- Home
- Product portfolio
- Automation light grids
- Measuring automation light grids
- MLG-2 ProNet
- MLG50N-1150N10501
- Home
- Product portfolio
- Automation light grids
- Measuring automation light grids
- MLG-2 ProNet
- MLG50N-1150N10501
Measuring automation light grids
MLG-2 ProNet
MLG50N-1150N10501
1216577
Usual availability on request
-
Technical details
-
Downloads
-
Accessories
-
Videos
-
Service and Support
-
Customs data
-
- Features
Version ProNet Sensor principle Sender/receiver Minimum detectable object (MDO) 50 mm, 54 mm 1) 2) 3) Beam separation 50 mm Number of beams 24 Detection height 1,150 mm Software features Q1 Presence detection Address — Baud rate RS-485 — Included with delivery 1 × sender
1 × receiver
4/6 x QuickFix brackets (6 x QuickFix brackets for monitoring heights above 2 m)
1 x mounting bracket for the fieldbus module
1 x Fieldbus module
1 × Quick Start Guide
- 1) MDO min. detectable object at high measurement accuracy.
- 2) MDO min. detectable object for standard measurement accuracy.
- 3) Depending on beam separation without cross beam setting.
- Mechanics/electronics
Light source LED, Infrared light Wave length 850 nm Supply voltage Vs DC 18 V ... 30 V 1) Power consumption sender 56.2 mA 2) Power consumption receiver 124.8 mA 2) Ripple < 5 Vpp Output current Imax. 100 mA Output load capacitive 100 nF Output load inductive 1 H Initialization time < 1 s Dimensions (W x H x D) 34 mm x 1,273.3 mm x 30.6 mm Housing material Aluminum Indication LED Enclosure rating IP65, IP67
3)Circuit protection UV connections, reverse polarity protected, Output Q short-circuit protected, Interference pulse suppression Protection class III Weight 2.647 kg Front screen PMMA Option Nonexistent - 1) Without load.
- 2) , Without load with 24 V.
- 3) Operating in outdoor condition only with a external protection housing.
- Performance
Maximum range 7 m 1) Minimum range ≥ 0 m Operating range 5 m Response time 3.6 ms 2) 3) - 1) No reserve for environmental issue and deterioration of the diode.
- 2) Without high speed.
- 3) With resistive load.
- Interfaces
Interface PROFINET
- Ambient data
EMC EN 60947-5-2 Ambient operating temperature –30 °C +55 °C Ambient storage temperature –40 °C +70 °C Ambient light immunity Direct: 150,000 lx 1)
Indirect: 200,000 lx 2)
Vibration resistance Sinusoidal oscillation 10-150 Hz 5 g Shock load Continuous shocks 10 g, 16 ms, 1000 shocks, Single shocks 15 g, 11 ms 3 per axle UL File No. NRKH.E181493 (Sensor)
NRAQ.E238799 (Fieldbus module)
- 1) Outdoor mode.
- 2) Light resistance indirect.
- Classifications
ECl@ss 5.0 27270910 ECl@ss 5.1.4 27270910 ECl@ss 6.0 27270910 ECl@ss 6.2 27270910 ECl@ss 7.0 27270910 ECl@ss 8.0 27270910 ECl@ss 8.1 27270910 ECl@ss 9.0 27270910 ETIM 5.0 EC002549 ETIM 6.0 EC002549 UNSPSC 16.0901 39121528
-
-
-