Vos avantages

  • Measures up to 13 gas components
  • Long maintenance interval of 6 months for many measuring components
  • Measures greenhouse gases such as N2O, CH4, and CO2
  • Measures low concentrations of HF: 0 ... 3 mg/m³

Aperçu

The all-purpose champion of meeting environmental emissions monitoring needs

The MCS100FT-C system uses Fourier infrared technology to monitor flue gas. From probe sampling to cell, all components that come in contact with the sample gas are heated to a temperature above the acid dew point to prevent corrosion. The sampling probe uses two-stage filtration, and the inlet to the analysis cell is also filtered, ensuring safe use of the system. A built-in ejector transports the sample gas without the wear that moving parts would cause, and a built-in pressure module keeps the sample gas in the cell stable. The analyzer can be used for environmental emissions monitoring and also for industrial process monitoring. An optional FID may be added to measure VOCs.

En bref
  • Touch-screen operation with multiple levels of password protection
  • Ethernet interface for remote diagnostics and operation
  • Gas paths completely heated to prevent corrosion and measurement error produced by condensation
  • Built-in ejector reduces component wear
  • Optional zirconium dioxide sensor for O2 measurement
  • Utilizes Fourier infrared technology for rapid measurement of multiple gas components
  • Supports calibration of the full system or direct calibration of the analyzer
  • Multi-stage filtration allows safe sampling
  • Automatic zeroing, span calibration, and regular back-purging
  • Includes temperature and flow control and automatic sampling cut-off if malfunction occurs
  • Automatic purging protects the instrument in case of malfunction
  • The interferometer can be unaffected by vibrations

Applications

Service & Support

Aperçu technique

 

Remarque

Les spécifications techniques et caractéristiques de performances précises peuvent varier et dépendent de l'application spécifique du client.

  • Système MCS100FT-C

    Système MCS100FT-C

    Grandeurs de mesureCH4, C2H6, C3H8, Corg, CO, CO2, HCl, HF, H2O, NH3, NO, NO2, N2O, O2, SO2, vitesse du gaz, température, pression, concentration en poussière
    Valeurs de mesure certifiées conformesCO, CO2, HCl, H2O, NO, NO2, O2, SO2, vitesse du gaz, température, pression, concentration en poussière
    Principes de mesureSpectroscopie FTIR
    Longueur de voie de mesure
    8,48 m
    Quantité d'échantillon
    ≤ 300 l/h
    Plages de mesure
    CH40 ... 50 mg/m³ / 0 ... 150 mg/m³
    C3H80 ... 55 mg/m³
    Corg0 ... 15 mg/m³ / 0 ... 500 mg/m³
    CO0 ... 75 mg/m³ / 0 ... 1.500 mg/m³
    CO20 ... 25 Vol.-%
    HCl0 ... 15 mg/m³ / 0 ... 150 mg/m³
    H2O0 ... 40 Vol.-%
    NH30 ... 10 mg/m³ / 0 ... 50 mg/m³
    NO0 ... 200 mg/m³ / 0 ... 2.000 mg/m³
    NO20 ... 100 mg/m³ / 0 ... 500 mg/m³
    N2O0 ... 50 mg/m³ / 0 ... 500 mg/m³
    O20 ... 21 Vol.-%
    SO20 ... 75 mg/m³ / 0 ... 1.500 mg/m³
    Plages de mesure certifiées
    H2O0 ... 40 Vol.-%
    NO0 ... 500 mg/m³
    O20 ... 25 Vol.-%
    SO20 ... 600 mg/m³
    Concentration en poussière0 ... 100 mg/m³
    Vitesse du gaz0 ... 40 m/s
    Temps de réglage (t90)
    ≤ 200 s
    Précision
    ≤ 2 %
    De la valeur finale de la plage de mesure
    Décalage de sensibilité
    < 3 %: de la valeur finale de la plage de mesure par intervalle de maintenance
    Décalage du point zéro
    < 0,5 %: de la valeur finale de la plage de mesure par intervalle de maintenance
    Dérive du point de référence
    ≤ ± 2 %: de la valeur finale de la plage de mesure par mois
    Limite de détection
    < 2 %: de la valeur finale de la plage de mesure
    Température de process
    ≤ +1.300 °C
    Température du gaz de mesure
    ≤ +220 °C
    Pression du process
    900 hPa ... 1.100 hPa
    Humidité du gaz de process
    Sans condensation
    Température ambiante
    +5 °C ... +35 °C
    Température de stockage
    –20 °C ... +60 °C
    Pression ambiante
    900 hPa ... 1.100 hPa
    Humidité ambiante
    ≤ 80 %
    Humidité relative ; pas de condensation
    ConformitésHJ/T 76-2007
    Indice de protection
    IP65
    Sorties analogiques4 sorties:
    0/4 ... 20 mA, + 500 Ω
    Entrées analogiques4 entrées:
    0/4 ... 20 mA
    Sorties numériques64 sorties:
    + 48 V AC, 0,5 A, 35 W / 48 V DC, 0,5 A, 24 W
    Entrées numériques64 entrées:
    + 3,9 V, 4,5 mA, 0,55 W
    Autres entréesPour la température, la pression, la vitesse du gaz et la concentration en poussière
    Affichage
    Écran LCD
    EntréeÉcran tactile
    UtilisationUtilisation à l'aide de menus avec une unité de commande
    Langues du menuAnglais
    ModèleArmoire d’analyse d’intérieur
    Dimensions (l x H x P)
    800 mm x 2.200 mm x 800 mm
    Poids
    ≤ 300 kg
    Matériau, avec contact avec le milieuPTFE, Calciumfluorid
    Alimentation en énergie
    Tension220 V AC
    Fréquence50 Hz
    ConsommationEn fonction du type et de la longueur de la conduite de gaz de mesure
    Puissance absorbéeAnalyseur: ≤ 1.000 W
    Sonde de prélèvement: ≤ 450 W
    Raccords de gaz de mesure
    Swagelok 8 mm
    Raccordements des gaz auxiliaires
    DN 6/8
    Fonctions de correctionCalibrage manuel ou automatique avec gaz d'étalon
    Fonctions de contrôleTest interne des points zéro et de référence
    Composants du système

    Analyseur

    Sonde de prélèvement

    Conduite de gaz de mesure

    Unité de commande

    Composants intégrésPompe à éjecteur
    OptionsSonde de dioxyde de zirconium (mesure de l'oxygène)
Vous trouverez toutes les caractéristiques techniques chez le produit respectif

Téléchargements

Vers le haut