Measured values | Br2, CCl4, C2Cl4, CCl2F2, C3F6, CH4, C2H2, C2H4, C2H6, C3H4, C3H6, C3H8, C4H6, C4H8, C4H10, C6H6, C6H14, C7H8, CH3Cl, CH2Cl2, CHCl3, C2H3Cl, C2H2Cl2, C2H4Cl2, C2HCl3, C6H5Cl, C6H4Cl2, CHCl2F, CH3OH, C3H7OH, C2H4(OH)2, CH3CHO, HCOOH, CH3COOC2H3, C2H2O, Cl2, CO, CO2, COCl2, HCl, HCN, HF, H2O, NH3, NO, N2O, NO2, R-NCO, SO2, SiF4, many other IR / VIS active gases and liquids |
Measurement principles | Interference filter correlation, Gas filter correlation |
Spectral range | | VIS type | 300 nm ... 1,200 nm | IR type | 1,200 nm ... 12,000 nm |
|
Measuring ranges | More than 60 measuring components available (depending on concentration and sample gas composition) Up to 6 components simultanously 2 measuring ranges per component Automatic measuring range switching (adjaustable) 2 limit values per component Measuring ranges depend on application and combination of measuring components |
Response time (t90) | | | 30 s ... 120 s Adjustable |
|
Zero point drift | | VIS type | < 1 %: of smallest measuring range per day | IR type | < 2 %: of smallest measuring range per week |
|
Detection limit | | | < 2 %: relative to measuring range end value |
|
Ambient temperature | | | +5 °C ... +40 °C Temperature change maximum ±10 °C/h |
|
Storage temperature | | | –20 °C ... +60 °C |
|
Ambient humidity | | | ≤ 80 % Non-condensing |
|
Ex-approvals | | IECEx | Ex pxb IIC T3...T4 Gb | | Ex pzc IIC T3...T4 Gc | | Process cuvette: Ex eb IIC Gb | ATEX | II 2G Ex pxb IIC T4 Gb | | II 2G Ex pxb IIC T3 Gb | | Process cuvette: II 2G Ex e IIC Gb | | II 3G Ex pzc IIC T4 Gc | | II 3G Ex pzc IIC T3 Gc |
|
Electrical safety | CE |
Enclosure rating | | | IP65: measuring cuvette depending on version |
|
Analog outputs | 2 outputs: 0/4 ... 22 mA, 500 Ω Electrically isolated; max. number of outputs depends on application |
Analog inputs | 2 inputs: 0/4 ... 22 mA, 100 Ω Electrically isolated; max. number of inputs depends on application |
Digital outputs | 5 outputs: 2 power relays, electrically isolated; 3 outputs, potential-free; max. number of outputs depends on application |
Digital inputs | 4 inputs: Open contacts, potential-free; max. number of inputs depends on application |
Modbus | ✔ | Remark | Not in the Ex-version | Type of fieldbus integration | TCP |
|
Ethernet | ✔ | Remark | Not in the Ex-version | Function | Connection to SOPAS ET software or OPC server |
|
Indication | | | Status LEDs: “Power,” “Failure,” and “Maintenance request” | | LC display |
|
Input | Functional keys |
Operation | Via LC-display Via SOPAS ET software (not in Ex-type) |
Dimensions (W x H x D) | | | Dimensions may vary. For details, see the dimensional drawings. |
|
Weight | | | See dimensional drawings |
|
Material in contact with media | Measuring cuvette depending on version |
Material | Aluminium, coated |
Power supply | | Voltage | Standard version 115 V AC, ± 10 % | | Standard version 230 V AC, ± 10 % | | Ex-version 230 V AC, ± 10 % | | Ex control device 230 V AC, ± 10 % | Frequency | Analyzer: 50 ... 60 Hz | | Ex control device: 48 ... 62 Hz | Power consumption | Analyzer: ≤ 230 VA | | With cuvette heating: ≤ 805 VA | | With 2nd heating: ≤ 1,450 VA |
|
Corrective functions | Cross-sensitivity compensation of up to 6 interferents |