Page Header
Our analyzing systems supply application oriented solutions for measuring tasks in emission and process measurement. Thereby it is differentiated between complete "hot" measuring (MCS100E HW) and a measuring behind a cooling system to remove water vapor (MKAS systems). Typical applications for devices of the MCS100E series are emission monitoring in combustion plants and process gas monitoring in cement plants. The MKAS systems are mainly employed for emission and process monitoring in power plants and emission monitoring according to EU directives.
|

Portlet 1
|
Show Content Element
|
Show Title
|
|
|
|
MCS100E CD
|
Analyzer system with sample gas cooler
- Analyzer MCS100E, additional oxygen sensor as an option
- Integrated gas cooler
- Test gas feeding on sample gas probe
- Back-flushing of sample gas probe for cleaning of filters
- Fast sample gas exchange for minimizing adsorption and desorption effects
- Automated sample point switching
|
|
|
|
|

Portlet 2
|
|
|
MCS100E HW
|
Analyzer system with hot measurement technology
- Analyzer MCS100E, additional oxygen and total hydrocarbon analyzers as an option
- Gas paths completely heated
- Test gas feeding on sample gas probe or at analyzer
- Back-flushing of sample gas probe for cleaning of filters
- Fast sample gas exchange for minimizing adsorption and desorption effects
- Automated sample point switching
|
|
|
|
|

Portlet 3
|
|
|
MCS100E PD
|
Analyzer system with permeation dryer
- Analyzer MCS100E, additional oxygen sensor as an option
- Integrated permeation dryer
- Test gas feeding on sample gas probe
- Back-flushing of sample gas probe for cleaning of filters
- Fast sample gas exchange for minimizing adsorption and desorption effects
- Automated sample point switching
|
|
|
|
|

Portlet 4
|
|
|
MCS100FT
|
FTIR multi-component analyzing system
- Lowest type approved HF measuring range of 0 … 3 mg/m³
- Automatic spectrum adjustment via AutoVAL for very reliable measuring values
- Operation via touchscreen
- Sample gas transport by an ejector without moving parts
- Type approved according to EN 15267-3
- Remote control and diagnosis via software SOPAS-ET
- Automatic adjustment, backflushing and filter cleaning
|
|
|
|
|

Portlet 5
|
|
|
MERCEM
|
Continuous emission monitoring system for mercury
- Low detection limit
- No spectral interferences
- Reliable reduction method
- Internal calibration device as an option
- Minimized memory effects
|
|
|
|
|

Portlet 6
|
|
|
MKAS Basic
|
Analyzing system in basic configuration
- For one or two analyzers S710 or SIDOR
- Includes the basic system components
- Can be upgraded or retrofit due to modular concept
- Well-proven system components
- Wired and tested ready for use
|
|
|
|
|

Portlet 7
|
|
|
MKAS Comfort
|
Analyzing system for emission and process measurement
- For one to three analyzers S710 or SIDOR or NOx converter
- Includes the major system components
- Fulfills the requirements to an automatic measuring system according to EU standards, especially EN 15267-3
- Due to modular concept adaptable to the measuring task
- Well-proven system components
- Wired and tested ready for use
|
|
|
|
|

Portlet 8
|
|
|
MKAS Compact
|
Analyzing system for wall mounting
- For max. two analyzers S710 or SIDOR or NOx converter
- Compact analyzer cabinet
- Fulfills the requirements to an automatic measuring system according to EU standards, especially EN 15267-3
- Includes the major system components
- Due to modular concept adaptable to the measuring task
- Well-proven system components
- Wired and tested ready for use
|
|
|
|
|

Portlet 9
|
|
|
MKAS HD
|
Heavy-dusty analyzing system
- For one to three analyzers S710 or SIDOR or NOx-converter
- Includes the major system components
- Back-purgeable sampling probe
- Special filtering system including a scrubber
- Due to modular concept adaptable to the measuring task
- Well-proven system components
- Wired and tested ready for use
|
|
|
|
|

Portlet 10
|
|
|
MKAS Multipoint
|
Analyzing system with sample point switching
- For one to three analyzers S710 or SIDOR or NOx converter
- Sample point switching for two to eight measuring points
- Bypass system for switching without time lag
- Includes the major system components
- Due to modular concept adaptable to the measuring task
- Well-proven system components
- Wired and tested ready for use
|
|
|
|
|

Portlet 11
|
|
|
MKAS Twin
|
Analyzing system for parallel measurement
- For analyzers S710 or SIDOR or NOx converter
- Includes the major system components in dual layout
- Fulfills the requirements to an automatic measuring system according to EU standards, especially EN 15267-3
- Due to modular concept adaptable to the measuring task
- Well-proven system components
- Wired and tested ready for use
|
|
|
|
|

Portlet 12
|

Portlet 13
|

Portlet 14
|

Portlet 15
|

Portlet 16
|

Portlet 17
|

Portlet 18
|

Portlet 19
|

Portlet 20
|