In factory automation, compressed air is among the most expensive forms of energy. To save costs, you must ensure that leaks in compressed air systems are detected as quickly as possible.
The PAC50-FGG (Leakage Tester) variant provides a cost-effective solution for detecting leak in compressed air systems. Basically, the sensor monitors the pressure drop over a preset period of time. The pressure switch enables a high degree of automation while doing so: The measurements can be started either automatically via a PLC or manually. The PAC50-FGG controls a valve via the output signal, puts the system in a locked state, and shows on the display the pressure drop, the period of measurement and – if the volume of the measured system is known – also a leakage rate in L/min. Depending on the presetting of the pressure switch, a signal regarding the measured time period or the pressure difference can be output via the analog output. At the same time, the sensor also retains its function as a simple pneumatic pressure switch.