- Home
- Product portfolio
- Automation light grids
- Measuring automation light grids
- MLG-2
- MLG50S-0250D10501
- Home
- Product portfolio
- Automation light grids
- Measuring automation light grids
- MLG-2
- MLG50S-0250D10501
Measuring automation light grids
MLG-2
MLG50S-0250D10501
1213711
-
Technical details
-
Downloads
-
Accessories
-
Videos
-
Service and Support
-
Customs data
-
- Features
Device version Prime - Standard functionality Sensor principle Sender/receiver Minimum detectable object (MDO) 54 mm 1) Beam separation 50 mm Type of synchronization Optical Number of beams 6 Detection height 250 mm Software features (default) Q1 Auto-define height classification Q2 / IN Auto-define height classification Q3 Auto-define height classification inverted — Teach — key lock off Operating mode Standard ✔ Function Cross beam ✔ Beam blanking ✔ Applications Switching output Object detection
Object recognition
Height classificationData interface Object detection
Object height measurementIncluded with delivery 1 × sender
1 × receiver
4/6 x QuickFix brackets (6 x QuickFix brackets for monitoring heights above 2 m)
1 × Quick Start Guide
- 1) Depending on beam separation without cross beam setting.
- Mechanics/electronics
Light source LED, Infrared light Wave length 850 nm Supply voltage Vs DC 19.2 V ... 28.8 V 1) Power consumption sender 55.3 mA 2) Power consumption receiver 121.2 mA 2) Ripple < 5 Vpp Output current Imax. 100 mA Output load, capacitive 100 nF Output load, Inductive 1 H Initialization time < 1 s Switching output Push-pull: PNP/NPN Connection type Male connector M12, 5-pin, 0.22 m Housing material Aluminum Indication LED Enclosure rating IP65, IP67
3)Circuit protection UV connections, reverse polarity protected
Output Q short-circuit protected
Interference pulse suppression
Protection class III Weight 0.849 kg Front screen PMMA Option None UL File No. NRKH.E181493 - 1) Without load.
- 2) , Without load with 24 V.
- 3) Operating in outdoor condition only with a external protection housing.
- Performance
Maximum range 7 m 1) Minimum range ≥ 0.2 m Operating range 5 m Response time 6 ms - 1) No reserve for environmental issue and deterioration of the diode.
- Communication interface
IO-Link ✔ , IO-Link V1.1 Data transmission rate 38,4 kbit/s (COM2) Maximum cable length 20 m Cycle time 6 ms VendorID 26 DeviceID HEX 800067 DeviceID DEC 8388711 Process data length 6 Byte (TYPE_2_V) 1) Inputs/outputs 3 x Q (IO-Link) Digital output Q1 ... Q3 Number 3 Digital input In1 Number 1 - 1) With an IO-Link master with V1.0, fall back to interleaved mode (consisting of TYPE_1_1 (ProcessData) and TYPE_1_2 (On-request Data)).
- Ambient data
Shock resistance Continuous shocks 10 g, 16 ms, 1000 shocks
Single shocks 15 g, 11 ms 3 per axle
Vibration resistance Sinusoidal oscillation 10-150 Hz 5 g EMC EN 60947-5-2 Ambient light immunity Direct: 12,000 lx 1)
Indirect: 50,000 lx 2)
Ambient operating temperature –30 °C ... +55 °C Ambient temperature, storage –40 °C ... +70 °C - 1) Outdoor mode.
- 2) Light resistance indirect.
- Smart Task
Smart Task name Base logics
- Classifications
eCl@ss 5.0 27270910 eCl@ss 5.1.4 27270910 eCl@ss 6.0 27270910 eCl@ss 6.2 27270910 eCl@ss 7.0 27270910 eCl@ss 8.0 27270910 eCl@ss 8.1 27270910 eCl@ss 9.0 27270910 eCl@ss 10.0 27270910 eCl@ss 11.0 27270910 eCl@ss 12.0 27270910 ETIM 5.0 EC002549 ETIM 6.0 EC002549 ETIM 7.0 EC002549 ETIM 8.0 EC002549 UNSPSC 16.0901 39121528
-
-
-