Contact
Feedback

MCS100E PD

Emission monitoring of very small measuring ranges – including for HCI
  • At a glance
    • Extractive measurement of up to 8 IR-active gas components
    • Additional oxygen sensor as an option
    • Integrated permeation dryer
    • Sample gas infeed on gas sampling probe or analyzer
    • Back-purging of gas sampling probe for filter cleaning
    • Rapid measured gas exchange to minimize adsorption and desorption processes
    • Automated sample point switching
    Your Benefits
    • Especially low measurement ranges for SO2, NO, NO2 and HCl
    • Selective measurement of NO and NO2 – no converter required
    • Measurement of several gas components with one analyzer
    • Long maintenance intervals (typically 6 months) due to self monitoring of the analyzer
    MCS100E PD
    Emission monitoring of very small measuring ranges – including for HCI

    The MCS100E PD is an analyzer system for the extractive measurement of up to 8 IR active gas components. It can be supplemented with an oxygen sensor. The gas is dried by a permeation dryer, whereby HCl remains in the gas. Very small measuring ranges are possible, especially for SO2, NO, NO2, and HCl.

  • Please note: The exact device specifications and performance data of the product may deviate from the information provided here, and depend on the application in which the product is being used and the relevant customer specifications.

    • MCS100E PD system
      Measured valuesCH4, CO, CO2, H2O, HCl, N2O, NO, NO2, O2, SO2
      Performance-tested measurandsCO, CO2, HCl, NO, NO2, O2, SO2
      Measurement principlesInterference filter correlation, Gas filter correlation, Zirconium dioxide sensor
      Gas flow rate200 l/h ... 1,000 l/h
      Depending on application
      Measuring ranges
      CH40 ... 140 ppm / 0 ... 1,400 ppm
      CO0 ... 40 ppm / 0 ... 2,000 ppm
      CO20 ... 25 Vol.-% / 0 ... 100 Vol.-%
      H2O0 ... 1 Vol.-% / 0 ... 5 Vol.-%
      HCl0 ... 6 ppm / 0 ... 1,900 ppm
      NO0 ... 40 ppm / 0 ... 1,900 ppm
      NO20 ... 40 ppm / 0 ... 500 ppm
      N2O0 ... 50 ppm / 0 ... 1,000 ppm
      O20 ... 1 Vol.-% / 0 ... 21 Vol.-%
      SO20 ... 4 ppm / 0 ... 5,000 ppm
      Other measuring ranges on request
      Certified measuring ranges
      CO0 ... 50 mg/m³
      CO20 ... 25 Vol.-%
      HCl0 ... 10 mg/m³
      NO0 ... 50 mg/m³
      NO20 ... 80 mg/m³
      O20 ... 21 Vol.-%
      SO20 ... 10 mg/m³
      Response time (t90)≤ 200 s
      Depending on application
      Process temperature0 °C ... +1,300 °C
      Sample gas temperatureInlet analyzer system: 0 °C ... +220 °C
      Process pressure900 hPa ... 1,100 hPa
      Atmospheric
      Ambient temperature

      +5 °C ... +35 °C

      With cooling device: +5 °C ... +50 °C

      Ambient pressure900 hPa ... 1,100 hPa
      Conformities

      Approved for plants requiring approval

      2001/80/EC (13. BImSchV)

      2000/76/EC (17. BImSchV)

      27.BImSchV

      TA-Luft (Prevention of Air Pollution)

      EN 15267 (MCERTS)

      EN 14181:2004

      Electrical safetyCE
      Enclosure ratingIP43
      Analog outputs4 outputs:
      0/4 ... 20 mA, 500 Ω
      Max. 64 outputs with opto box via optical fibre possible
      Analog inputs4 inputs:
      0/4 ... 20 mA
      Max. 64 inputs with opto box via optical fibre possible
      Digital outputs12 outputs:
      + 40 V, 1 A
      Max. 64 outputs with opto box via optical fibre possible
      Digital inputs4 inputs:
      + 50 V AC, 4 A / 24 V DC, 4 A
      Max. 64 inputs with opto box via optical fibre possible
      Modbus
      Type of fieldbus integration

      RTU RS-232

      RTU RS-485

      TCP

      PROFIBUS DP
      RemarkOption
      Operation

      Via integrated operating unit

      Two operating levels, one password-protected

      Sequence programs can be programmed as required

      Test functions

      Automatic check cycle for zero and span point

      Internal calibration filter for QAL3 drift check without test gas (option)

      System components

      Analyzer cabinet

      Sampling probe

      Sample gas line, heated

      Options

      Zirconium dioxide sensor (oxygen measurement)

      Total hydrocarbon analyzer

    Technical drawings