurands for visibility or carbon monoxide concentrations in road tunnels:

    • VICOTEC411 for determination of visibility
    • VICOTEC412 for measurement of CO concentration
    • VICOTEC414 for the simultaneous measurement of visibility and CO concentration.

    These measurement devices request maintenance only when sensors are contaminated – reducing maintenance costs to a minimum. The VICOTEC411 monitors visibility in a tunnel and thus provides information on visibility conditions. A continuous, practically real-time control signal is used for serves for efficient ventilation control. The VICOTEC412 monitors CO pollution directly within the tunnel atmosphere. The VICOTEC414 offers a combined measurement device for simultaneous monitoring of visibility and CO concentration.

  • Please note: The exact device specifications and performance data of the product may deviate from the information provided here, and depend on the application in which the product is being used and the relevant customer specifications.

    • VICOTEC410 system
      Measured valuesVisibility (K-value), CO
      Measurement principlesTransmittance measurement, Gas filter correlation
      Length of measuring path10 m
      Measuring ranges
      Visibility (K-value)0 ... 15 km⁻¹
      CO0 ... 300 ppm
      Repeatability

      Visibility (K-value): ± 0.1 km⁻¹

      CO: ± 2 ppm

      Ambient temperature–30 °C ... +60 °C
      Storage temperature–30 °C ... +85 °C
      Electrical safetyCE
      Enclosure ratingIP65
      Analog outputs2 outputs:
      0/2/4 ... 20 mA
      Digital outputs3 relay contacts:
      125 V AC, 60 W / 150 V DC, 30 W
      Preset for failure, maintenance and alert
      Digital inputs1 input:
      5 V, 2 mA
      For external maintenance switch
      PROFIBUS DP
      Type of fieldbus integrationRS-422
      OperationMenu-driven operation via evaluation unit
      Model

      VICOTEC411 (only visibility)

      VICOTEC412 (only CO)

      VICOTEC414 (visibility and CO)

      Dimensions (W x H x D)

      190 mm x 259 mm x 539 mm (sensor, for details see dimensional drawings)

      254 mm x 349 mm x 122 mm (RCU410 evaluation unit, for details see dimensional drawings)

      125 mm x 103 mm x 57 mm (connection unit)

      163 mm x 111 mm x 57 mm (connection unit with separate power supply)

      Power supply
      Voltage190 ... 260 V AC / 95 ... 130 V AC
      Frequency50 Hz / 60 Hz
      Power consumption

      VICOTEC411: ≤ 45 W

      VICOTEC412: ≤ 80 W

      VICOTEC414: ≤ 90 W

      Corrective functionsZero point adjustment
      Test functionsReference point check

    Technical drawings

    VICOTEC410 connection unit with separate power supply
    VICOTEC410 connection unit
    RCU410 control unit
    VICOTEC410 sender/receiver unit

1 results:

VICOTEC410
Tunnel Sensors
  • Details
  • Compare now