FLOWSIC100 Series 

Volume Flow Measuring Devices FLOWSIC100 Series 
Thanks to its modular design, the FLOWSIC100 series can be used in many applications.
 
Emissions monitoring
Continuous, non-contact, and direct – the FLOWSIC100 Emission devices supply accurate and reliable measurements of the volume flow and gas velocity in flue-gas, exhaust-gas ducts or chimneys. They fulfill the requirements of the German Clean Air Regulations and the Federal German Pollution Control Act (13th, 17th and 27th Impl. Ordinances).
 
Process measurement
The reliability, precision, and short response times of the FLOWSIC100 Process series significantly enhance the efficiency of open and closed-loop control circuits. The instantaneous flow measurement reflect the current process status - even under difficult conditions, such as high temperatures or pressures.
 
Flare gas measurement
For FLOWSIC100 Flare an innovative sensor design was developed. The ultrasonic transducer is embedded in a flow optimized sensor shape - qualified for high speed gas conditions. The unique design reduces flow noise and signal drift to a minimum and enables stable and reliable results at very high gas velocities.

The selection table 

  
Product type Inner diameter of duct Gas temperature Process pressure
Process measurement
 FLOWSIC100 CL150 0.15 ... 1.7 m  -40 ... 260 °C 0 ... 16 bar
 FLOWSIC100 EX-CL150 0.15 ... 1.7 m -40 ... 260 °C 0 ... 16 bar
 FLOWSIC100 EX-CL150-RE 0.15 ... 1.7 m -40 ... 260 °C 0 ... 16 bar
 FLOWSIC100 EX-PN16 0.15 ... 1.7 m -40 ... 260 °C 0 ... 16 bar

 FLOWSIC100 EX-PN16-RE

0.15 ... 1.7 m -40 ... 260 °C 0 ... 16 bar
 FLOWSIC100 EX-Z2-CL150 0.15 ... 1.7 m -40 ... 260 °C 0 ... 16 bar
 FLOWSIC100 EX-Z2-CL150-RE 0.15 ... 1.7 m -40 ... 260 °C 0 ... 16 bar
 FLOWSIC100 EX-Z2-PN16 0.15 ... 1.7 m -40 ... 260 °C 0 ... 16 bar
 FLOWSIC100 EX-Z2-PN16-RE 0.15 ... 1.7 m -40 ... 260 °C 0 ... 16 bar
FLOWSIC100 PN16 0.15 ... 1.7 m -40 ... 260 °C 0 ... 16 bar
FLOWSIC100 PR-EX-Z2 > 0.4 m -40 ... 260 °C -100 ... 100 hPa
Flare gas measurement
FLOWSIC100 EX 0.1 ... 1.8 m -70 ... 280 °C -0.5 ... 16 bar
FLOWSIC100 EX-PR 0.3 ... 1.8 m -70 ... 280 °C -0.5 ... 16 bar
FLOWSIC100 EX-S 0.1 ... 1.8 m -70 ... 280 °C -0.5 ... 16 bar
Emission measurement
 FLOWSIC100 H 1.4 ... 13 m  -40 ... 260 °C -100 ... 100 hPa
 FLOWSIC100 H-AC 1.4 ... 13 m  -40 ... 450 °C -100 ... 100 hPa
 FLOWSIC100 M  0.15 ... 3.4 m  -40 ... 260 °C -100 ... 100 hPa
 FLOWSIC100 M-AC  0.15 ... 3.4 m  -40 ... 450 °C -100 ... 100 hPa
 FLOWSIC100 PH  0.7 ... 8.7 m  -40 ... 450 °C -100 ... 100 hPa
 FLOWSIC100 PH-S 1.4 ... 11.3 m  -40 ... 450 °C -100 ... 100 hPa
 FLOWSIC100 PM  0.35 ... 2.5 m  -40 ... 450 °C -100 ... 100 hPa
 FLOWSIC100 PR > 0.4 m  -40 ... 260 °C -100 ... 100 hPa
 FLOWSIC100 PR-AC > 0.4 m  -40 ... 350 °C -100 ... 100 hPa
 FLOWSIC100 S  0.15 ... 1.3 m  -40 ... 150 °C -100 ... 100 hPa