Contact
Feedback

Flexi Loop

Cost-saving, safe sensor cascade with diagnostic function

  • At a glance
    • Ability to cascade 32 sensors with up to 100 m per segment in compliance with performance level e
    • Compatible with sensors from all manufacturers
    • Detailed diagnostics information
    • Integrated standard inputs and outputs
    • Voltage supply for sensors is included
    • Unshielded standard cable featuring M12 connectivity
    • Enclosure rating IP 65 and IP 67
    • Intelligent accessories for field diagnostics and commissioning
    Your Benefits
    • Cascading of safety switches and safety sensors with OSSD outputs minimizes the wiring effort and the number of inputs of the safety controller, which saves costs
    • Easy retrofitting of existing machines
    • Simple calculation of the performance level saves time since the Flexi Loop node monitors each sensor individually
    • User-friendly due to quick and easy configuration
    • Ability to be used over long distances increases application flexibility
    • Detailed diagnostic information minimizes system downtime
    • Seamless system integration and communication with other SICK safety controllers
    • Detailed status information on Flexi Loop components, diagnostics accessories, and safety controller enable quick and easy field diagnostics
    Flexi Loop
    Cost-saving, safe sensor cascade with diagnostic function

    The Flexi Loop can cascade up to 32 sensors while maintaining the highest performance level e. Safety switches and safety sensors with OSSD outputs can be used together regardless of the sensor manufacturer. In addition, for each sensor or switch there are detailed diagnostic information available. Integrated switching signals allow for the use of interlocks, switches and lamps. All sensors are supplied with power directly from the Flexi Loop. Unscreened standard cables are used with M12 plugs. In total Flexi Loop guarantees the highest level of security. Cascading sensors reduces the amount of wiring and the number of safety inputs in the control cabinet. It also provides a comprehensive diagnostic check of all doors, emergency stop pushbuttons and sensors. In conjunction with the Flexi Soft and the Flexi Classic, the entire safety application is able to cost-effectively meet customer needs.

    • Technical data overview
      Safety integrity level

      SIL3 (IEC 61508)

      SILCL3 (EN 62061)

      CategoryCategory 4 (EN ISO 13849)
      Performance levelPL e (EN ISO 13849)
      Suitable for

      Flexi Classic

      Flexi Soft

      Safety device connection

      For safety sensor with dual-channel OSSD outputs

      For dual-channel equivalent electro-mechanical safety switch (EMSS)

      Structure of a Flexi Loop cascade

      Modular

      1 ... 32 Flexi Loop nodes

      0 ... ∞ Flexi Loop accessory nodes

      1 Flexi Loop terminator

      Enclosure rating

      IP 65 (EN 60529)

      IP 67 (EN 60529)

      Ambient operating temperature–25 °C ... +55 °C
Please select your products
Show all Hide all
Filter by:

11 results:

Result 1 - 11 out of 11

1061710
Flexi Loop
Safe sensor cascade
  • Flexi Loop component: Node for safety sensors (OSSD)
  • Use of Flexi Loop node: For safety sensor with dual-channel OSSD outputs, With standard input, With standard output
  • Connection type safety device: Female connector M12, 8-pin
  • Details
  • Compare now
1061709
Flexi Loop
Safe sensor cascade
  • Flexi Loop component: Node for safety sensors (OSSD)
  • Use of Flexi Loop node: For safety sensor with dual-channel OSSD outputs, With standard input
  • Connection type safety device: Female connector M12, 5-pin
  • Details
  • Compare now
1061711
Flexi Loop
Safe sensor cascade
  • Flexi Loop component: Node for safety switch (EMSS)
  • Use of Flexi Loop node: For dual-channel equivalent electro-mechanical safety switch (EMSS)
  • Connection type safety device: Female connector M12, 5-pin
  • Details
  • Compare now
1061712
Flexi Loop
Safe sensor cascade
  • Flexi Loop component: Node for safety switch (EMSS)
  • Use of Flexi Loop node: For dual-channel equivalent electro-mechanical safety switch (EMSS), With standard input, With standard output
  • Connection type safety device: Female connector M12, 8-pin
  • Details
  • Compare now
1061715
Flexi Loop
Safe sensor cascade
  • Flexi Loop component: Module for energy supply
  • Description: The power supply module is used to connect a power supply with 24 V DC, for the electrical isolation and for overcurrent shutdown.
  • Details
  • Compare now
2074733
Flexi Loop
Safe sensor cascade
  • Flexi Loop component: Y-adapter
  • Description: The Flexi Loop Y-adapter (EMMS) splits the 8-pin connection of the FLN-EMSS1100108 in two 5-pin connections: One for dual-channel equivalent electro-mechanical safety switches and one for non-safe I/O signals.
  • Details
  • Compare now
2074734
Flexi Loop
Safe sensor cascade
  • Flexi Loop component: Y-adapter
  • Description: The Flexi Loop Y-adapter (OSSD) splits the 8-pin connection of the FLN-OSSD1100108 in two 5-pin connections: One for safety sensors with dual-channel OSSD outputs and one for non-safe I/O signals.
  • Details
  • Compare now
1061716
Flexi Loop
Safe sensor cascade
  • Flexi Loop component: Module to terminate cascade
  • Description: The terminator is used to terminate the safe sensor cascade on the last Flexi Loop node.
  • Details
  • Compare now
1061713
Flexi Loop
Safe sensor cascade
  • Flexi Loop component: Module for connection to Flexi Classic
  • Description: Flaxi Loop master node to connect a Flexi Loop cascade to Flexi Classic. System diagnostics during operation and during commisioning without busmaster.
  • Details
  • Compare now
1067650
Flexi Loop
Safe sensor cascade
  • Flexi Loop component: Module for connection to Flexi Classic
  • Description: Flaxi Loop master node to connect a Flexi Loop cascade to Flexi Classic. System diagnostics during operation and during commisioning without busmaster.
  • Additional interfaces: IO-Link
  • Details
  • Compare now
1061714
Flexi Loop
Safe sensor cascade
  • Flexi Loop component: Module for field diagnostics
  • Description: The diagnostics module is used as a commissioning aid and to display the Flexi Loopstates during operation.
  • Details
  • Compare now

Result 1 - 11 out of 11

safetyIQ

Discover intelligent protection for higher productivity

Learn more