Page Header
The product family for medium complex applications
From simple to medium complexity applications - safety interface components from SICK enable you to easily integrate safety-rated control into your machines or systems. SICK safety controllers provide cost-effective solutions for applications that use multiple safety devices.
|

Portlet 1
|
Show Content Element
|
Hide Title
|
|
|
|
Flexi Classic
|
Provides configurable logic without using any software
- Configurable - logic is implemented with rotary switches
Modular - can be expanded locally
- Supports more than 50 dual-channel safety sensors in a single system
- Reduces interconnect wiring and simplifies system design, implementation and troubleshooting
- Application-oriented function modules available
- Network diagnostics via gateway
- Free software tool: Flexi Classic Configurator
More about Flexi Classic safety controller
|
|
|
|
|

Portlet 2
|
|
|
Flexi Soft
|
Efficiently adapts to a variety of safety applications - build only what you need
- Modularly expandable (12 ... 144 inputs/outputs)
- Intuitive configuration software: easy operation, simulation mode, wiring diagrams, freely downloadable
- Configuration memory in the system plug
- Safely link up to four Flexi Soft safety controllers via EFI
- Integration into all common fieldbus systems
- Enhanced sensor functionalities via EFI interface
- 38 TÜV certified function blocks
- Flexi Soft Design Tutorial: Click here to view
More about Flexi Soft safety controller
|
|
|
|
|

Portlet 3
|
|
|
Motion Control
|
Increased productivity with safe monitoring
- Zero-speed and drive monitoring
- Variants with standstill monitoring by means of residual voltage measurement
- Clear diagnostics via the output LEDs without a software tool
- Function support via SICK's already known configuration tools
- PL e (EN ISO 13849), SIL3 (IEC 61508), SILCL 3 (EN 62061)
- Variants with a maximum input frequency of 2 kHz
- Adjustable monitoring limit/monitoring frequency from 0.1 to 9.9 Hz or 0.5 to 99 Hz
- Variants with a maximum motor supply voltage 690 V
More about Motion Control
|
|
|
|
|

Portlet 4
|
|
|
Safety remote controller UE4427/UE4457
|
- Decentralized controller in robust IP 67 enclosure rating
- For stand-alone use or in a safety network
- A standard PLC can directly operate the safe outputs on the remote controller using "Safety Enable"
- Quick and consistent shutdown time (<8 ms) even in a network, thanks to "Fast Shut Off" function
- Free Software tool: CDS
|
|
|
|
|

Portlet 5
|
|
|
UE4470
|
IP 20 safety network controller
Programmable with function blocks
Can be expanded decentrally
For stand-alone use or in a safety network
Status, diagnostic and error information can be easily accessed locally or through the network
Free Software tool: EasySCT
|
|
|
|
|