|
|

Page Header
SICK established a new standard in dust measurement: Durable and low-maintenance systems for detecting and monitoring dust concentration. All of the dust measuring systems can be seamlessly integrated into existing measurement landscapes at your plant. Easy installation and commissioning and comfortable handling are self-evident.
|

Portlet 1
|
Show Content Element
|
Show Title
|
|
|
|
DUSTHUNTER C200
|
Dust monitor with two measuring principles
- Automatic check of zero and reference point
- Contamination monitoring
- Automatic self-alignment
- For medium to large duct diameters
- For very low to high dust concentrations
|
|
|
|
|

Portlet 2
|
|
|
FWE200
|
Extractive dust measuring system
- For very low to medium dust concentrations
- Gas sampling and return combined in one probe
- Contamination monitoring
- Automatic check cycle for zero and reference point
|
|
|
|
|

Portlet 3
|
|
|
DUSTHUNTER SB50
|
Scattered light dust monitor with backward scattering
- Automatic check of zero and reference point
- One-side installation
- Automatic compensation of background radiation, therefore no light absorber necessary
- For medium to large duct diameters
- For low to high dust concentrations
|
|
|
|
|

Portlet 4
|
|
|
DUSTHUNTER SB100
|
Scattered light dust monitor with backward scattering
- Automatic check of zero and reference point
- Contamination monitoring
- One-side installation
- Automatic compensation of background radiation, therefore no light absorber necessary
- For medium to large duct diameters
- For very low to high dust concentrations
|
|
|
|
|

Portlet 5
|
|
|
DUSTHUNTER SF100
|
Scattered light dust monitor with forward scattering
- Automatic check of zero and reference point
- Contamination monitoring
- Automatic self-alignment
- For small to medium duct diameters
- For very low to high dust concentrations
|
|
|
|
|

Portlet 6
|
|
|
DUSTHUNTER SP100
|
Scattered light dust monitor with forward scattering
- Automatic check of zero and reference point
- Contamination monitoring
- One-side installation, ideal for thick- or double-walled ducts
- For small to medium duct diameters
- For very low to high dust concentrations
|
|
|
|
|

Portlet 7
|
|
|
DUSTHUNTER T50
|
Dust concentration measuring system
- Automatic check of zero and reference point
- For small to medium measuring distances
- For medium to high dust concentrations
|
|
|
|
|

Portlet 8
|
|
|
DUSTHUNTER T100
|
Dust concentration measuring system
- Automatic check of zero and reference point
- Integrated contamination check
- For small to medium measuring distances
- For medium to high dust concentrations
|
|
|
|
|

Portlet 9
|
|
|
DUSTHUNTER T200
|
Dust concentration measuring system
- Automatic check of zero and reference point
- Integrated contamination check for sender-receiver and reflector unit
- Automatic self-alignment of the optical assembly
- For small to medium measuring distances
- For medium to high dust concentrations
|
|
|
|
|

Portlet 10
|
|
|
FW56
|
Transmission dust measuring system
- Continuous, inertialess measurement of transmission and differential transmission
- MEPA software for parameter setting and data queries
- Storage of up to 5,000 measuring values and 500 events including date and time (only FW56-I)
- Synchronized averaging to suppress exceptional interference (only FW56-I)
|
|
|
|
|

Portlet 11
|
|
|
FW100
|
Scattered light dust measuring device
- Automatic check of zero and reference point
- Monitoring of contamination
- Integrated purge-air to prevent contamination of optical surfaces
- Evaluation unit for remote control and connection of up to three FW100 devices as an option
- Device type for hazardous areas Zone 1, 2 and 22
|
|
|
|
|

Portlet 12
|
|
|
FW300
|
Laser transmissiometer
- Measuring distances from 0.5 to 15 m
- Automatic check cycle for zero and reference point
- Device type for hazardous areas Zone 1, 2 and 22
|
|
|
|
|

Portlet 13
|
|
|
OMD41
|
Transmission dust concentration monitor
- Expandable with remote control unit RCU-MS
- Remote diagnostics via modem
- Automatic contamination correction
- Automatic check cycle
- Automatic built-in linearity check
|
|
|
|
|

Portlet 14
|
|
|
RM210
|
Scattered light dust monitor
- Representative measurement also in ducts with large diameters
- Cyclic monitoring of zero and reference point
- Automatic monitoring of contamination and correction
- Data remote access via modem possible
- Easy to perform linearity measurement
|
|
|
|
|

Portlet 15
|
|
|
RM230
|
Scattered light dust monitor with AutoRANGE
- Automatische Messbereichseinstellung
- Integrierte automatische Lineritätsmessung
- Drei vordefinierte Kalibrierfunktionen im Gerät hinterlegt
- Zyklische Überwachung von Null- und Referenzpunkt
- Representative Messung auch bei Kanälen mit großen Durchmessern
- Automatische Verschmutzungsüberwachung und -korrektur
- Datenfernübertragung über Modem möglich
|
|
|
|
|

Portlet 16
|
|
|
SHC500
|
Gravimetric dust concentration measuring device
- No dust loss due to patented sampling system
- Automatic data recording and system control
- Isokinetic control in real time
- Automatic storage and evaluation of the measuring values
- Automatic measurement of the flow angle and detection of turbulence effects
|
|
|
|
|

Portlet 17
|

Portlet 18
|

Portlet 19
|

Portlet 20
|