Your Benefits

  • Reliable technology and a rugged design: microScan3 Core safety laser scanners are at home in harsh industrial environments. Even in environments with dirt, dust and ambient light, the new generation of scanners shows how extremely resistant it is - thanks to the safeHDDM® scan technology, aluminum housing and well-designed fastening concept.
  • Smart integration: Low cabling costs due to standardized interfaces, fast device change due to configuration memory, and safe machine integration via networks possible
  • Intuitive operation: Easy commissioning with the Safety Designer software and diagnostic options via the display, pushbuttons, or network
  • Intelligent functions: Simultaneous protective fields, contour detection fields or measurement data output - with the help of the intelligent functions, the sensor settings can be optimally adjusted to the different requirements.

Overview

The new generation of safety laser scanners for stationary applications

The microScan3 Core provides the basis for the product family of the microScan3 safety laser scanners. It is used for the protection of stationary applications such as hazardous areas, access points and hazardous points. The innovative safeHDDM® scanning technology increases the reliability of the microScan3. It is outstanding in dust and ambient light. It increases the productivity and availability of machines. The housing is rugged. Smart connectivity facilitates safe integration into networks and cuts cabling costs. Using the Safety Designer software, the microScan3 can be intuitively configured and commissioned. The operational status can be called up and read clearly on the multicolored display or via the network. What can first impress, and repeatedly generate enthusiasm? The microScan3 from SICK.

At a glance
  • Innovative safeHDDM® scanning technology
  • Protective field range: Up to 9 m, scanning angle: 275°
  • Up to 8 freely configurable fields
  • Up to 4 simultaneous protective fields
  • System plug with configuration memory and M12 plug connectors
  • Safe machine integration via I/Os or via network with EtherNet/IP™ CIP Safety™ or PROFINET PROFIsafe
  • Safe SICK device communication via EFI-pro

Applications

Technical overview

 
  • Technical data overview

    Technical data overview

    ApplicationIndoor area
    Protective field range4 m / 5.5 m / 9 m
    Warning field range40 m / 64 m
    Scanning angle275°
    Number of fields8 / 4
    Number of monitoring cases2 / 1 / 8
    Response time

    ≥ 70 ms

    ≥ 90 ms

    ≥ 95 ms

    ≥ 115 ms

    OSSD pairs1 / 0
    Integration in the control system

    Local inputs and outputs (I/O)

    CIP Safety™ over EtherNet/IP™

    PROFINET PROFIsafe

    EFI-pro

    Performance levelPL d (EN ISO 13849)
All technical data can be found accompanying the individual product