- Home
- Product portfolio
- Photoelectric sensors
- Photoelectric sensors
- W12-2 Laser
- WT12L-2B540A01
- Home
- Product portfolio
- Photoelectric sensors
- Photoelectric sensors
- W12-2 Laser
- WT12L-2B540A01
Small photoelectric sensors
W12-2 Laser
WT12L-2B540A01
1018474
-
Technical details
-
Downloads
-
Accessories
-
Videos
-
Service and Support
-
Customs data
-
- Features
Sensor/ detection principle Photoelectric proximity sensor, Background suppression Dimensions (W x H x D) 15 mm x 49 mm x 41.5 mm Housing design (light emission) Rectangular Sensing range max. 30 mm ... 200 mm 1) Focus 80 mm Type of light Visible red light Light source Laser 2) Light spot size (distance) Ø 0.2 mm (80 mm) Wave length 650 nm Laser class 2 (EN 60825-1:2014, IEC 60825-1:2007) 3) Adjustment Potentiometer Special applications Detecting small objects, Detection of objects moving at high speeds Special features American version - 1) Object with 90 % reflectance (referred to standard white, DIN 5033).
- 2) Average service life: 50,000 h at TU = +25 °C.
- 3) Pulse length 4 µs, max. pulse power < 5,0 mW.
- Mechanics/electronics
Supply voltage 10 V DC ... 30 V DC 1) Ripple < 5 Vpp 2) Current consumption 55 mA 3) Switching output PNP 4)
NPN 5)
Switching mode Light switching 4)
Dark switching 5)
Switching mode selector Selectable via L/D control cable Signal voltage PNP HIGH/LOW Uv - < 2 V, Uv / 0 V, <= 1.5 V Signal voltage NPN HIGH/LOW Uv - < 2 V, Uv / 0 V, <= 1.5 V Output current Imax. ≤ 100 mA Response time ≤ 200 µs 6) Switching frequency 2,500 Hz 7) Connection type Male connector M12, 5-pin Circuit protection A 8)
C 9)
D 10)
Protection class III Weight 130 g Special device ✔ Housing material Metal Optics material Plastic, PMMA Enclosure rating IP67
IP69K
Ambient operating temperature –10 °C ... +50 °C Ambient temperature, storage –25 °C ... +75 °C UL File No. American Version, 242362, 242361 (0312012-00) - 1) Limit values when operated in short-circuit protected network: max. 8 A.
- 2) May not exceed or fall below Uv tolerances.
- 3) Without load.
- 4) 0 V or not connected, light switching.
- 5) Uv, dark switching.
- 6) Signal transit time with resistive load.
- 7) With light/dark ratio 1:1.
- 8) A = VS connections reverse-polarity protected.
- 9) C = interference suppression.
- 10) D = outputs overcurrent and short-circuit protected.
- Classifications
ECl@ss 5.0 27270904 ECl@ss 5.1.4 27270904 ECl@ss 6.0 27270904 ECl@ss 6.2 27270904 ECl@ss 7.0 27270904 ECl@ss 8.0 27270904 ECl@ss 8.1 27270904 ECl@ss 9.0 27270904 ECl@ss 10.0 27270904 ECl@ss 11.0 27270904 ETIM 5.0 EC002719 ETIM 6.0 EC002719 ETIM 7.0 EC002719 UNSPSC 16.0901 39121528
-
-
-